en:controller:setup [2021/10/15 17:25]
dmitry [Statistics]
en:controller:setup [2023/04/05 15:23]
dmitry [Logger]
Line 1: Line 1:
 ~~Title: Controller setup~~ ~~Title: Controller setup~~
  
-====== Important! ====== +====== Controller (v.0.8.7) ======
- +
-Before reading the instructions, check which firmware is installed in your controller in the **Controller** > **Device information** menu item **Firmware ver.** \\ +
-  * [[en:controller:setup#controller_v07|Instructions for firmware up to v0.7 inclusive]]. +
-  * [[en:controller:setup#controller_v08|Instructions for firmware v0.8 or higher]]. +
- +
- +
-====== Controller (v.0.7) ======+
  
 The controller allows you to control BLDC (Brushless Direct Current Motor) and PMSM (Permanent Magnet Synchronous Motor) electric motors. At the moment we are producing three types of controllers for different motors power. The controller allows you to control BLDC (Brushless Direct Current Motor) and PMSM (Permanent Magnet Synchronous Motor) electric motors. At the moment we are producing three types of controllers for different motors power.
Line 15: Line 8:
  
 ^  Parameters  ^  Controller 6F v.2  ^  Controller 12F  ^  Controller 24F  | ^  Parameters  ^  Controller 6F v.2  ^  Controller 12F  ^  Controller 24F  |
-^Maximum power|  4 000W  |  10 000W  |  20 000W  |+^Maximum power|  4 000W  |  12 000W  |  27 000W  |
 ^Nominal power|  2 000W  |  5 000W  |  10 000W  | ^Nominal power|  2 000W  |  5 000W  |  10 000W  |
-^Voltage range|  20-90V  |||+^Voltage range|  30-90V  |||
 ^Phase current, max|  120A  |  250А  |  500А  | ^Phase current, max|  120A  |  250А  |  500А  |
-^Battery current, max|  ~90A  |  ~150A  |  ~300A  |+^Battery current, max|  90A  |  150A  |  350A  |
 ^Supply out|  12В 3A  ||| ^Supply out|  12В 3A  |||
 ^Operating temperature range|  -30°C до 80°C  ||| ^Operating temperature range|  -30°C до 80°C  |||
Line 30: Line 23:
 ^Sleep current less|  <300uA  ||| ^Sleep current less|  <300uA  |||
 ^Protection class|  IP57 (IP67 with compound)  ||| ^Protection class|  IP57 (IP67 with compound)  |||
-^Size, without wires|   53х32х91 mm  |  86х43х125 mm  |  86х43х185 mm  |+^Size, without wires|  53х32х91 mm  |  86х43х125 mm  |  85х42х170 mm  |
 ^Weight|  280g (with compound 430g)  |  640g (with compound 890g)  |  1100g (with compound 1450g)  | ^Weight|  280g (with compound 430g)  |  640g (with compound 890g)  |  1100g (with compound 1450g)  |
 ^Warranty|  2 years (with compound potting — 3 year)  ||| ^Warranty|  2 years (with compound potting — 3 year)  |||
Line 36: Line 29:
 //In the kit: // //In the kit: //
  
-  * CAN-cable 1,2-meters length for connection to the On-board Computer.\\ +   * CAN-cable 1,2-meters length for connection to the On-board Computer. 
-  * Phase wires.\\ +  * Phase wires. 
-  * Battery wires\\+  * Battery wires
   * Hall sensors wire.   * Hall sensors wire.
  
Line 45: Line 38:
 //Optionally you can order:// //Optionally you can order://
  
-  * САN-cables 0,3 and 2 meters length.\\ +  * САN-cables 0,3 and 2 meters length. 
-  * Controller-side inputs for connection throttle, brakes levers directly to the Controller.\\ +  * Controller-side inputs for connection throttle, brakes levers directly to the Controller. 
-  * PWM/PAS wire for connection PAS, fans for cooling or brake lights.\\+  * PWM/PAS wire for connection PAS, fans for cooling or brake lights. 
  
 ===== Connection diagram ===== ===== Connection diagram =====
Line 55: Line 49:
 When the power is turned on for the first time, the controller will start automatically. To enable/disable the controller, you must connect an external switch according to the diagram or configure the button located on the back of the On-board computer in the menu **Devices** > **Controller** > **Extra parameters** > **Disable button**.\\ When the power is turned on for the first time, the controller will start automatically. To enable/disable the controller, you must connect an external switch according to the diagram or configure the button located on the back of the On-board computer in the menu **Devices** > **Controller** > **Extra parameters** > **Disable button**.\\
  
-You can find the wiring diagrams of the other devices on this [[https://drive.google.com/file/d/1KkEgWcJ5U-AEkk6GrXhDNlYXFCcsjpUQ/view|link]]. By default, all peripherals (throttle, brake, switches, etc.) are connected into ports located on the backside of **[[en:display:start|On-board computer]]**. To access the ports, you need to unscrew five screws and remove the plastic cover. For connection, use PHD 2.0 connectors and crimp pins, which are included in the kit. If you do not have a crimping tool such as Crimper SN-2549, you must order "Crimped wires for display". The On-board computer is connected to the controller with one CAN-wire 1.2 meters long, which is included in the controller kit. Be careful, the CAN-wire from the Controller is connected to the **SYSTEM** connector on the backside of the On-board computer.+You can find the wiring diagrams of the other devices on this [[https://bit.ly/3zPIYvn|link]]. By default, all peripherals (throttle, brake, switches, etc.) are connected into ports located on the backside of **[[en:display:start|On-board computer]]**. To access the ports, you need to unscrew five screws and remove the plastic cover. For connection, use PHD 2.0 connectors and crimp pins, which are included in the kit. If you do not have a crimping tool such as Crimper SN-2549, you must order "Crimped wires for display". The On-board computer is connected to the controller with one CAN-wire 1.2 meters long, which is included in the controller kit. Be careful, the CAN-wire from the Controller is connected to the **SYSTEM** connector on the backside of the On-board computer.
  
 If you want to connect peripherals directly to the Controller, you need to order "Control-side inputs", in the diagram below this switching option is designated as "Alternative connection". You can also use a mixed connection, for example, connect the throttle lever to the On-board computer, and the brake lever to the Controller.\\ \\ If you want to connect peripherals directly to the Controller, you need to order "Control-side inputs", in the diagram below this switching option is designated as "Alternative connection". You can also use a mixed connection, for example, connect the throttle lever to the On-board computer, and the brake lever to the Controller.\\ \\
Line 95: Line 89:
 ===== Auto-setup ===== ===== Auto-setup =====
  
-The auto-setup function in the **Controller** > **Auto-setup** menu section allows you to automatically set up the electric motor, throttle, and brake levers.+The auto-setup function in the **Controller** > **Auto-setup** menu section allows you to automatically set up the electric motor, throttle, and brake levers. If the throttle and brake levers are connected to the On-board computer, then they must be configured in [[en:display:start#control_setup|section]] menu **On-board computer** > **Control setup**. In this case, when starting the function **Full setup**, you must skip the menu items **Brake** and **Throttle** (they will be detected as an error anyway) or you can not start **Full setup** and activate each setup menu item manually starting with **Motor LR**, then **Motor** and **Angle correction**. If you have an electric motor without a temperature sensor, then you need to disable it in [[en:controller:setup#motor_temperature_sensor|menu]] section **Controller** > **Motor setup** > **Motor t°-sensor** > **Sensor type**. If this is not done, then auto-setup of the motor will show an error (Timeout).
  
-{{:en:controller:k22_en.png?nolink }}+{{:en:controller:1_0.8.png?nolink }}
  
 The auto-setup menu starts the subprogram and shows only the process. All settings are saved under **Controller** > **Motor setup**. After restarting the Controller, all switches will be in the **Off** position. The auto-setup menu starts the subprogram and shows only the process. All settings are saved under **Controller** > **Motor setup**. After restarting the Controller, all switches will be in the **Off** position.
Line 111: Line 105:
 If you have a throttle lever and an analog brake connected, then you need to enable Full Setup, and follow the instructions on the On-Board computer screen. The corresponding menu items will indicate when to press and release the throttle or brake lever. If you have a throttle lever and an analog brake connected, then you need to enable Full Setup, and follow the instructions on the On-Board computer screen. The corresponding menu items will indicate when to press and release the throttle or brake lever.
  
-If only one throttle lever is connected, you must independently turn on the items step-by-step: Throttle, Motor, Angle correction. When you enable each of the menu items, the hints will be displayed.+If only one throttle lever is connected, you must independently turn on the items step-by-step: **Throttle****Motor LR****Motor**, **Angle correction**. When you enable each of the menu items, the hints will be displayed. Auto-setup function **Motor LR** detects the inductance and resistance of the motor. You can see the measurement results in the menu section **Controller** > **Motor setup**, items **Phase resistance**, **Inductance d** and **Inductance q**.
  
 If the motor is heavy and autodetect does not happen, you can gently push it with your hand or increase the tuning current in the **Controller** > **Auto-setup** > **Setup current** section, for example, twice. The setup current can be selected in the range from **2A** to **50A**, in increments of **1A**. If the motor is heavy and autodetect does not happen, you can gently push it with your hand or increase the tuning current in the **Controller** > **Auto-setup** > **Setup current** section, for example, twice. The setup current can be selected in the range from **2A** to **50A**, in increments of **1A**.
Line 121: Line 115:
 ===== Firmware update ===== ===== Firmware update =====
  
-In the menu section **Controller** > **Settings and Update**, you can update the Controller's firmware, reset settings, import or export a configuration. You can upload all controller settings to a microSD card. The created file with the name **NCconf.cfg** - **NCconf9.cfg** you can open with the "Notepad" program, see all your settings, make any changes, save. Likewise, you can import a previously saved configuration into the Controller. Trip computer settings cannot be exported or imported.+In the menu section **Controller** > **Update and Settings**, you can update the Controller's firmware, reset settings, import or export a configuration. You can upload all controller settings to a microSD card. The created file with the name **NCconf.cfg** - **NCconf9.cfg** you can open with the "Notepad" program, see all your settings, make any changes, save. Likewise, you can import a previously saved configuration into the Controller. Trip computer settings cannot be exported or imported. On-board computer settings can be exported and imported in separate [[en:display:start#import_and_export_of_settings|sections]] of the Onboard computer menu. This function is only available in the On-board computer firmware version **0.7B** and higher.
  
 {{:en:controller:k3_en.png?nolink |}} {{:en:controller:k3_en.png?nolink |}}
Line 142: Line 136:
 ==== Modes setup ==== ==== Modes setup ====
  
-{{:en:controller:k4_en.png?nolink |}}+{{:en:controller:9_0.8.png?nolink |}}
  
 The ** # Current mode ** line displays the currently selected control mode. List of possible options: \\ The ** # Current mode ** line displays the currently selected control mode. List of possible options: \\
Line 158: Line 152:
 **Power** — maximum power (discharge) of the battery, in kilowatts (**kW**). Select of values from **0.00kW** to **30.0kW**, in increments of **0.1kW**. Set to 0.0kW to disable the power limiting limit.\\ **Power** — maximum power (discharge) of the battery, in kilowatts (**kW**). Select of values from **0.00kW** to **30.0kW**, in increments of **0.1kW**. Set to 0.0kW to disable the power limiting limit.\\
  
-**Speed** — maximum speed in percentage (%). Select of values from **4%** to **150%**, in increments of **2%**. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en:controller:setup#speedometer_setup|Speedometer setup]]**). A speed value over 100% activates the field weakening mode, which allows the motor to accelerate above the supply voltage(see section **[[en:controller:setup#field_weakening_setup|Field weakening setup]]**).\\+**Speed** — maximum speed in percentage (%). Select of values from **4%** to **150%**, in increments of **2%**. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en:controller:setup#speedometer_setup|Speedometer setup]]**). A speed value over 100% activates the field weakening mode, which allows the motor to accelerate above the supply voltage (see section **[[en:controller:setup#field_weakening_setup|Field weakening setup]]**).\\
  
 ==== Electric brake setup ==== ==== Electric brake setup ====
  
-**Braking phase** — the value of the phase current of braking by the motor, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. For braking to zero, it is recommended to enable **Active braking** in the section **Controller** > **Control**. When using the switch brake, lower brake current change speed makes recuperation more smooth. \\+**Braking phase** — the value of the phase current of braking by the motor, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. For braking to zero, it is recommended to enable **Active braking** in the section **Controller** > **Control**. When using limit switches on mechanical brakes, lower brake current change speed makes recuperation more smooth. \\
  
 ==== Braking phase at speed control ==== ==== Braking phase at speed control ====
Line 172: Line 166:
 In the menu item **Controller** > **Control** > **Speed lim. at 0% throttle** enable the speed limit at 0% throttle (optional), enable if you need braking with completely released throttle. \\ In the menu item **Controller** > **Control** > **Speed lim. at 0% throttle** enable the speed limit at 0% throttle (optional), enable if you need braking with completely released throttle. \\
  
 +==== Regenerative braking setting ====
 +
 +**Braking ph. at 0% throttle** — phase braking current with the throttle handle released, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. \\
 +
 +This function will be active if additional modes are disabled in the **Controller** > **Advanced modes** menu section or if, with activated additional modes, in one of the menu sections **Mode S1**, **Mode S2** or **Mode S3** in menu item **Braking ph. at 0% throttle** was setup is **0A**.
 ==== Reverse setup ==== ==== Reverse setup ====
  
Line 181: Line 180:
 ==== Field weakening setup ==== ==== Field weakening setup ====
  
-**Field weakening** — the magnitude of the field weakening current, in Amperes (**A**). Select of values from **0A** to **500A**,  in increments of **2A**. This setting allows you to increase the maximum motor speed and depends on the supply voltage, in any case, the speed will be no more than the maximum supply voltage (**Vmax**) of the controller (**95V limit**).\\ +**Field weakening** — the magnitude of the field weakening current, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. This setting allows you to increase the maximum motor speed and depends on the supply voltage, in any case, the speed will be no more than the maximum supply voltage (**Vmax**) of the controller (**95V limit**).<WRAP center round info 60%> 
- +The current of weakening creates a field that acts against the field of the permanent magnets. The superposition of these fields creates an equivalent field that is below nominal. The attenuation efficiency depends on the parameters of the motor. The best results can be obtained with IPM motors. </WRAP> 
-<WRAP center round info 60%>\\ +\\ 
-The current of weakening creates a field that acts against the field of the permanent magnets. The superposition of these fields creates an equivalent field that is below nominal. The attenuation efficiency depends on the parameters of the motor. The best results can be obtained with IPM motors. +<WRAP center round warning 60%>Warning! High Field weakening setting may damage your motor! It is not recommend to exceed 500Hz on a rotor for most 0.35mm steel motors</WRAP>
-</WRAP>\\+
  
 To set up the weakening, you need: To set up the weakening, you need:
-  * for one of the control modes in the section **Controller** > **Control modes** specify a speed value greater than 100%, for example, Speed 3 is 120%. 
-  * set the weakening current value in the section **Controller** > **Control modes**, you can start from 30A.\\ 
  
-Field weakening is activated when the maximum speed is reached, the Controller adds weakening current, limiting the phase current and weakening current specified in the control mode. That is if the effective phase current is 70A, and the weakening current is set to 30A, then a minimum of 100A must be specified in the phase current settings. If the phase current increases to 80A, then only 20A will remain for weakening because 80A + 20A = 100A.\\+  * for one of the control modes in the section **Controller**  > **Control modes**  specify a speed value greater than 100%, for example, Speed 3 is 120%. 
 +  * set the weakening current value in the section **Controller**  > **Control modes**, you can start from 30A. 
 + 
 +Field weakening is activated when the maximum speed is reached, the Controller adds weakening current, limiting the phase current and weakening current specified in the control mode. That is if the effective phase current is 70A, and the weakening current is set to 30A, then a minimum of 100A must be specified in the phase current settings. If the phase current increases to 80A, then only 20A will remain for weakening because 80A + 20A = 100A. 
 + 
 +Also, the Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery). If the motor starts twitching on the suspended wheel, then it is necessary to reduce the weakening current.
  
-Also, the Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery). If the motor starts twitching on the suspended wheel, then it is necessary to reduce the weakening current.\\ 
  
 ==== Current change speed ==== ==== Current change speed ====
Line 213: Line 213:
  
 In the menu **Controller** > **Advanced modes** > **Neutral by default** you can activate the neutral mode (N) when the controller starts up, which will be active until one of the speed modes is activated. In a neutral mode, only the electric brake operates, throttle and PAS are disabled. This mode is recommended for use with speed buttons (not a switch). The function does not work with a 3-position switch (functions of the S1of3 and S3of3 ports in the **Controller** > **I/O configuration** menu). ​\\ In the menu **Controller** > **Advanced modes** > **Neutral by default** you can activate the neutral mode (N) when the controller starts up, which will be active until one of the speed modes is activated. In a neutral mode, only the electric brake operates, throttle and PAS are disabled. This mode is recommended for use with speed buttons (not a switch). The function does not work with a 3-position switch (functions of the S1of3 and S3of3 ports in the **Controller** > **I/O configuration** menu). ​\\
 +~~CL~~ \\
  
 Each mode has its own section in the **Controller** > **Advanced modes** > **Mode S1, Mode S2, Mode S3 ** with the following settings: \\ Each mode has its own section in the **Controller** > **Advanced modes** > **Mode S1, Mode S2, Mode S3 ** with the following settings: \\
  
-{{:en:controller:k6_en.png?nolink |}}+{{:en:controller:5_0.8.png?nolink |}}
 **Throttle mode** — selection of the operating mode of the throttle lever, read more in the section **[[en:controller:setup#throttle_control_mode_setup|Throttle control mode setup]]**.\\ **Throttle mode** — selection of the operating mode of the throttle lever, read more in the section **[[en:controller:setup#throttle_control_mode_setup|Throttle control mode setup]]**.\\
  
 **Acceleration lim.** and **Deceleration lim.** — are specified in ERPM/s, select of values from **0 ERPM/s** to **500000 ERPM/s**, in increments of **200 ERPM/s **. These settings allow you to limit the speed of acceleration or deceleration of the motor, it is convenient to use on slippery surfaces. For setting go to the **Controller** > **Status flags** section, in this menu there are two parameters that register the maximum acceleration and deceleration — **Max acceleration** and **Max deceleration**. **Reset** the values of these parameters in the same section of the menu, then you need to ride your e-bike in order to register the current dynamics of acceleration and deceleration. You can use these values as a reference and decrease them if you need to limit change speed. If the type of surface changes, for example, it becomes too slippery, then these values can be reduced until it becomes comfortable to catch the moment when the wheel loses traction. \\ **Acceleration lim.** and **Deceleration lim.** — are specified in ERPM/s, select of values from **0 ERPM/s** to **500000 ERPM/s**, in increments of **200 ERPM/s **. These settings allow you to limit the speed of acceleration or deceleration of the motor, it is convenient to use on slippery surfaces. For setting go to the **Controller** > **Status flags** section, in this menu there are two parameters that register the maximum acceleration and deceleration — **Max acceleration** and **Max deceleration**. **Reset** the values of these parameters in the same section of the menu, then you need to ride your e-bike in order to register the current dynamics of acceleration and deceleration. You can use these values as a reference and decrease them if you need to limit change speed. If the type of surface changes, for example, it becomes too slippery, then these values can be reduced until it becomes comfortable to catch the moment when the wheel loses traction. \\
 +
 +**Braking phase** — the value of the phase current of braking by the motor, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. For braking to zero, it is recommended to enable Active braking in the section **Controller** > **Control**. When using limit switches on mechanical brakes, lower brake current change speed makes recuperation more smooth.
 +
 +**Braking ph. at 0% throttle** — phase braking current with the throttle handle released, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. If **0A** is specified or additional modes are disabled in the **Controller** > **Advanced modes** section of the menu, then for the recuperation level will be used value from menu item in the **Controller** > **Control modes** > **Braking ph. at 0% throttle** menu item. 
  
 **Revers** — reverse gear activation when the control mode is selected. Select of values **On** or **Off**. \\ **Revers** — reverse gear activation when the control mode is selected. Select of values **On** or **Off**. \\
Line 385: Line 390:
 ==== Throttle control mode setup ==== ==== Throttle control mode setup ====
  
-The menu item **Controller** > **Control** > **Throttle modes** you can set up throttle lever mode.+The menu item **Controller** > **Control** > **Throttle mode** you can set up throttle lever mode.
  
-{{:en:controller:k12_en.png?nolink |}}+{{:en:controller:6_0.8.png?nolink |}}
  
 Three throttle modes options are available:\\ Three throttle modes options are available:\\
Line 399: Line 404:
 The menu items in the **Controller** > **Control** section allow you to set the voltage ranges of the throttle and brake grips. \\ The menu items in the **Controller** > **Control** section allow you to set the voltage ranges of the throttle and brake grips. \\
  
-{{:en:controller:k13_en.png?nolink |}}+{{:en:controller:7_0.8.png?nolink |}}
  
 Currently, voltage settings for all throttles and brakes are common. \\ Currently, voltage settings for all throttles and brakes are common. \\
Line 408: Line 413:
 **Brake min** and **Brake max** — range of the analog brake lever, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. \\ **Brake min** and **Brake max** — range of the analog brake lever, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. \\
  
 +**Brake button power** — braking force when pressing the brake button relative to the phase braking level, in percent (%). This setting allows you to adjust the level of braking force with the brake levers with integrated brake buttons. \\
 **Invert brake** — inverts the voltage value from the built-in brake lever. Select **On** to enable. It is useful to enable when the voltage brake lever with reverse voltage is connected to the On-board computer and you want to use the value **Auto** in the menu item **Controller** > **Control** > **Control source**. The digital brake grip (i.e. button) connects to the On-board computer, see section **[[en:display:start#buttons_setup|Buttons setup]]**. \\ **Invert brake** — inverts the voltage value from the built-in brake lever. Select **On** to enable. It is useful to enable when the voltage brake lever with reverse voltage is connected to the On-board computer and you want to use the value **Auto** in the menu item **Controller** > **Control** > **Control source**. The digital brake grip (i.e. button) connects to the On-board computer, see section **[[en:display:start#buttons_setup|Buttons setup]]**. \\
 **Active braking** — enables brake to use the battery for stopping. Select of values **On** and **Off**. \\ **Active braking** — enables brake to use the battery for stopping. Select of values **On** and **Off**. \\
Line 435: Line 441:
 ===== Motor setup ===== ===== Motor setup =====
  
-The **Controller** > **Motor Setup** menu contains all settings related to electric motor operation parameters.+The **Controller**  > **Motor Setup**  menu contains all settings related to electric motor operation parameters.
  
 ==== Motor temperature sensor ==== ==== Motor temperature sensor ====
  
-In the menu section **Controller** > **Motor setup** > **Motor t°-sensor** you can select a temperature range in which a smooth power limit will occur (**Delta °t** parameter) and specify the maximum temperature (**°t max**).+In the menu section **Controller**  > **Motor setup**  > **Motor t°-sensor**  you can select a temperature range in which a smooth power limit will occur (**Delta °t**  parameter) and specify the maximum temperature (**°t max**).
  
-{{:en:controller:k15_en.png?nolink |}}+{{:en:controller:temp_0808.png?nolink|}}
  
-**°t max** — maximum electric motor temperature, in degrees Celsius (°C). Select of values from **50°C** to **200°C**, in increments of **1°C**. \\ +**°t max**  — maximum electric motor temperature, in degrees Celsius (°C). Select of values from **50°C**  to **200°C**, in increments of **1°C**. \\ **Delta °t**  — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning of the power limit, in degrees Celsius (°C). Select of values from **1°C**  to **100°C**, in increments of **1 °C**.
-**Delta °t**  — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning of the power limit, in degrees Celsius (°C). Select of values from **1°C** to **100°C**, in increments of **1 °C**. \\+
  
-It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors and select the one that displays data the most closely to room temperatureThe current measured temperature is displayed at **## Value °t  ##**. \\+In the menu item **Sensor type**  you can select the following types of temperature sensors that support the controller — **KTY81(82)**, **KTY83**, **KTY84**, **NTC10K (B:3950)**, **NTC10K (B:3380)**, **PT1000**To disable the temperature control, select the value **OFF**.
  
-In the menu item **Sensor type** you can select the following types of temperature sensors that support the controller — **KTY81(82)****KTY83**, **KTY84**, **NTC10K (B:3950)**, **NTC10K (B:3380)**, **PT1000**. To disconnect the temperature controlselect the value **OFF**.+It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors and select the one that displays data the most closely to room temperature. The current measured temperature is displayed at **# Value °t**
 + 
 +The **# °t resistance**  menu item displays the resistance of the motor temperature sensorwith an accuracy of /-10%.
  
 ==== Clutch ==== ==== Clutch ====
  
-In the menu section **Controller** > **Motor Setup** > **Clutch** you can configure a smooth engine launch for soft engagement clutch or freewheel. Useful for gear motors or mid-drives. At the moment, the setting works well only in the control mode **Torque**, because the clutch there is always engaged. An alternative option is to configure the acceleration limit in the modes **S1**, **S2**, **S3** in the menu section **Controller** > **Advanced modes**.+In the menu section **Controller**  > **Motor Setup**  > **Clutch**  you can configure a smooth engine launch for soft engagement clutch or freewheel. Useful for gear motors or mid-drives. At the moment, the setting works well only in the control mode **Torque**, because the clutch there is always engaged. An alternative option is to configure the acceleration limit in the modes **S1**, **S2**, **S3**  in the menu section **Controller**  > **Advanced modes**.
  
-{{:en:controller:k16_en.png?nolink |}}+{{:en:controller:k16_en.png?nolink&  }}
  
-The parameter **Mode** determines the way of operation:: \\ +The parameter **Mode**  determines the way of operation:: \\ **Accelerate**  — smoothly accelerates the motor until the load appears. \\ **Accelerate and hold**  — in addition to the previous one, it applies weak torque to the motor after the throttle is released, this mode allows you to switch speeds at mid-drive systems without using the pedals.
-**Accelerate** — smoothly accelerates the motor until the load appears. \\ +
-**Accelerate and hold** — in addition to the previous one, it applies weak torque to the motor after the throttle is released, this mode allows you to switch speeds at mid-drive systems without using the pedals. \\+
  
-**# Phase amps** \\  +**# Phase amps** \\ **Start time**  — maximum time for soft start, in seconds (s). Select values from **1s**  to **20s**, in increments of **1s**. \\ **Start current**  — phase motor current at which the load will be detected and the soft start is disabled, in amperes (А). Select values from **0.2А**  to **50.0А**, in increments of **0.2А**. This value must be higher than the phase current for specified acceleration of the motor without load. \\ **Detection time**  — the time during which the load must be present, after which the soft start will be switched off, in milliseconds (ms). Select values from **10 ms**  to **1000 ms**, in increments of **10 ms**. \\ **Acceleration**  — value in volts/seconds (V/s). Select values from **2V/s**  to **1000V/s**, in increments of **2 V/s**. The higher the value, the more you need to specify **Start current**, since the motor will consume more current during acceleration. \\ **Hold (20%)**  and **Hold (80%)**  — two parameters regulating the phase current supplied to the motor in the mode **Accelerate and hold**, in amperes (А). **20%**  — current at low speeds, **80%**  — current at about maximum speed. It is possible to determine the approximate values ​​by the no-load current of the motor. Select values from **0.2А**  to **50.0А**, in increments of **0.2А**. \\ **Hold enable time**  — time through which after the throttle has been pressed, torque hold will become available, in seconds (s). Select values from **1s**  to **120s**, in increments of **4s**.
-**Start time** — maximum time for soft start, in seconds (s). Select values from **1s** to **20s**, in increments of **1s**. \\ +
-**Start current** — phase motor current at which the load will be detected and the soft start is disabled, in amperes (А). Select values from **0.2А** to **50.0А**, in increments of **0.2А**. This value must be higher than the phase current for specified acceleration of the motor without load. \\ +
-**Detection time** — the time during which the load must be present, after which the soft start will be switched off, in milliseconds (ms). Select values from **10 ms** to **1000 ms**, in increments of **10 ms**. \\ +
-**Acceleration** —  value in volts/seconds (V/s). Select values from **2V/s** to **1000V/s**, in increments of **2 V/s**. The higher the value, the more you need to specify **Start current**, since the motor will consume more current during acceleration. \\ +
-**Hold (20%)** and **Hold (80%)** — two parameters regulating the phase current supplied to the motor in the mode **Accelerate and hold**, in amperes (А). **20%** — current at low speeds, **80%** — current at about maximum speed. It is possible to determine the approximate values ​​by the no-load current of the motor. Select values from **0.2А** to **50.0А**, in increments of **0.2А**. \\ +
-**Hold enable time** — time through which after the throttle has been pressed, torque hold will become available, in seconds (s). Select values from **1s** to **120s**, in increments of **4s**. \\+
  
-**Hold time** — the time during which torque will be applied after releasing the throttle, in seconds (s). Select values from **1s** to **120 s**, in increments of **1s**. \\+**Hold time**  — the time during which torque will be applied after releasing the throttle, in seconds (s). Select values from **1s**  to **120 s**, in increments of **1s**.
  
-<WRAP center round tip 60%>\\ Optimal settings for MAC motor: **Accelerate**, 15a, 50V/s, 200ms.</WRAP>+<WRAP center round tip 60%> \\ Optimal settings for MAC motor: **Accelerate**, 15a, 50V/s, 200ms.</WRAP>
  
-==== Manual setup the Hall sensors angles ====+===== Firmware update =====
  
-In general, it is not recommended to change these settings manually!\\ +In the menu section **Controller** > **Update and Settings**, you can update the Controller's firmware, reset settings, import or export a configuration. You can upload all controller settings to a microSD card. The created file with the name **NCconf.cfg** - **NCconf9.cfg** you can open with the "Notepad" program, see all your settings, make any changes, save. Likewise, you can import a previously saved configuration into the Controller. Trip computer settings cannot be exported or imported. On-board computer settings can be exported and imported in separate [[:en:display:start#import_and_export_of_settings|sections]] of the Onboard computer menu. This function is only available in the On-board computer firmware version **0.7B** and higher.
-In the menu section **Controller** > **Motor settings** **Manual angle setup** you can set up the Hall sensors angles of the electric motor\\+
  
-{{:en:controller:k17_en.png?nolink |}}+{{:en:controller:k3_en.png?nolink&  }}
  
-**Offset for square** — additional shift for square wave mode, in degrees (**°**)Select of values from **-30°** to **30°**, in increments of ****. \\ +**Import config.** — loads the settings from the file ** NCconf.cfg ** - ** NCconf9.cfg ** up to a maximum of 9 different configurations, choosing a file number from 1 to 9. After a successful import, error messages may appear in the message, this means that not all the settings have been imported. In this case, it is advisable to check the downloaded settings with the original file by opening it in Notepad.\\ 
-**Offset total fwd** — shift all Halls sensors by the specified value for the direct rotation of the motorin degrees (**°**)Select of values from **-60°** to **60°**in increments of ****. \\ +\\ 
-**Offset total bkwd** — shift all Halls sensors by the specified value for the reverse rotation of the motor., in degrees (**°**)Select of values from **-60°** to **60°**, in increments of ****. \\+**Export config.** - saves the settings to the ** NCconf.cfg ** ** NCconf9.cfg ** file up to a maximum of 9 different configurations, choosing a file number from 1 to 9.\\ 
 +\\ 
 +**Reboot** — restarts the device. If the settings have not been savedthey will be reset.\\ 
 +\\ 
 +**Reset Wh usage** — resets the accumulated number of Watt-Hours in the controllerThis indicator is displayed in the statistics of the On-board computer, see section **[[:en:display:start#statistics|Statistics]]** .\\ 
 +\\ 
 +**Reset stats** — resets mileage in kilometers.\\ 
 +\\ 
 +**Load defaults** — after a reset, the default settings are loaded but not saved. If you restart the Controller without saving after a reset, the previous settings will be loaded.\\ 
 +\\ 
 +**Erase data storage** — This function may be needed for the correct firmware update, rollback to default settings, in a situation where user actions lead to incorrect operation of the ControllerIf the controller has stopped saving the settingsdo a reset, wait 3 seconds, and try to save again.\\ 
 +\\ 
 +**Update firmware** — starting the firmware update processYou can download the current firmware version and read the rules of update in the **[[:en:firmware|Firmware]]**section. To update, download the firmware file to the root directory of the microSD card with the Fat/Fat32 file system. Insert the card with the contacts facing up into the slot on the On-Board Computer and select ** On **. When the update process is completea message appears on the screen **Update finished**. Press the left button and check the update version under **Controller** > **Device Information**. 
 +===== Control modes =====
  
-To shift all the halls, you must press the right button of the On-board computer, enter the shift angle, press the right button again. The value will be reset and the angle of all halls will change to the specified valueYou can change the angle of the hall shift in the opposite direction by setting a negative value. \\+In the menu section **Controller** > **Control modes** you can configure and save three presets of the parameters of the electric motor and switch between them using a 3-position switch or buttons on the On-board computer. The currently active mode number is displayed at the top of the main screenAfter setting, it is necessary to activate the modes in the menu item **Controller** > **Additional modes** > **Enable additional modes** by setting the value **On**. In the same menu **Controller** > **Additional modes** you can make detailed settings for each mode (see the section Additional modes).
  
-**Reset angles** — reset of all Hall sensors angles. Select of values **On** and **Off**. \\ +If there is no speed switch, then mode 1 is the defaultIf the switch is connected to the On-board computer, it is necessary to configure the On-board computer buttons in the **On-board computer** **Button settings** menu. See section **[[:en:display:start#buttons_setup|Buttons setup]]**.
-**Integration threshold** — analogue of Hall angles for sensorless engine control mode, in volts (**V**)\\ +
-**Hall adjust Ki** — the meaning of the coefficient is to find the midpoint of the position of the Hall sensors when adjusting them. Values from **0.02** to **5.00**, in increments of **0.02**. If the value of the coefficient is too small, then the tuning process will end before the midpoint is determined. If the value of the coefficient is too large, then the setting will not be completed and will stop by timeout, because the midpoint will not be found due to the angles changing too often.+
  
-==== Hall table ====+==== Modes setup ====
  
-The **Controller** > **Motor Setup** > **Hall table** menu section shows the Hall indices and Hall angles for the two directions of rotation of the electric motorThese indices are used for the internal operation of the Controller\\ +{{:en:controller:9_0.8.png?nolink&  }}
  
-{{:en:controller:k18_en.png?nolink |}} +The ** # Current mode ** line displays the currently selected control mode. List of possible options:\\ 
-~~CL~~ \\+**N** — neutral.\\ 
 +**S1** — speed 1.\\ 
 +**S2** — speed 2.\\ 
 +**S3** — speed 3.\\ 
 +**RV** — reverse.
  
-==== Motor parameters ====+Four parameters are used to configure each mode:\\ 
 +**Phase** — the maximum value of the phase current, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. When setting, consider the maximum phase current of your controller type. In most cases, we recommend specifying the value of the phase current 1.5-2 times higher than the battery current.
  
-Items in the **Controller** **Motor setup** menu section allow you to configure the parameters of the electric motor.+**Battery** — the maximum value of the battery current, in Amperes (**A**). Select of values from **2A** to **400A**, in increments of **2A**. When setting up, consider the capabilities of the connected battery and the maximum battery current of your controller type.
  
-{{:en:controller:k19_en.png?nolink |}}+**Power** — maximum power (discharge) of the battery, in kilowatts (**kW**). Select of values from **0.00kW** to **30.0kW**, in increments of **0.1kW**. Set to 0.0kW to disable the power limiting limit.
  
-**Pole pair** — the number of pole pairs of the stator winding of the electric motor determines the speed at which the motor shaft will rotate. This parameter is used to calculate RPM and speed. For a more accurate autodetection of the Hall sensors anglesyou must specify the correct value for the number of pole pairs for your motor. For the most popular motors, you can see this value in the table **[[en:motor_information|Motor Information]]**. If your motor is not listed in the table, check with the manufacturer for the number of pole pairs. \\+**Speed** — maximum speed in percentage (%). Select of values from **4%** to **150%**, in increments of **2%**. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[:en:controller:setup#speedometer_setup|Speedometer setup]]**)A speed value over 100% activates the field weakening modewhich allows the motor to accelerate above the supply voltage (see section **[[:en:controller:setup#field_weakening_setup|Field weakening setup]]**).
  
-**Spin direction** — this setting allows you to change the direction of rotation of the electric motor. Select of values **Forward** and **Invert**. Or you can swap two motor phases to change the direction of rotation.\\+==== Electric brake setup ====
  
-**Integration thr.** — analogue of Hall sensors angles for sensorless motor control mode, in volts (**V**). \\+**Braking phase** — the value of the phase current of braking by the motor, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. For braking to zero, it is recommended to enable **Active braking** in the section **Controller** > **Control**. When using limit switches on mechanical brakes, lower brake current change speed makes recuperation more smooth. 
 +==== Braking phase at speed control ====
  
-**Control mode now** — the current motor control modethe parameter switches the real-time control modebut does not save itSee below for description of each mode\\+**Braking ph. at speed** — phase braking current during speed control, in Amperes (A). Select of values from **0A** to **500A**in increments of **2A**This function allows you to slow down when you reset the throttle stick. Works only with Direct Drive motors, without clutch.
  
-**Control mode** — this parameter is loaded at start-up and can be savedAt the moment, the controller has the following motor control modes: \\+Also to use this mode should be selected: **Speed** or **Speed and Torque** mode in the **Controller** > **Control** > **Throttle Mode** menu itemIn the menu item **Controller** > **Control** > **Speed lim. at 0% throttle** enable the speed limit at 0% throttle (optional), enable if you need braking with completely released throttle. 
 +==== Regenerative braking setting ====
  
-  * **Sensorless** — motor control using BEMF integration, parameter **Integration threshold** is usedIt is rather insensitive to tuning, but more accurate tuning may be required for high-speed motors (such as RC). At the moment, the sensorless does not have a start-up algorithm, it works stably only at some speed. Hall setups start with sensorless mode.\\ +**Braking ph. at 0% throttle** — phase braking current with the throttle handle releasedin Amperes (A). Select of values from **0A** to **500A**in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released.
-  * **Square** — outdated control method used only for motor detection. \\ +
-  * **Combined** — start the motor on Hall sensorsthen switch to sensorless mode, the threshold is determined by the parameter radians per second (**rad/s**in the **From hall to s-less** menu item. Select of values from **0.00 rad/s** to **2.00 rad/s** in increments of **0.05 rad/s**. To convert values keep in mind that 1 rad/s to RPM = 9.5493 RPM. \\ +
-  * **FOC** — field-oriented control of the motor. \\ +
-  * **Hz** — 3-phase square with a fixed frequency. \\ +
-  * **Sine HZ** — 3-phase sine with a fixed frequency\\+
  
-**Interpolate halls** — smooth change of the Hall sensors angle based on speed. Used for FOC mode. Select of values **On** and **Off**. \\+This function will be active if additional modes are disabled in the **Controller** > **Advanced modes** menu section or if, with activated additional modes, in one of the menu sections **Mode S1**, **Mode S2** or **Mode S3** in menu item **Braking ph. at 0% throttle** was setup is **0A**. 
 +==== Reverse setup ====
  
-**Interpolation start** — the motor is always started from a discrete angle, if digital halls are used. After the specified speed, the angle starts to change smoothly. Select of values from **0 rad/s** to **100 rad/s**, in increments of **1 rad/s**. \\+**Speed reverse** — reverse speed, in percentage (%). Select of values from ** 2% ** to ** 150% **, in increments of ** 2% **. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[:en:controller:setup#speedometer_setup|Speedometer setup]]**). A speed value over 100% activates the field weakening mode, which allows the motor to accelerate above the supply voltage (see section **[[:en:controller:setup#field_weakening_setup|Field weakening setup]]**).
  
-**Frequency control** —  a separate mode that can be used to power equipment through a transformer or to dry the varnish on the motor windings. Select of values from **10 HZ** to **200 HZ**, in increments of **1 HZ**. \\+**Phase reverse** — the value of the reverse phase current, in Amperes (**A**). Select of values from **10A** to **500A**, in increments of **2A**. 
 +==== Field weakening setup ====
  
-**Boost square current** — in the sensorless or square mode, applies 100% PWM at the beginning of each winding switch. Starting from specified speed and minimum requested current. Select of values **On** and **Off**.+**Field weakening** — the magnitude of the field weakening current, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. This setting allows you to increase the maximum motor speed and depends on the supply voltage, in any case, the speed will be no more than the maximum supply voltage (**Vmax**) of the controller (**95V limit**).<WRAP center round info 60%> The current of weakening creates a field that acts against the field of the permanent magnets. The superposition of these fields creates an equivalent field that is below nominal. The attenuation efficiency depends on the parameters of the motor. The best results can be obtained with IPM motors. </WRAP>\\ 
 +<WRAP center round warning 60%>Warning! High Field weakening setting may damage your motor! It is not recommend to exceed 500Hz on a rotor for most 0.35mm steel motors</WRAP>
  
-**Boost current** — setting refers to the control mode **Square**the minimum current from which the rapid current pumping in the windings is turned on, in amperes (**А**). Select of values from **0A** to **100A**, in increments of **1A**. \\+To set up the weakeningyou need:
  
-**Boost speed** — setting refers to the control mode **Square**, the minimum speed after which the rapid pumping of current in the windings is turned on, in radians per second (**rad/s**). Select of values from **0.00rad/s** to **2.00rad/ms** in increments of **0.05rad/s**. \\+  for one of the control modes in the section **Controller**  > **Control modes**  specify a speed value greater than 100%for example, Speed 3 is 120%. 
 +  * set the weakening current value in the section **Controller**  > **Control modes**, you can start from 30A.
  
-**Max motor U** — limits voltage supplied to the motor, in volts (**V**)In most casesthis parameter is not needed. Select of values from **0V** to **100V**in increments of **1V**\\+Field weakening is activated when the maximum speed is reachedthe Controller adds weakening current, limiting the phase current and weakening current specified in the control modeThat is if the effective phase current is 70Aand the weakening current is set to 30Athen a minimum of 100A must be specified in the phase current settings. If the phase current increases to 80A, then only 20A will remain for weakening because 80A 20A = 100A.
  
-**kV** — motor parameterelectric revolutions per volt (**eRPM/V**).+Alsothe Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery). If the motor starts twitching on the suspended wheel, then it is necessary to reduce the weakening current.
  
-===== Battery =====+==== Current change speed ====
  
-In the **Controller** > **Battery** menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V** to **90V**, this is **21S** for Lithium-ion (Li-ion) batteries and **25S** for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[en:display:start#battery_capacity|settings]] of On-board Computer.+**# Current change speed**.
  
-{{:en:controller:k20_en.png?nolink |}}+  * acceleration, select of values from **50A/s**  to **50000A/s**, in increments of **100A/s**. 
 +  * braking, select of values from **50A/s**  to **50000A/s**, in increments of **100A/s**. 
 +  * shutdown, select of values from **50A/s**  to **50000A/s**, in increments of **100A/s**.
  
-**Full charge** — delta voltage relative to the maximum, at which when the controller is turned onwill reset the watt-hour consumption, in volts (**dV**)This setting resets the **From charge statistics** when the Controller is turned onSelect values from **0.00 dV** to **10.00 dV**, in increments of **0.3 dV**.  \\+Three parameters determine the rate of change of the current (smoothness). The higher the value, the faster the current build-up in the motor will occurFor conventional brake levers, it will be useful to reduce the parameter **braking**  for a smoother activation of the regenerationIf the throttle response seems too slow, you need to increase the parameter **acceleration**. The parameter **shutdown**  determines how quickly the current drops after throttle and brakes are released.
  
-**Supply max** and **Supply min** — battery voltage range, in volts (**V**). Select values from **20.00V** to **95.00V**, in increments of **00.1V**. Also, these settings are used for the **Converter** mode. \\+===== Advanced control modes =====
  
-For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**. \\  +In the menu section **Controller**  > **Advanced modes**  enables the control modes and activates the advanced settings for each of these modes.
-For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**. \\+
  
-<WRAP center round important 60%> +{{:en:controller:k5_en.png?nolink&  }}
-We guarantee stable operation of the Controller at voltages up to **90V** inclusiveUsing a battery over 90V may damage the Controller and void the warranty. +
-</WRAP>\\+
  
 +To activate the control modes, select **Controller**  > **Advanced modes**  > **Enable add. modes**  and to set **On**.
  
-**Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.  \\+In the menu **Controller**  > **Advanced modes**  > **Neutral by default**  you can activate the neutral mode (Nwhen the controller starts up, which will be active until one of the speed modes is activatedIn a neutral mode, only the electric brake operates, throttle and PAS are disabledThis mode is recommended for use with speed buttons (not a switch). The function does not work with a 3-position switch (functions of the S1of3 and S3of3 ports in the **Controller**  > **I/O configuration**  menu)
  
-**Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.  \\+~~CL~~
  
-**Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** to **30000 W**, in increments of **100W** \\+Each mode has its own section in the **Controller**  > **Advanced modes**  > **Mode S1Mode S2, Mode S3 **  with the following settings:
  
-**# DC voltage** — current supply voltage of the Controller, in volts (**V**).+{{:en:controller:5_0.8.png?nolink&  }}**Throttle mode**  — selection of the operating mode of the throttle leverread more in the section **[[:en:controller:setup#throttle_control_mode_setup|Throttle control mode setup]]**.
  
-===== Converter =====+**Acceleration lim.**  and **Deceleration lim.**  — are specified in ERPM/s, select of values from **0 ERPM/s**  to **500000 ERPM/s**, in increments of **200 ERPM/s **. These settings allow you to limit the speed of acceleration or deceleration of the motor, it is convenient to use on slippery surfaces. For setting go to the **Controller**  > **Status flags**  section, in this menu there are two parameters that register the maximum acceleration and deceleration — **Max acceleration**  and **Max deceleration**. **Reset**  the values of these parameters in the same section of the menu, then you need to ride your e-bike in order to register the current dynamics of acceleration and deceleration. You can use these values as a reference and decrease them if you need to limit change speed. If the type of surface changes, for example, it becomes too slippery, then these values can be reduced until it becomes comfortable to catch the moment when the wheel loses traction.
  
-In the menu section **Controller** **Converter**, can configure charging mode from the power supply through the motor. Charging through the inductor is not currently supported. For the power supply connection diagramsee this [[hhttps://drive.google.com/file/d/1KkEgWcJ5U-AEkk6GrXhDNlYXFCcsjpUQ/view|link]].+**Braking phase**  — the value of the phase current of braking by the motor, in Amperes (A). Select of values from **0A**  to **500A**, in increments of **2A**. For braking to zeroit is recommended to enable Active braking in the section **Controller**  > **Control**When using limit switches on mechanical brakes, lower brake current change speed makes recuperation more smooth.
  
-{{:en:controller:k21_en.png?nolink |}}+**Braking ph. at 0% throttle**  — phase braking current with the throttle handle released, in Amperes (A). Select of values from **0A**  to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. If **0A**  is specified or additional modes are disabled in the **Controller**  > **Advanced modes**  section of the menu, then for the recuperation level will be used value from menu item in the **Controller**  > **Control modes**  > **Braking ph. at 0% throttle**  menu item.
  
-**Enable** — turn on the converter mode and start charging. Select of values **On** and **Off**. \\+**Revers**  — reverse gear activation when the control mode is selected. Select of values **On**  or **Off**.
  
-**Auto-enable** — allows the automatic start of charging when the charging PSU is connected to the controller. Select of values **On** and **Off**. \\+**Cruise**  — activation of the cruise function. Select of values **On**  or **Off**. Convenient to use with cruise mode **Allow Throttle hold**  in the menu section **Controller**  > **Control**  > **Cruise**  > **Cruise**  to enable cruise in certain modes. See section **[[:en:controller:setup#cruise_control_setup|Cruise control setup]]**.
  
-**Detection threshold** — minimum voltage on phases when charger mode activates, also disables motor control, in volts per phase (**Vph**). Select of values from **10Vph** to **80Vph**, in increments of **1Vph**. \\+**Disable motor**  — completely disables motor control. Select of values **On**  or **Off**.
  
-**Battery max I** — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А** to **100.0A**, in increments of **0.5А**. \\+**Disable throttle**  — disable throttle control. Select of values **On**  or **Off**.
  
-**Battery min I** — minimum charge current when current is decreased by voltage, in amperes (**А**). Select of values from **0.5А** to **10.0A**, in increments of **0.5А**. \\+**Active braking**  — allow the brake to use the battery for stopping. Select of values **On**  or **Off**.
  
-**Undercharge** — voltage relative to maximum battery voltage setupin volts (**V**). Let's decrease the full charge voltage. Select of values from **0.00V** to **10.0V**, in increments of **0.1V**. \\+**Reverse on brake**  — after stoppingpressing the brake lever again activates reverse speed. Select of values **On**  or **Off**.
  
-**Current drop delta** — decreases charging current down to **Battery min I** as the battery reaches maximum voltage on specified voltage range, in volts (**dV**). Select of values from **0.0dV** to **20.0 dV** in increments of **0.5 dV**.+**Speed lim. at 0% throttle**  — allows limiting the speed when the throttle lever is released. Select of values **On**  or **Off**. Selecting **Off**  disables motor control when the throttle is released.
  
-**Supply max I** — maximum power supply current, in amperes (**А**). Select of values from **2.0 A** to **150.0 A**, in increments of **0.5 A**.+**Disable PAS**  — disables the Pedal Assist. Select of values **On**  or **Off**.
  
-**Supply drop U** — allowable voltage drop on wires or power supply, in volts (**V**). Select of values from **0.50 V** to **10.00 V**, in increments of **0.25 V**. \\+**PAS Scale**  — extra PAS multiplier for tuning, decreases PAS signal for smoother control on high power modes. Select of values from **1%**  to **100%**, in increments of **1%**.
  
-**Max motor t°** — setting the limitation of the heating temperature of the motor during charging, in degrees Celsius (**°C**). Select of values from **50°C** to **120°C**, in increments of **5°C**. \\+===== Control =====
  
-Below in the menu section, through the **#** sign, the real-time values of voltages and currents are shown: \\ +In the **Controller**  > **Control**  menu section you can setup setting the engine controls, throttle levers, torque and PAS sensors, cruise control.
-**# Battery I** \\ +
-**# Battery U** \\ +
-**# Supply I** \\ +
-**# Supply U** \\+
  
-After plugging in the power supply, the On-board Computer will display the battery charging process.+==== PAS and Torque sensor setup ====
  
-{{{:ru:controller:charging.png?nolink |}} **Indication to the right:**\\ +In the menu section **Controller**  > **Control**  > **Pedal Assist System**  you can set up the Pedal Assist System (PAS), which connects the electric motor when pedaling.
-**-22.1A** — information line parameter, depending on the On-Board Computer settings. \\ +
-**0:0:58** — time elapsed since charging started, hours, minutes, seconds. \\  +
-**I24.9** — charging current, in Amperes (**A**). \\ +
-**U53.7** — charging voltagein Volts (**V**)\\+
  
-**The indication in the middle** is the temperature of the motor and the controller, respectively, in degrees Celsius (**°C**).+ЧTo be able to connect the PAS system, it is necessary to order the PWM IO/PAS cable as an option. The PAS system connects to the Controller via the PWM IO/PAS wire to the **P1/P2**  ports of the **USB/PWM**  connector. When using a SEMPU pressure sensor, an additional signal output from the TH port of the connector **Control**  is required.
  
-**Indication to the left:** \\ +You can look at the connecting methods of various PAS systems at **[[:en:controller:setup#connection_diagram|Connection diagram]]**.
-**59.0V** — information line parameter, depending on the On-Board Computer settings. \\ +
-**15Wh** — the battery capacity in Watt hours (**Wh**). \\ +
-**100%** — the battery level, in percent (**%**). \\ +
-**I24.9** — the battery current, in Amperes (**A**). \\ +
-**U53.7** — the battery voltage, in Volts (**V**)\\+
  
 +The PAS, unlike the Torque sensor, controls the throttle by frequency and not by the force of rotation. The PAS setup menu consists of the following items:
  
-~~CL~~ \\+{{:en:controller:k7_en.png?nolink&  }}**PAS**  — selection of pedaling assistant type **PAS sensor**  or **Torque sensor**. If there is no PAS system, select **Disabled**.
  
-===== I/O port configuration =====+**PAS connection**  — 1-wire or 2-wire connection option, two wires are used for the angle sensor (encoder). \\ **Invert PAS**  — change of direction in case of 2-wire connection. Select of values **On**  or **Off**. \\ **PAS poles**  — number of impulses per pedal revolution. Select of values from **1**  to **200**, in increments of **1**. \\ **PAS min. freq.**  — the minimum pedal speed (cadence) at which the motor starts, RPM. Select of values from **1 RPM**  to **500 RPM**, in increments of **1 RPM**. \\ **PAS max freq.**  — the maximum pedal speed (cadence) at which the motor starts, RPM. Select of values from **10 RPM**  to **1000 RPM**, in increments of **5 RPM**.
  
-In the **Controller** **I/O configuration** menu section, you can configure the ports functionsThe controller has eight digital ports that can be configured for different functions — **S1****S3**, **RV****CR**, **P1****P2**, **P****M**. See section **[[en:controller:setup#connection_diagram|Connection diagram]]**. \\+**# PAS freq.**  — the value of the signal coming from the PAS in real-time. \\ **PAS timeout**  — the time after which the motor turns off after stopping pedaling, in seconds (s)Select of values from **0.02s**  to **5.00s**, in increments of **0.02s**. \\ **PAS filter**  — smoothing the control signal for smoother operationin hertz (Hz). Select of values from **1 Hz**  to **100 Hz**, in increments of **1 Hz**. \\ **PAS min out**  — minimum control level when PAS is running, in percent (%)Select value from **0%**  to **100%**, in increments of **1%**. \\ **PAS max out**  — maximum control level, in percent (%). Select of values from **0%**  to **100%**, in increments of **1%**. By analogy with the “pressed” throttle, PAS sends a signal within the specified limits.
  
-Sixteen CAN ports are additionally available **CAN port 1** - **CAN port 16**, the signal source for which can be configured on the On-board computer or uLight. These are software values, there are fewer physical inputs on the boards, at the moment there are eight CAN ports **IO1** - **IO8** available in the On-board computer plus four Hotkeys (buttons on the On-board computer). In the future, six CAN ports ** I1 ** - ** I6 ** will be added to the uLight board. \\+Further in the menu are the settings related to the pressure sensor (Torque sensor).
  
-{{:en:controller:k23_en.png?nolink |}}+**Pressure scale**  — in Newton-meters/volts (Nm/V). You can calibrate by placing a load on the pedal and calculate the torque on the shaft through the lever. Select value from **0.0 Nm/V**  to **100.0 Nm/V**, in increments of **0.5 Nm/V**. \\ **Zero pressure**  — zero pressure, in millivolts (mV). Select of values from **0mV**  to **10000mV**, in increments of **10mV**. \\ **Protection pressure**  — switching off the pressure sensor when the threshold of the specified value is exceeded, in millivolts (mV). Select of values from **0mV**  to **10000mV**, in increments of **100mV**. \\ **Torque averaging**  — period for which is torque value updated. Measured in half turns (turn/2). If the torque sensor measures only one pedal, then the period must be a multiple of two. Select of values from **1 turn/2**  to **20 turn/2**, in increments of **1 turn/2**.
  
-In the section **Controller** > **I/O configuration** > **Port state**, you can check input activation when contact shorted to GND. When a signal is applied, the value will change from **0** to **1**. Below in the menu items **# Throttle** and **# Brake** you can see the voltage on the throttle and brake leversrespectively. +**# Torque**  — shows the current torque at the sensorin Newton-meters (Nm).
-~~CL~~ \\+
  
-In the item ** Controller ****I/O configuration** **Speeds mode** you can select the method for switching additional modes **S1**, **S2****S3** for inputs in the Controller or CAN inputs - **Switch** or **Buttons**. \\+**# Human watt**  — shows the average power you develop when pedaling, in watts (W). \\ **Human watt min**  — the minimum power you develop to activate the motor, in watts (W). Select of values from **0 W**  to **500 W**, in increments of **10 W**. \\ **Human watt max**  — the maximum power for 100% activation, in watts (W). Select of values from **0 W**  to **1000 W**, in increments of **10 W**.
  
-{{:en:controller:k24_en.png?nolink |}}+**Torque min**  — the torque at which the throttle signal starts to increase, Newton-meters (Nm). Select of values from **0 Nm**  to **100 Nm**, in increments of **2 Nm**. All values less than this level is 0% of throttle. \\ **Torque max**  — the torque, which limits the level of 100% throttle, Newton-meters (Nm). Select of values from **0 Nm**  to **300 Nm**, in increments of **2 Nm**. \\ **Instant Torque**  — allows torque sensor activation without rotation. Select of values **On**  or **Off**. The pressure sensor also includes frequency configuration and output level configuration as well as the usual PAS.
  
-Available functions for the Controller ports **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M** and CAN ports **CAN port 1** - **CAN port 16**: \\ +==== Remote control ====
-**OFF** — disable port. \\ +
-**RV** — reverse. \\ +
-**CRe** — enable cruise. \\ +
-**CR+** — increment cruise speed (when cruise is active). \\ +
-**CR-** —  decrement cruise speed (when cruise is active). \\ +
-**CRr** — restore last saved cruise speed with button, activated only above min cruise speed. \\ +
-**BK** — brake button. \\ +
-**DM** — disable motor (disable throttle, brake and PAS). \\ +
-**DTH** — disable throttle. \\ +
-**DPAS** — disable PAS. \\ +
-**SWSNS** — input for Gearsensor to reduce motor torque (WIP). In development. \\ +
-**N** — activates the neutral mode forcibly, resets speed mode counter if used. If neutral is activated by default, you need to change speed mode again to exit neutral. \\ +
-**nBK** — inverted brake button input, activates the brake when the contact is opened. \\ +
-**S1** — speed 1. \\ +
-**S2** — speed 2. \\ +
-**S3** — speed 3. \\ +
-**S1of3** — speed 1 for 3-position switch. \\ +
-**S3of3** — speed 3 for 3-position switch. \\ +
-**Scyc** — cycle speed mode, sequential switching with one button. \\ +
-**S++** — increment speed, switching the speed from low to high with one button. \\ +
-**S--** — decrement speedи, switching the speed from high to low with one button. \\ +
-**SPSNS** — input for external speed sensor. \\ +
-**Spec.** — special port function (like PWM or PAS). \\+
  
-Further in the menu, there are items for configuring the PWM outputs +The **Controller**  > **Control**  > **RC Control**  menu section allows you to configure the remote control of the Controller using an external RC receiver.
-~~CL~~ \\ +
-==== PWM output setup  ====+
  
-To activate the **PWM P1** or **PWM P2** output, the **Controller** > **Port Setup** menu should be set to **Spec.** mode and **PAS** disabled. \\+{{:en:controller:k8_en.png?nolink&  }}
  
-**PWM freq** — selection of frequency of additional PWM output on ports **P1/P2**. Select of values PWM frequency — **100Hz**, **500Hz**, **1kHz**, **5kHz**, **10kHz**, **24kHz (FAN)**. For a conventional light bulblarge values are not needed. Select the frequency **100Hz**, this will be enough to avoid flickering. The high frequency marked ** FAN ** is used to control the fan, this is their standard frequency\\+Input for radio control via PWM (PWM), connects to the **P1**  port of the **USB/PWM**  connector on the Controller boardTo activate the functionselect the **PWM**  value in the **P1 Input Mode**  menu item.
  
-**PWM P1** and **PWM Р2** — selection of operating modes: \\ +The **# Input Freq.**  and **# Width**  menu items show the current signal value in hertz (**Hz**) and milliseconds (**ms**), respectively.
-  * **Disabled** — mode not selected\\ +
-  * **Stop-light** — activated when the brake is pressed. \\ +
-  * **Headlight** — activated when the controller is enabled. \\ +
-  * **t°C motor** — activated beyond the two deltas of the motor temperature, as the motor heats up will increase the PWM duty Delta °t set up on menu **Controller** **Motor setup** > **Motor t°-sensor**). \\ +
-  * **t°C controller** — activated from 40°Сmaximum value at 80°С temperature of the Controller\\+
  
-**PWM Pn Min** **Max** — indicates the output range of the PWM (duty)select of values from **0%** to **100%**, in increments **1%**. \\ +In the menu item **Function**  selects the control function — **Off**, **Throttle**, **Brake**  or **Throttle and brk**.
-**PWM Pn t° Min** / **t° Max** — selection of motor or controller temperature,  select of values from **0°С** to **100°С**, in increments **1°С**.+
  
-===== Extra parameters =====+~~CL~~
  
-In the menu section **Controller** > **Extra parameters** you can set up various additional settings of the Controller.+ \\ Adjust the throttle and/or brake range as indicated by the signal.
  
-==== The power button and auto shutdown ====+**# Throttle range** \\ **Throttle min**  — minimum throttle value, in milliseconds (ms). Select of values from **0.00 ms**  to **10.00 ms**, in increments of **0.01 ms**. \\ **Throttle max**  — maximum throttle value, in milliseconds (ms). Select of values from **0.00 ms**  to **10.00 ms**, in increments of **0.01 ms**.
  
-The controller power button is located on the back of the On-Board ComputerIn the **Controller** **Extra parameters** **Disable button** menu itemyou can select the way to turn on/off the Controller, which turns on when it is powers-up or the button contacts are closedIn the off mode, the controller consumes about 100 μA, so if you reconnect the power supply without discharging the capacitorsthe controller may not start\\+**# Brake range** \\ **Brake min**  — minimum brake value, in milliseconds (ms). Select of values from **0.00 ms**  to **10.00 ms**, in increments of **0.01 ms**. \\ **Brake max**  — maximum brake valuein milliseconds (ms). Select of values from **0.00 ms**  to **10.00 ms**in increments of **0.01 ms**.
  
-{{:en:controller:k25_en.png?nolink |}}+==== Cruise control setup ====
  
-Selecting modes for **Disable button**: \\ +In the menu section **Controller**  > **Control**  > **Cruise**  you can set up the cruise control functionAfter connecting buttons or switches for cruise control to the ports of the Controller or Onboard Computeryou need to configure the functions that relate to cruise control:
-**None** — the controller turns on when it is power-up up or when the power button is closed, does not turn off. \\ +
-**Switch** — the controller turns on when the power button is closed (when EN shorted to GND), turns off when it opens\\ +
-**Button** — the controller turns on the button on the On-Board Computer, press it for 2 seconds, and release, to disable it, press and hold the button again. \\ +
-**CAN** — the controller turns on when it is powers-up or the button contacts shortsdisables only when another device on CAN bus will send a request to disable. This function is used when there are several controllers on a system, where one of them is set to button or switch mode, and the other in CAN mode. \\+
  
-**Auto shutdown** — activation of the controller shutdown function after a while if the motor does not spinSelect of values **On** and **Offл**. The shutdown time is set in item **Sleep time**. \\+**CRe**  — cruise activation. \\ **CR **  — increase cruise speed (when active). \\ **CR-**  — decrease cruise speed (when active)\\ **CRr**  — restoring cruise (turning on the last saved speed).
  
-**Sleep time** — selection of the controller shutdown time when the **Auto shutdown** function is activatedin seconds, (**s**). Select of values from **30s** to **1500s**, in increments of **5s**. \\+For more information about configuring these functions, read the **[[:en:controller:setup#i_o_port_configuration|I/O port configuration]]**section below. If the cruise control button is connected to the On-board computerthen you need to configure it in the **[[:en:display:start#buttons_setup|Buttons setup]]**section.
  
-**Lock at turn-on** — the function locks controller inputs when enabled until the password is entered on the On-Board Computerif there is no On-Board Computerenabling this setting will permanently lock the controller.+{{:en:controller:k9_en.png?nolink&  }}In the **Cruise**  menu item, you can select several control modes: \\ **Disabled**  — cruise control disabled. \\ **Button**  — activation of cruise control at the push of a button. The response time of the button is determined by the parameter **Cruise EN time**. \\ **Switch**  — activation of cruise control by turning on the switch, time is not used. \\ **Throttle hold**  — activation of cruise control by holding the throttle for a certain time in one position. The response time is determined by the parameter **Cruise EN time**. The accuracy is set by the parameter **Cruise by throttle**  in percent (%). Select of values from **1%**  to **30%**in increment of **1%**. Accuracy is essentialas the throttle lever moves slightly during the ride due to shaking. The default is **2%**. \\ **Allow Throttle hold**  — similar to the previous mode, with the difference that to activate the cruise control, you must additionally press the cruise button.
  
-==== Speedometer setup ====+Next are the menu items for setting the cruise:
  
-The next block of settings in the menu section **Controller** > **Extra parameters** refers to the speed calculation settingIf you use an external speed sensor connected to the On-board computeryou need to configure it in menu **[[en:display:start#data_sources_setup|Data source setup]]**.+**Cruise restore**  — this function activates the last saved cruise speed. To enableselect the **CRr**  function when configuring **[[:en:controller:setup#i_o_port_configuration|I/O ports]]**. The function can be deactivated by selecting the parameter **Disabled**.
  
-{{:en:controller:k26_en.png?nolink |}}+**Cruise EN time**  — setting the cruise activation delay in seconds after enabled button (**s**). Select of values from **0.25s**  to **30.00s**, in increments **0.25s**.
  
-**Speed calculation** — enabling speed calculation in the Controller. Useful for multi-motor configurations, you can turn off the speed calculation on some motors. Select of values **On** and **Off**. \\+**Cruise level**  — selects what speed cruise will use:
  
-**Circumference** — wheel circumference, in millimeters (mm). Select of values from **0mm** to **3000mm**, in increments of **5mm**. To calculate the circumference, you can use [[https://www.omnicalculator.com/math/circumference|online calculator]]. \\+  * **Throttle**  — speed depends on the position of the throttle leverturns on instantly. 
 +  * **Speed**  — cruise enables when **Safe acceleration**  reached after that uses current speed as a reference. 
 +  * **Mixed**  — if controller cant use speed reference, uses throttle value. 
 +**Cruise smoothness**  — this setting limits acceleration during cruising so that there are no jerks, measured in electrical revolutions per minute per second (ERPM/s). To get the value in rpm, the ERPM/s value must be divided by the number of pole pairs of the electric motor. Select of values from **0 ERPM/s**  to **50000 ERPM/s**, in increments of **50 ERPM/s**.
  
-**Motor sprocket** — this setting specifies the number of sprocket teeth on the motor (notional), which allows you to set the gear ratio from motor shaft to the wheel. Alsothis setting can be used as a reduction ratio for gear motors\\+**# Used for cruise activation**: \\ **Safe acceleration**  — limits the acceleration at which the cruise is activate, for example, to prevent it from engaging when accelerating, in electrical revolutions per minute per second (ERPM/s). Select value from **100 ERPM/s**  to **10000 ERPM/s**in increments of **100 ERPM/s**. \\ **Min. speed**  — speed below which you can not activate cruise or recovery, in kilometers per hour (km/h). Select of values from **3 km/h**  to **127 km/h**in increments of **1 km/h**.
  
-**Wheel sprocket** — the number of teeth of the wheel sprocket, similar to the setting **Motor sprocket**. \\+Additionally, to control the cruise, you can use the **CR **  and **CR-**  functions for the buttons, which adjust the cruise speed when it is active.
  
-If you have a wheel motor, then in the section **Controller** > **Motor setup** you need to specify the number of **Pole pair** (divide the number of magnets by two). For gear motors or mid-drives, it is recommended to install an external speed sensor that connects to the Onboard computer or to any of the controller ports.+What actions disable cruise control:
  
-==== Master-controller ====+  * pressing the brake, analog or digital. 
 +  * repeated throttle press. 
 +  * if a switch is used — when it's disabled. 
 +  * reverse enable.
  
-{{:en:controller:k27_en.png?nolink |}} +==== Throttle and brake curves setup ====
-In the menu section **Controller** > **Extra parameters** > **Master-controller** you can enable the function of controlling other controllers from the current one. This setting is suitable for multi-motor configurations where control (throttle, brake and etc.) is connected into one of the controllers directly. +
-~~CL~~ \\+
  
-==== Other settings ====+In the menu section **Controller**  > **Control**  > **Throttle/brake curves**  you can set up the behavior of the throttle and brake levers. In **Throttle preset**  and **Brake preset**  menu items you can select one of the typical settings, select one of the throttle or brake presets, and press enter, the preset will be loaded.
  
-{{:en:controller:k27_en.png?nolink |}} +{{:en:controller:k10_en.png?nolink&  }}
-**Limit t° CPU** — limiting the temperature of the processor, in degrees Celsius (**°C**). When the specified threshold is reached, the phase current will be limited. Select of values from **60°C** to **105°C**, in increments of **5°C**. \\+
  
-** Device ID** — setting the device number in the CAN networkThis number is displayed in the menu section **Settings** **Devices** in front of each device that is connected to the network using the [[en:levcan|LEVCAN protocol]] +You can select the following types of throttle and brake presets: \\ **Linear**  — smooth increase, direct dependence\\ **Exponential**  — slow increase. \\ **Normal**  — average between linear and exponential. \\ **Polynomial**  — average between normal and exponential.
-~~CL~~ \\+
  
-===== PID regulators =====+Manual setting of throttle and brake position points is also available, to do this select **None**  in **Throttle preset**  or **Brake preset**  and enter the value manually. There are eight position points available for throttle and brake:: \\ **Start**  — starting point, in percentages (%). Select of values from **0%**  to **100%**, in increments of **1%**. \\ **1**-**6**  — midpoints, in percentages (%). Select of values from **0%**  to **100%**, in increments of **1%**. \\ **End**  — end point, in percentages (%). Select of values from **0%**  to **100%**, in increments of **1%**.
  
-In the **Controller** > **PID regulators** menu section, various signals of proportional-integral-derivative (PID) regulators are configured - devices in the control loop with feedback used in automatic control systems to generate a control signal in order to obtain the required accuracy and the quality of the transition process. **Settings for advanced users**\\ +You can also manually edit the value of each point in the loaded preset.
  
-{{:en:controller:k28_en.png?nolink |}} +~~CL~~
-Two or three coefficients are used for the settings of each regulator: \\ +
-**Ki** — integral coefficient. \\  +
-**Кp** — proportional coefficient. \\ +
-**Kd** — differentiating coefficient. \\+
  
-**Square Ki, Kp** — phase current regulator for a square wave. \\ +==== Control source ====
-**FOC Ki, Kp** — phase current regulator for FOC mode. \\ +
-**FW Ki, Kp** — field weakening coefficients. \\ +
-**DCv Ki, Kp** — voltage regulator on the DC bus. \\ +
-**DCi Ki, Kp** — current regulator on the DC bus. \\ +
-**DCw Ki, Kp** — power calculator. \\ +
-**Speed Ki, Kp, Kd** — speed regulator for throttle control modes **Speed** and **Speed+torque**. \\ +
-**PLL Ki, Kp** — speed regulator for motor angle interpolation. \\ +
-**Acceleration Kp, Ki** — deceleration and acceleration regulator. +
-~~CL~~ \\ +
-===== Status flags =====+
  
-The **Controller** > **Status Flags** menu section displays errors that may occur during the operation of the Controller. If an error occurs, the parameter value changes to **On**.\\+The controller supports the connection of controls (throttle, brake, switches, and buttons) to the Controller, On-board computer, ulight board, or mixed connection when one part of the periphery is connected to the Controller, and the second part to the On-board computer, or to ulight and On-board computer. This is necessary in the case of Tork/PAS sensor configurations in the Controller throttle lever in the On-board computer. In the menu item **Controller**  > **Control**  > **Control Source**  you can set up the control source of the Controller`s.
  
-{{:en:controller:k29_en.png?nolink |}}+{{:en:controller:k11_en.png?nolink&  }}
  
-**Reset?** — reset all statuses. Values **On** and **Off**. \\ +Select of control options: \\ **Auto**  — all sources will control the СontrollerBuilt-in and externalconnected via CAN bus (for example, On-board computer or ulight). \\ **Embedd**  — only what is connected directly to the Сontroller. \\ **Remote**  — control only via CAN bus (via On-board computer or Microlight). \\ **Disabled**  — disables any control of the Controller.
-**Max acceleration** — maximum acceleration, in ERPM/s. \\ +
-**Min deceleration** — maximum deceleration, in ERPM/s. \\ +
-**Overload current** — the last recorded current on the phases, in Amperes\\ +
-**Overload** — exceeding the permissible current values. Values **On** and **Off**. \\ +
-**Over-Field weakening** — weakening error. Values **On** and **Off**. \\ +
-**Supply overvoltage** — too high supply voltage, the error will appear above 95V, but in general depends on the controller model. Values **On** and **Off**. \\ +
-**Supply undervoltage** — too low supply voltageless than the minimum battery supply threshold. Values **On** and **Off**. \\ +
-**12V protection** — breaking down or error on the 12V power line. Values **On** and **Off**. \\ +
-**Brake error** — brake lever connection error. Values **On** and **Off**. \\ +
-**Throttle error** — throttle lever connection error. Values **On** and **Off**. \\ +
-**Hall error** — Hall sensor connection error. Values **On** and **Off**. \\ +
-**Code error** — error executing firmware code. Values **On** and **Off**. Let us know if this error occurs. \\ +
-**PAS protection** — PAS error. Values **On** and **Off**. \\ +
-**Controller overheat** — overheat protection of the controller. Values **On** and **Off**. \\ +
-**Motor overheat** — overheating protection of the electric motor. Values **On** and **Off**. \\ +
-**Protection fail** — hardware errormalfunction of all protection systems during controller self-test. If this error occurs, the operation of the Controller will be impossible. Values **On** and **Off**. \\ +
-**Voltage on phases** — overvoltage on phases. Values **On** and **Off**. \\ +
-**CAN: error** — CAN-bus errors. Values **On** and **Off**. Let us know if this error occurs. \\ +
-**LEC** — types of errors on the CAN bus. If everything is alright you will see the value **Ok**. In case of errors, there will be values -  **Stuff**, **Form**, **Acknowledgment**, **Bit recessive**, **Bit dominant**, **CRC**, **SW**. Tell us the code if this error occurs. \\ +
-**Receive w/error** — CAN-bus errors on receiving. \\ +
-**Sent w/error** — CAN-bus errors on transmitting. \\ +
-**CAN state** — overloading buffers. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **OVR0**, **OVR1**, **OVR01**. Tell us the code if this error occurs. \\ +
-**CPU Load** — current load of the central processor, in percentage (**%**).+
  
-===== Debug information =====+~~CL~~
  
-The menu section **Controller** > **Debug information** shows the main parameters of your Controller, electric motor, and the whole system - temperature, rpm, voltage, and current, as well as the values of the current regulators. \\+==== Throttle control mode setup ====
  
-{{:en:controller:k30_en.png?nolink |}} +The menu item **Controller**  > **Control**  > **Throttle mode**  you can set up throttle lever mode.
  
-**Temp FET** — temperature of the field-effect transistors (MOSFETs) of the Controller, in degrees Celsius (**°C**). \\ +{{:en:controller:6_0.8.png?nolink&  }}
-**Temp Motor** — temperature of the electric motor, in degrees Celsius (**°C**). \\ +
-**DC current** — DC current, in amperes (**А**). \\ +
-**DC voltage** — DC voltage, in volts (**V**). \\ +
-**AC current** — AC current, in amperes (**А**). \\ +
-**AC voltage** — AC voltage, in volts (**V**). \\ +
-**Motor U0** — DC voltage on phases, in volts (**V**). \\ +
-**System 12V** — voltage on the CAN bus 12V, in volts (**V**). \\ +
-**System 5V** — voltage on the CAN bus 5V, in volts (**V**). \\ +
-**RPM** — motor speed, in RPM (**RPM**). \\ +
-**ERPM** — electric revolutions of the motor per minute (**ERPM**). \\ +
-**Hall input** — this parameter allows you to check the functionality of the Hall sensors. There are three digits in this item, each shows the signal level, if you rotate the motor slowly by hand, all three digits should change. If none of the digits change, check if the Hall connector is connected or the ground may be broken. If one of the digits does not change - there is no contact or the sensor wire is broken. To check the contacts in the controller, disconnect the Hall connector and measure the voltages on the controller connector. There should be about 4V on the signal lines of the Halls, 5V on the power supply, and about 3V on the temperature sensor line. \\ +
-**Hall index** — virtual position of the motor, digits from 1 to 6 (normal operation). \\ +
-**Throttle %** — the percentage of how much the throttle is pressed. \\ +
-**Brake %** — the percentage of how much the brake is pressed. \\ +
-**Speed request** — set point for the speed regulator, in eRPM. \\ +
-**Torque request** — phase current request, either positive throttle or a negative brake. \\ +
-**Torque limit** — current limit for this type of controller, taking into account overheating\\ +
-**Temp CPU** — CPU temperature, in degrees Celsius (**°C**).+
  
-Next in the menu are the sections **Debug FOC** and **Remote inputs**, which are described below. +Three throttle modes options are available: \\ **Speed**  — a similar mode is used in Infineon controllers and non-programmable low-cost controllers and is characterized by the use of maximum current to reach a given speed. In this mode, the maximum thrust is used until the desired speed is reached, the thrust is not regulated by the throttle grip. \\ **Torque**  — in this mode, the throttle controls phase current, the thrust is limited by the angle of rotation of the throttle. \\ **Speed torque**  — combined mode (as Kelly)similar to the operation of the gas pedal in a car with an internal combustion engine.
-  +
-==== Debug FOC ====+
  
-In the menu section **Controller** > **Debug information** > **Debug FOC** \\+In the case of selecting the **Speed torque**  mode, pressing throttle to 50%, when achieved 50% speed, the current consumption will be reduced to hold speed. The acceleration current will also be proportionally lower.
  
-{{:en:controller:k31_en.png?nolink |}}+==== Throttle and brake voltage range setup ====
  
-**U Q** — Q-axis voltage, in volts (**V**). \\ +The menu items in the **Controller**  > **Control**  section allow you to set the voltage ranges of the throttle and brake grips.
-**U D** — D-axis voltage, in volts (**V**). \\ +
-**I Q** — Q-axis current, in amperes (**А**). \\ +
-**I D** — D-axis current, in amperes (**А**). \\ +
-**Ireqest Q** — Q-axis current request, in amperes (**А**). \\ +
-**Ireqest D** — D-axis current request, in amperes (**А**) +
-~~CL~~ \\ +
-==== Remote inputs ====+
  
-In the menu section **Controller** > **Debug information** > **Remote inputs** you can view the parameters of the throttle and brake levers connected to other devices connected to the CAN-bus (On-board computer or uLight)\\+{{:en:controller:7_0.8.png?nolink&  }}
  
-{{:en:controller:k32_en.png?nolink |}} +Currently, voltage settings for all throttles and brakes are common\\ **Throttle**  — shows the voltage of throttle grip connected to the controller, in volts (V). \\ **Throttle min**  and **Throttle max**  — range of the throttle grip, in millivolts (mV). Select of values from **0 mV**  to **15 000 mV**, in increments of **10 mV**. If the maximum value is exceeded by 5%, protection against broken throttle grip will be activated. If the range is incorrectly set, then when you fully press the throttle grip, the electric motor will turn off, in this case, you need to increase the range value.
-**Throttle** — voltage on the throttle lever at a remote source (On-board computer or uLight), in volts (**V**). \\ +
-**Brake** — voltage at the brake lever at a remote source (On-board computer or uLight), in volts (**V**). \\ +
-**Throttle % **— the percentage of how much the throttle pressed at a remote source. \\ +
-**Brake %** — the percentage of how much the brake pressed at remote source. +
-~~CL~~ \\ +
-===== Logger =====+
  
-In the **Controller ** **Logger** menu section, you can enable and configure the data logging during the operation of the Controller. This functionality is experimentalerrors may occur. The file is saved in ** CSV ** format to an SD card inserted into the On-board computer. To view the fileyou can use the service [[https://datazap.me/|Datazap]]. The SD card must have a FAT32 file system.+**# Brake**  — shows the voltage of the brake connected to the controller, in volts (V). \\ **Brake min**  and **Brake max**  — range of the analog brake lever, in millivolts (mV). Select of values from **0 mV**  to **15 000 mV**in increments of **10 mV**.
  
-{{:en:controller:k33_en.png?nolink |}}+**Brake button power**  — braking force when pressing the brake button relative to the phase braking level, in percent (%). This setting allows you to adjust the level of braking force with the brake levers with integrated brake buttons. \\ **Invert brake**  — inverts the voltage value from the built-in brake lever. Select **On**  to enable. It is useful to enable when the voltage brake lever with reverse voltage is connected to the On-board computer and you want to use the value **Auto**  in the menu item **Controller**  > **Control**  > **Control source**. The digital brake grip (i.e. button) connects to the On-board computer, see section **[[:en:display:start#buttons_setup|Buttons setup]]**. \\ **Active braking**  — enables brake to use the battery for stopping. Select of values **On**  and **Off**. \\ **Brake at overheat**  — enables full torque braking when motor overheated. Select of values **On**  and **Off**. \\ **Reverse on brake**  — after stopping, pressing the brake lever again activates reverse. Select of values **On**  and **Off**.
  
-**Start logging** — to start recording, select **On** and press the right button of the On-board computer. After that, the **#State** menu item will change to **Waiting** status. The recording will start automatically after pressing the throttle grip. If an error occurs during the recording process, you will see its code in the ** # Error code ** menu item. In case of an error, firstly, check that the SD card has the FAT32 file system, and secondly, that there is free space on the SD card for recording. Additionally, you can delete unnecessary files from the card. After that, restart the Controller and start recording again. If the error repeats, contact us through the website or chat technical support and report the error code.+==== Setup 100% speed value ====
  
-**Stop logging** — stop recording, select **On** to end recording. +The menu items in the **Controller**  > **Control**  section allow you to adjust the 100% speed levelThe maximum speed in the field weakening mode is 150%.
-~~CL~~ \\ +
-**Start mode** — selection of recording start mode:  +
-  * **Manual** — enable manual recording. +
-  * **At start** — recording starts automatically when the Controller is turned on.+
  
-**Log time** — two parameters of time for recording to choose from: +{{:en:controller:k14_en.png?nolink&  }}
-  * **Time step** — delta of time since the previous record. +
-  * **Sys time** — global time, which is incremented after the start of the controller.+
  
-**Log rate** — delay between records of values. You can choose either the number of PWM cycles (**PWM1**, **PWM2**, **PWM5**, **PWM10**), either time (**1ms****10ms**, **20ms****100ms****1s****5s****10s****30s**).+**Speed ref. filter**  — filter mode selection. Select of values **OFF**, **Linear**, **Quadratic**, **Cubic**. For the control modes **Speed**  and **Speed torque**, a speed reference filter is appliedfor a smoother response to the throttle change. The filter algorithm calculates the difference between the previous speed request and the current onemultiplies the error by a power of 1,2,3 (linearquadratic, and cubic, respectively), and multiplies by a factor. The resulting value is used as the cutoff frequency of the low-pass filter. The larger the change, the sharper the response to it.
  
-**Mode** — recording mode selection: +**Filter factor**  — sets the filtration factor. Select of values from **0**  to **30000**, in increments of **100**.
-  * **Buffered** — buffering and recording in segments.  +
-  * **Max rate** — continuous recording mode.+
  
-**Data averaging** — using filters while recording +**Speed mode**  allows you to select the level of 100% speed and what it depends on:
-  * **None**  — filter disabled (records real values). +
-  * **Fast** — slight averaging (smoothes values). +
-  * **Slow** — large averaging.+
  
-Next, in the **# Data to log** menu sectionsyou can select the set of parameters you want to record. Select **On** to enable parameter recording.+  * **OFF**  — completely disables speed control PID. 
 +  * **Middle U bat**  — the average value between the minimum and maximum voltage of the battery settings used as speed referencedepending on motor kV. 
 +  * **U supply**  — supply voltage used as speed reference, depending on motor kV. 
 +  * **Ref. speed**  — speed in km/h, is set by parameter **Reference speed**. The speed value is taken from the motor or from an external speed sensor connected to the controller. 
 +  * **Ref. ERPM**  — speed in motor electric RPMis set by parameter **Reference speed**. 
 +**Minimum speed**  — in electrical revolutions per minute (ERPM). Select of values from **0 ERPM**  to **100000 ERPM**, in increments of **100 ERPM**.
  
-**# Data to log**: \\  +**Speed limat 0% throttle**  — enables limiting the speed when the throttle grip is completely releasedSelect of values **On**  and **Оff**. Selecting **Off**  disables motor control when the throttle is released.
-**Battery Voltage** — battery voltage data logging\\  +
-**Battery Current** — battery current data logging. \\  +
-**Motor Voltage** — motor voltage data logging. \\  +
-**Motor Current** — motor current data logging. \\  +
-**Wheel speed** — wheel speed data logging. \\  +
-**Throttle** — throttle grip data logging. \\  +
-**Brake** — brake lever data logging. \\  +
-**Motor rad/s** — data logging of the angular speed of the electric motor\\  +
-**Motor RPM** — data logging of revolutions of an electric motor per minute. \\  +
-**Tmotor °C** — data logging of the electric motor temperature. \\  +
-**Tfet °C** — data logging the temperature of field-effect transistors\\  +
-**Raw hall input** — data logging the input status from Hall sensors without filter. \\  +
-**Hall index** — virtual position of motor. \\  +
-**FOC Vq** — Q-axis voltage data logging. \\  +
-**FOC Vd** — D-axis voltage data logging. \\  +
-**FOC Iq** — Q-axis current data logging. \\  +
-**FOC Id** — D-axis current data logging. \\  +
-**Current phA** — data logging the current on the A phase of the electric motor. \\  +
-**Current phB** — data logging the current on the B phase of the electric motor. \\  +
-**Current phC** — data logging the current on the С phase of the electric motor.+
  
-===== Device information =====+===== Motor setup =====
  
-In the menu section **Controller** > **Device Information** you can view the basic information about the Controller. In this menu, you can check which firmware version is loaded into your Controller, as well as other parameters that differ depending on the Controller model\\+The **Controller**  > **Motor Setup**  menu contains all settings related to electric motor operation parameters.
  
-{{:en:controller:k34_en.png?nolink |}}+==== Motor temperature sensor ====
  
-**Micro Nucular Controller** — device name depending on the type of Controller. \\ +In the menu section **Controller**  > **Motor setup**  > **Motor t°-sensor**  you can select a temperature range in which a smooth power limit will occur (**Delta °t**  parameterand specify the maximum temperature (**°t max**).
-**Max supply** — 95V. The warranty covers supply voltages up to **90V** inclusive. \\ +
-**Max current** — the value of the maximum phase current, depending on the type of Controller, in amperes (A). \\ +
-**Firmware date** — firmware compilation date. \\ +
-**Firmware ver.** — version of the installed firmware, you can check for updates in the section **[[en:firmware|Firmware]]**. \\ +
-**Loader date** — the data loader compilation date. \\ +
-**Loader version** — data loader version. \\ +
-**Worked** — operating time of the Controller in kilowatt-hours (kW*h). \\ +
-**t° middle 100 h** — the average temperature of the Сontroller over the last 100 hours. \\ +
-**t° middle** — the average temperature of the Сontroller over all time. \\ +
-**Current protections** — the number of triggered overcurrent protections over all time of operation of the controller. \\ +
-**Temperature protections** — the number of triggered temperature protections over all time of operation of the controller. \\ +
-**Voltage protections** — the number of triggered voltage protections over all time of operation of the controller. \\ +
-**Power cycle** — number of controller switching on. \\ +
-**Power-on time** — total operating time of the Controller, minutes, hours, days.+
  
 +{{:en:controller:temp_0808.png?nolink&  }}
  
-====== Controller (v.0.8======+**°t max**  — maximum electric motor temperature, in degrees Celsius (°C)Select of values from **50°C**  to **200°C**, in increments of **1°C**\\ **Delta °t**  — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning of the power limit, in degrees Celsius (°C). Select of values from **1°C**  to **100°C**, in increments of **1 °C**.
  
-The controller allows you to control BLDC (Brushless Direct Current Motorand PMSM (Permanent Magnet Synchronous Motorelectric motorsAt the moment we are producing three types of controllers for different motors power.+In the menu item **Sensor type**  you can select the following types of temperature sensors that support the controller — **KTY81(82)**, **KTY83**, **KTY84**, **NTC10K (B:3950)**, **NTC10K (B:3380)**, **PT1000**To disable the temperature control, select the value **OFF**.
  
-//Technical specifications of controllers://+It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors and select the one that displays data the most closely to room temperature. The current measured temperature is displayed at **# Value °t**.
  
- Parameters  ^  Controller 6F v.2  ^  Controller 12F  ^  Controller 24F  | +The **# °t resistance**  menu item displays the resistance of the motor temperature sensorwith an accuracy of /-10%.
-^Maximum power|  4 000W  |  10 000W  |  20 000W  | +
-^Nominal power|  2 000W  |  5 000W  |  10 000W  | +
-^Voltage range|  20-90V  ||| +
-^Phase currentmax|  120A  |  250А  |  500А  | +
-^Battery current, max|  ~90A  |  ~150A  |  ~300A  | +
-^Supply out|  12В 3A  ||| +
-^Operating temperature range|  -30°C до 80°C  ||| +
-^Phase wires|  11AWG 5mm bullets  |  8AWG XT150  |  7AWG terminals M6  | +
-^Battery wires|  12AWG XT60  |  10AWG XT90  |  8AWG terminals M6  | +
-^Hall connectors|  2.8mm 6P auto or Juliet waterproof  ||  Auto waterproof 6P  | +
-^Wires length|  140 mm  |  190 mm  || +
-^Control modes|  Square, sensorless, FOC, charger  ||| +
-^Protection|  Temperature and hardware overcurrent protection  ||| +
-^Sleep current less|  <300uA  ||| +
-^Protection class|  IP57 (IP67 with compound)  ||| +
-^Size, without wires|   53х32х91 mm  |  86х43х125 mm  |  86х43х185 mm  | +
-^Weight|  280g (with compound 430g)  |  640g (with compound 890g)  |  1100g (with compound 1450g) +
-^Warranty|  2 years (with compound potting — 3 year)  |||+
  
-//In the kit: //+==== Clutch ====
  
-  CAN-cable 1,2-meters length for connection to the On-board Computer.\\ +In the menu section **Controller**  > **Motor Setup**  > **Clutch**  you can configure a smooth engine launch for soft engagement clutch or freewheel. Useful for gear motors or mid-drivesAt the moment, the setting works well only in the control mode **Torque**, because the clutch there is always engagedAn alternative option is to configure the acceleration limit in the modes **S1**, **S2**, **S3**  in the menu section **Controller**  > **Advanced modes**.
-  Phase wires.\\ +
-  Battery wires\\ +
-  Hall sensors wire.+
  
-Phase, battery, and Hall sensors wires are supplied with connectors, depending on the type and specification of the controller in the order.+{{:en:controller:k16_en.png?nolink&  }}
  
-//Optionally you can order://+The parameter **Mode**  determines the way of operation:: \\ **Accelerate**  — smoothly accelerates the motor until the load appears. \\ **Accelerate and hold**  — in addition to the previous one, it applies weak torque to the motor after the throttle is released, this mode allows you to switch speeds at mid-drive systems without using the pedals.
  
-  САN-cables 0,3 and meters length.\\ +**# Phase amps** \\ **Start time**  — maximum time for soft start, in seconds (s). Select values from **1s**  to **20s**, in increments of **1s**. \\ **Start current**  — phase motor current at which the load will be detected and the soft start is disabled, in amperes (А). Select values from **0.2А**  to **50.0А**in increments of **0.2А**. This value must be higher than the phase current for specified acceleration of the motor without load. \\ **Detection time**  — the time during which the load must be present, after which the soft start will be switched off, in milliseconds (ms). Select values from **10 ms**  to **1000 ms**, in increments of **10 ms**. \\ **Acceleration**  — value in volts/seconds (V/s). Select values from **2V/s**  to **1000V/s**, in increments of **2 V/s**. The higher the value, the more you need to specify **Start current**, since the motor will consume more current during acceleration. \\ **Hold (20%)**  and **Hold (80%)**  — two parameters regulating the phase current supplied to the motor in the mode **Accelerate and hold**, in amperes (А). **20%**  — current at low speeds, **80%**  — current at about maximum speed. It is possible to determine the approximate values ​​by the no-load current of the motor. Select values from **0.2А**  to **50.0А**, in increments of **0.2А**. \\ **Hold enable time**  — time through which after the throttle has been pressed, torque hold will become available, in seconds (s). Select values from **1s**  to **120s**, in increments of **4s**.
-  Controller-side inputs for connection throttlebrakes levers directly to the Controller.\\ +
-  PWM/PAS wire for connection PASfans for cooling or brake lights.\\+
  
-===== Connection diagram =====+**Hold time**  — the time during which torque will be applied after releasing the throttle, in seconds (s). Select values from **1s**  to **120 s**, in increments of **1s**.
  
-First, connect the three phases of the electric motor. It does not matter in which order and by which color you connect the phasesthe controller will automatically detect them during auto-setup. Nextconnect the hall connector as shown in the diagram below. You also need to connect the throttle lever and battery power. We also recommend connecting the brake levers, as their actuation turns off the motor. A simple rule — in any incomprehensible situationpress the brake.+<WRAP center round tip 60%> \\ Optimal settings for MAC motor: **Accelerate**15a50V/s200ms.</WRAP>
  
-When the power is turned on for the first time, the controller will start automatically. To enable/disable the controller, you must connect an external switch according to the diagram or configure the button located on the back of the On-board computer in the menu **Devices** > **Controller** > **Extra parameters** > **Disable button**.\\+==== Setup the motor position sensors ====
  
-You can find the wiring diagrams of the other devices on this [[https://drive.google.com/file/d/1KkEgWcJ5U-AEkk6GrXhDNlYXFCcsjpUQ/view|link]]. By default, all peripherals (throttle, brake, switches, etc.) are connected into ports located on the backside of **[[en:display:start|On-board computer]]**. To access the ports, you need to unscrew five screws and remove the plastic cover. For connection, use PHD 2.0 connectors and crimp pins, which are included in the kit. If you do not have a crimping tool such as Crimper SN-2549, you must order "Crimped wires for display". The On-board computer is connected to the controller with one CAN-wire 1.2 meters long, which is included in the controller kit. Be carefulthe CAN-wire from the Controller is connected to the **SYSTEM** connector on the backside of the On-board computer.+Under the menu section **Controller**  > **Motor setup**  > **Position sensors**, you can find the menu items for configuring the position sensors of the electric motorAt the moment, the Controller supports two types of sensors — Hall sensors and a rotation angle sensor (encoder).
  
-If you want to connect peripherals directly to the Controller, you need to order "Control-side inputs", in the diagram below this switching option is designated as "Alternative connection"You can also use a mixed connection, for example, connect the throttle lever to the On-board computer, and the brake lever to the Controller.\\ \\+{{:en:controller:hall_0908.png?nolink&  }}
  
 +**Sensor type**  — Parameter needs reboot if manually changed. There are currently two types of sensors available: \\ **Hall**  — Hall sensors. \\ **Encoder**  — rotation angle sensor.
  
-{{:en:controller:nucular_controller_manual_eng_for_wiki.png?nolink |}} +**Sensor mode**  — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes\\ **Sensorless**  — motor control using BEMF integration, parameter **Integration threshold**  is used. It is rather insensitive to tuning, but more accurate tuning may be required for high-speed motors (such as RC). At the moment, the sensorless does not have a start-up algorithm, it works stably only at some speed. Hall setups start with sensorless mode. \\ **Combined**  — start the motor on Hall sensors, then switch to sensorless mode, the threshold is determined by the parameter radians per second (**rad/s**) in the **From hall to s-less**  menu item. Select of values from **0.00 rad/s**  to **2.00 rad/s**  in increments of **0.05 rad/s**. To convert values keep in mind that 1 rad/s to RPM = 9.5493 RPM. \\ **Sensors**  — electric motor control only by signals from Hall sensors. \\ **Freq**  — frequency control. Do not use this mode for driving!
-~~CL~~ \\+
  
-===== Connecting multiple controllers =====+**Interpolate sensors**  — smooth change of the sensors angle based on speed. Used for FOC mode. Select of values **On**  and **Off**.
  
-If you want to connect two or more Controllers, you can use CAN splitter with four ports (purchased separately) or a lighting controller [[en:ulight|uLight]]which also has three own CAN portsThe On-board computer supports the connection of up to eight Controllers\\+**Interpolation start**  — the motor is always started from discrete angleif digital halls are usedAfter the specified speed, the angle starts to change smoothly. Select of values from **0 rad/s**  to **100 rad/s**, in increments of **1 rad/s**.
  
-For example, for two-motor connection scheme, which is used on all-wheel-drive electric scooters, in addition to the second controller, you will need a CAN-splitter and one more CAN wire (there are 2, 1.2, and 0.3 meters long). Each Controller has a standard CAN-wire 1.2 m longThese wires from both controllers must be connected to a CAN-splitterand from it one CAN-wire connects directly to the On-board computer. In the On-board computer, you can configure both controllers are separate.\\+**Frequency control**  — separate mode that can be used to power equipment through a transformer or to dry the varnish on the motor windingsSelect of values from **10 HZ**  to **200 HZ**in increments of **1 HZ**.
  
-<WRAP center round important 60%>\\ +==== Hall sensors setup ====
-Pay attention to the connection diagram. ** Do not disconnect power grounds when system wires are connected! ** +
-First connect all power wires and only then CAN wires. When disconnecting the controllers, first disconnect all CAN wires and only then disconnect the power cables; it is also recommended to discharge the controller capacitors with a resistor or an ordinary light bulb. +
-</WRAP>\\+
  
-{{:en:controller:multiplay_en.png?nolink|}}+Further in the menu section **Controller**  > **Motor Setup**  > **Position sensor**  > **Hall settings**  there are items for additional setting of Hall sensors.
  
 +{{:en:controller:hall_en_0504.png?nolink& |}}
  
-====== How to start? ======+**Hall filter**  — enable or disable the filter in the direction of rotation, select the **Direction**  and **OFF**  values.
  
-After you have connected the Controller and Controls according to the diagramyou need to configure the battery parametersFor this, go to the **Settings** **Devices** sectionselect the Controller in the list of devices, then go to the **Controller** > **Battery** section and specify the supply voltage rangeFor a detailed description, see the section [[en:controller:setup#battery|Battery]]\\+**State filter**  — select the delay timein seconds (sec)Selection of values from **0.000s**  to **1.000s**, in increments of **0.002s**. This delay is used if the wrong value of the Hall sensors is receivedAll indicators that are less than the set value will be filtered out.
  
-{{:en:controller:k1_en.png?nolink|}}+**Direction filter** — select the delay time for changing the direction of rotation of the electric motor (forward/backward), in seconds (sec). Selection of values from **0.000s**  to **1.000s**, in increments of **0.002s**.
  
-After configuring the batteryyou need to run Auto-setup in the **Controller** **Auto-setup** menu section. Ensure that the phase and battery wires are well contacted and insulated before running auto-setup. Check that the Hall sensor wire connectors are fully inserted into the mating parts. For detailssee the section **Auto-setup**. After auto-setup, you need to adjust the speedometer to display the speed correctly, see the section [[en:controller:setup#speedometer_setup|Speedometer setup]].+**Idle filter** — when the motor is not movingthe sensor position is reset to the middle position. Selection of values from **10ms** to **1000ms**, in **5ms** increments.
  
-====== Menu navigation ======+The next menu sections shows the Hall indices and Hall angles for the two directions of rotation of the electric motor. These indices are used for the internal operation of the Controller.
  
-Use the On-board computer buttons to navigate through the menus. Left button — return to the previous menu or cancel editing. Right button — go to the menu section and confirm the parameter selection. The two middle buttons — to move up/down through the menu and select the value of the menu item.\\+~~CL~~
  
-===== Settings saving =====+==== Manual setup the Hall sensors angles ====
  
-In the menu item **Controller** > **Save settings** you can save all the settings made. Press the right button of the Onboard-computer and select **On** to save. If you do not save the settings, they will be reset after restart\\+In general, it is not recommended to change these settings manually! \\ In the menu section **Controller**  > **Motor settings**  > **Manual angle setup**  you can set up the Hall sensors angles of the electric motor.
  
-===== Auto-setup =====+{{:en:controller:k17_en.png?nolink&  }}
  
-The auto-setup function in the **Controller** **Auto-setup** menu section allows you to automatically set up the electric motor, throttleand brake levers.+**Offset for square**  — additional shift for square wave mode, in degrees (**°**). Select of values from **-30°**  to **30°**, in increments of **1°**. \\ **Offset total fwd**  — shift all Halls sensors by the specified value for the direct rotation of the motor, in degrees (**°**). Select of values from **-60°**  to **60°**, in increments of **1°**. \\ **Offset total bkwd**  — shift all Halls sensors by the specified value for the reverse rotation of the motor.in degrees (**°**). Select of values from **-60°**  to **60°**in increments of **1°**.
  
-{{:en:controller:1_0.8.png?nolink }}+To shift all the halls, you must press the right button of the On-board computer, enter the shift angle, press the right button againThe value will be reset and the angle of all halls will change to the specified value. You can change the angle of the hall shift in the opposite direction by setting a negative value.
  
-The auto-setup menu starts the subprogram and shows only the processAll settings are saved under **Controller** **Motor setup**. After restarting the Controllerall switches will be in the **Off** position.+**Reset angles**  — reset of all Hall sensors angles. Select of values **On**  and **Off**\\ **Integration threshold**  — analogue of Hall angles for sensorless engine control mode, in volts (**V**)\\ **Hall adjust Ki**  — the meaning of the coefficient is to find the midpoint of the position of the Hall sensors when adjusting them. Values from **0.02**  to **5.00**, in increments of **0.02**. If the value of the coefficient is too small, then the tuning process will end before the midpoint is determined. If the value of the coefficient is too large, then the setting will not be completed and will stop by timeout, because the midpoint will not be found due to the angles changing too often.
  
-Once you have specified the battery supply voltage in the **Controller** > **Battery** section, you can proceed to calibrate the motor and levers in the Auto-setup section.+==== Encoder setup ====
  
-Before auto-setup the angles, we recommend specifying the correct number of motor pole pairs in menu item **Controller** > **Auto-setup** > **Pole pairs**. See **[[[:en:motor_information|Motor information]]** for this number for the most popular motors. If your motor is not on the list, check with the manufacturer or search the Internet for information.\\ +In the menu **Controller**  > **Motor Setup**  > **Position sensor**  > **Encoder settings**  there are menu items for configuring the motor encoder. The parameter values in each of the items will appear after passing through the Auto-setup procedureControllers with encoder capable have orange phase wires and an encoder speed of 580kHZ under **Controller**  > **Device Information**. The wire for connecting the electric motor with the encoder is ordered separately and is installed instead of the wire with connector for the Hall sensors.\\ 
-\\ +**Note:** on older controllers encoder use **P1** input as PWM for initial position detectionsetup ports **P1 (I5)** and **P2 (I6)** to **OFF** and disable PWM output. Settings applied after reboot.
-<WRAP center round important 60%>\\ +
-**Be careful! Before running autotuning, check that the drive wheels of your e-bike are not touching the surface and that the pedals (if equipped) do not touch anything when spinning. When adjusting the Hall sensors, the motor rotates in both directions, be careful and do not stand near the bicycle pedalsThe motor will rotate five timesonce when the motor is detected and four times when correcting the angle.** +
-</WRAP>\\+
  
-If you have a throttle lever and an analog brake connected, then you need to enable Full Setup, and follow the instructions on the On-Board computer screenThe corresponding menu items will indicate when to press and release the throttle or brake lever.+Wiring and connectors Compatibility: \\ **Halls**  > **Encoder**  — if your controller has a connector for Hall sensors, then you can make an adapter for the encoder yourselfBut, in this case, you will not be able to move when you turn it on, you will need to push the electric bike with your feet to start first time. \\ **Encoder**  > **Halls**  — if your controller has an encoder connector, then you can make an adapter for Hall sensors yourself. Everything will work.
  
-If only one throttle lever is connected, you must independently turn on the items step-by-stepThrottle, Motor, Angle correction. When you enable each of the menu items, the hints will be displayed. Auto-setup function **Motor LR** detects the inductance and resistance of the motor. You can see the measurement results in the menu section **Controller** > **Motor setup**, items **Phase resistance**, **Inductance d** and **Inductance q**.+{{:en:controller:encoder.png?nolink&  }}
  
-If the motor is heavy and autodetect does not happenyou can gently push it with your hand or increase the tuning current in the **Controller** **Auto-setup** **Setup current** sectionfor exampletwice. The setup current can be selected in the range from **2A** to **50A**, in increments of **1A**.+**Steps**  — number of encoder stepsselectable in increments of **1**. \\ **# Invert counter**  — select of values **Off**  and **On**. \\ **# Invert PWM**  — select of values **Off**  and **On**. \\ **# Index Z**  — the value of the additional output signal of the encoder (zero pointer)the choice of values from **0**  to **7**, in increments of **1**. \\ **# Shift Z FW**  — signal shift, select of values from **-60°**  to ** 60°**  in increments of **1°**. \\ **# Shift Z BW**  — signal shiftselect of values from **-60°**  to ** 60°**  in increments of ****.
  
-If the motor is rotating in the wrong direction, go to **Controller** > **Auto-setup** > **Spin direction** and change the direction of rotation. You can choose from two options **Forward** or **Invert**. A similar setting is available in the **Controller** > **Motor setup**> **Spin direction** menu. It doesn't matter in which menu you make the setting, after saving, the direction of rotation will be reversed in both sections.+== Debug information ==
  
-If an error occurs during autotuning, see the section **[[en:controller:diagnostics|Diagnostics of controller malfunctions]]**. In the menu item **Controller** **Auto-setup** **Control source** you can select the sources of control for the Controller. See Control Source section below for details**.** \\+**Index**  — encoder index signal value\\ **Z-Index**  — the value of the zero pointer. \\ **PWM Period**  — PWM signal period, in microseconds (**µs**). \\ **PWM Width**  — PWM signal pulse width, in microseconds (**µs**). \\ **Rad by index**  — position of the electric motor by index, in radians (**rad**). \\ **Rad by PWM**  — position of the electric motor by PWM, in radians (**rad**).
  
-===== Firmware update =====+==== Motor parameters ====
  
-In the menu section **Controller** > **Settings and Update**you can update the Controller's firmware, reset settings, import or export a configuration. You can upload all controller settings to a microSD card. The created file with the name **NCconf.cfg** - **NCconf9.cfg** you can open with the "Notepad" program, see all your settings, make any changes, save. Likewise, you can import a previously saved configuration into the Controller. Trip computer settings cannot be exported or imported. On-board computer settings can be exported and imported in separate [[en:display:start#import_and_export_of_settings|sections]] of the Onboard computer menu. This function is only available in the On-board computer firmware version **0.7B** and higher.+Items in the **Controller**  > **Motor setup**  menu section allow you to configure the parameters of the electric motor.
  
-{{:en:controller:k3_en.png?nolink |}}+{{:en:controller:motor_en_0504.png?nolink|}}
  
-**Import config.** — loads the settings from the file ** NCconf.cfg ** - ** NCconf9.cfg ** up to a maximum of 9 different configurations, choosing a file number from 1 to 9. After a successful import, error messages may appear in the message, this means that not all the settings have been importedIn this case, it is advisable to check the downloaded settings with the original file by opening it in Notepad.\\ \\ +**Pole pair**  — the number of magnetic pole pairs of the rotor of the electric motor determines the speed at which the motor shaft will rotateThis parameter is used to calculate RPM and speedFor more accurate autodetection of the Hall sensors angles, you must specify the correct value for the number of pole pairs for your motorFor the most popular motorsyou can see this value in the table **[[:en:motor_information|Motor Information]]**. If your motor is not listed in the tablecheck with the manufacturer for the number of pole pairs.
-**Export config.** - saves the settings to the ** NCconf.cfg ** - ** NCconf9.cfg ** file up to maximum of 9 different configurations, choosing a file number from 1 to 9.\\ \\ +
-**Reboot** — restarts the device. If the settings have not been savedthey will be reset.\\ \\ +
-**Reset Wh usage** — resets the accumulated number of Watt-Hours in the controller. This indicator is displayed in the statistics of the On-board computer, see section **[[en:display:start#statistics|Statistics]]**.\\ \\ +
-**Reset stats** — resets mileage in kilometers.\\ \\  +
-**Load defaults** — after a reset, the default settings are loaded but not saved. If you restart the Controller without saving after a reset, the previous settings will be loaded.\\ \\  +
-**Erase data storage** — This function may be needed for the correct firmware update, rollback to default settings, in a situation where user actions lead to incorrect operation of the ControllerIf the controller has stopped saving the settingsdo a reset, wait 3 seconds, and try to save again.\\ \\  +
-**Update firmware** — starting the firmware update process. You can download the current firmware version and read the rules of update in the **[[en:firmware|Firmware]]** sectionTo updatedownload the firmware file to the root directory of the microSD card with the Fat/Fat32 file system. Insert the card with the contacts facing up into the slot on the On-Board Computer and select ** On **. When the update process is complete, a message appears on the screen **Update finished**. Press the left button and check the update version under **Controller** > **Device Information**.+
  
-===== Control modes =====+**Spin direction**  — this setting allows you to change the direction of rotation of the electric motor. Select of values **Forward**  and **Invert**. Or you can swap two motor phases to change the direction of rotation.
  
-In the menu section **Controller** > **Control modes** you can configure and save three presets of the parameters of the electric motor and switch between them using a 3-position switch or buttons on the On-board computer. The currently active mode number is displayed at the top of the main screen. After settingit is necessary to activate the modes in the menu item **Controller** > **Additional modes** > **Enable additional modes** by setting the value **On**. In the same menu **Controller** > **Additional modes** you can make detailed settings for each mode (see the section Additional modes).+**Integration thr.**  — the analog of Hall sensors angles for sensorless motor control mode, in volts (**V**).
  
-If there is no speed switch, then mode is the defaultIf the switch is connected to the On-board computerit is necessary to configure the On-board computer buttons in the **On-board computer** **Button settings** menuSee section **[[en:display:start#buttons_setup|Buttons setup]]**.+**Control mode**  — this parameter is loaded at start-up and can be savedAt the moment, the Controller has the following motor control modes: \\ **Off**  — control mode is disabled. \\ **Square**  — outdated control method used only for motor detection\\ **FOC**  — field-oriented control of the motor. \\ **DC-DC**  — charging mode when you use the controller in motor charging mode.
  
-==== Modes setup ====+The control mode selected in this menu is the priority setting for the controller. If the Hall sensor mode is selected in the **Controller**  > **Motor setup**  > **Position sensor**  menu, which does not correspond to the set operating mode of the electric motor, then this Hall sensor mode will be automatically replaced with a more suitable one.
  
-{{:en:controller:9_0.8.png?nolink |}}+**Max motor U**  — limits voltage supplied to the motor, in volts (**V**)In most cases, this parameter is not needed. Select of values from **0V**  to **100V**, in increments of **1V**.
  
-The ** # Current mode ** line displays the currently selected control mode. List of possible options: \\ +**kV**  — motor parameter, electric revolutions per volt (**eRPM/V**).
-**N** — neutral. \\ +
-**S1** — speed 1. \\ +
-**S2** — speed 2. \\ +
-**S3** — speed 3. \\ +
-**RV** — reverse\\+
  
-Four parameters are used to configure each mode: \\ +Next are the menu items for configuring the MTPAthis function allows you to introduce a negative id current to increase the torque on the IPM motors.
-**Phase** — the maximum value of the phase currentin Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. When setting, consider the maximum phase current of your controller type. In most cases, we recommend specifying the value of the phase current 1.5-2 times higher than the battery current.\\+
  
-**Battery** — the maximum value of the battery current, in Amperes (**A**). Select of values from **2A** to **400A**, in increments of **2A**. When setting up, consider the capabilities of the connected battery and the maximum battery current of your controller type.\\+**Phase resistance**  — the result of measuring the phase resistance of the electric motor during auto-setup (menu item **Motor LR**), in Ohms (Ohm).
  
-**Power** — maximum power (discharge) of the battery, in kilowatts (**kW**). Select of values from **0.00kW** to **30.0kW**, in increments of **0.1kW**. Set to 0.0kW to disable the power limiting limit.\\+**Inductance d**  — the result of measuring the inductance of the electric motor along the d axis during auto-setup (menu item **Motor LR**), in microHenry (µH)The d-axis ("straight") refers to the component of the stator magnetic field that is in phase with the rotor magnetic field.
  
-**Speed** — maximum speed in percentage (%). Select of values from **4%** to **150%**, in increments of **2%**. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en:controller:setup#speedometer_setup|Speedometer setup]]**). A speed value over 100% activates the field weakening mode, which allows the motor to accelerate above the supply voltage. (see section **[[en:controller:setup#field_weakening_setup|Field weakening setup]]**).\\+**Inductance q**  — the result of measuring the inductance of the electric motor along the q axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The q-axis ("quadrature") refers to the component of the stator magnetic field that is 90 ° out of phase with the rotor magnetic field.
  
-==== Electric brake setup ====+**Flux linkage**  — is the total magnetic flux permeating the electrical circuit, in Weber (Wb).
  
-**Braking phase** — the value of the phase current of braking by the motor, in Amperes (**A**). Select of values from **0A** to **500A**in increments of **2A**. For braking to zero, it is recommended to enable **Active braking** in the section **Controller** > **Control**. When using the switch brake, lower brake current change speed makes recuperation more smooth. \\+**MTPA (IPM Motor)** — enable (**On**) the MTPA function for IPM motorfor all other motors this function must be disabled (**Off**)
  
-==== Braking phase at speed control ====+**FOC Vq limit** — improves field weakening on some motors. Select of values **On** and **Off**.
  
-**Braking ph. at speed** — phase braking current during speed control, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows you to slow down when you reset the throttle stick. Works only with Direct Drive motorswithout a clutch\\ +**# Square wave settings:** \\ **Square offset**  — additional shift for square wave mode, in degrees (°)Select of values from -30° to 30°, in increments of 1°. This item is similar to the same item in the menu **Controller**  > **Motor setup**  > **Position sensor**  > **Manual angle setup**. \\ **Boost square current**  — in the sensorless or square mode, applies 100% PWM at the beginning of each winding switch. Starting from specified speed and minimum requested current. Select of values **On**  and **Off**. \\ **Boost current**  — setting refers to the control mode **Square**, the minimum current from which the rapid current pumping in the windings is turned on, in amperes (**А**). Select of values from **0A**  to **100A**, in increments of **1A**. \\ **Boost speed**  — setting refers to the control mode **Square**the minimum speed after which the rapid pumping of current in the windings is turned on, in radians per second (**rad/s**). Select of values from **0.00rad/s**  to **2.00rad/ms**  in increments of **0.05rad/s**.
  
-Also to use this mode should be selected: +===== Battery =====
-**Speed** or **Speed and Torque** mode in the **Controller** > **Control** > **Throttle Mode** menu item. +
-In the menu item **Controller** > **Control** > **Speed lim. at 0% throttle** enable the speed limit at 0% throttle (optional), enable if you need braking with completely released throttle. \\+
  
-==== Regenerative braking setting ====+In the **Controller**  > **Battery**  menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V**  to **90V**, this is **21S**  for Lithium-ion (Li-ion) batteries and **25S**  for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[:en:display:start#battery_capacity|settings]] of On-board Computer. If you use several batteries with different parameters on the same bike, you can save the configurations for each battery on the SD card and load them after replacing the battery. The SD card can be stored in the On-board computer.
  
-**Braking phat 0% throttle** — phase braking current with the throttle handle released, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. \\+{{:en:controller:k20_en.png?nolink&  }}
  
-This function will be active if additional modes are disabled in the **Controller** > **Advanced modes** menu section or ifwith activated additional modesin one of the menu sections **Mode S1****Mode S2** or **Mode S3** in menu item **Braking phat 0% throttle** was setup is **0A**. +**Full charge**  — delta voltage relative to the maximumat which when the controller is turned onwill reset the watt-hour consumption, in volts (**dV**). This setting resets the **From charge statistics**  when the Controller is turned on. Select values from **0.00 dV**  to **10.00 dV**, in increments of **0.3 dV**.
-==== Reverse setup ====+
  
-**Speed reverse** — reverse speed, in percentage (%). Select of values from ** 2% ** to ** 150% **, in increments of ** 2% **The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en:controller:setup#speedometer_setup|Speedometer setup]]**)A speed value over 100% activates the field weakening modewhich allows the motor to accelerate above the supply voltage (see section **[[en:controller:setup#field_weakening_setup|Field weakening setup]]**).\\+**Supply max**  and **Supply min**  — battery voltage range, in volts (**V**). Select values from **20.00V**  to **95.00V**, in increments of **0.1V**. Alsothese settings are used for the **Converter**  mode.
  
-**Phase reverse** — the value of the reverse phase currentin Amperes (**A**)Select of values from **10A** to **500A**, in increments of **2A**.\\+For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**. \\ For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**.
  
 +<WRAP center round important 60%> We guarantee stable operation of the Controller at voltages up to **90V**  inclusive. Using a battery over 90V may damage the Controller and void the warranty. </WRAP>
  
-==== Field weakening setup ====+**Charge max**  — maximum battery charging current, during regeneration or in **Converter**  mode, in amperes (**А**). Select values from **1.0A**  to **400.0А**, in increments of **0.5А**.
  
-**Field weakening** — the magnitude of the field weakening current, in Amperes (**A**). Select of values from **0A** to **500A**,  in increments of **2A**This setting allows you to increase the maximum motor speed and depends on the supply voltage, in any case, the speed will be no more than the maximum supply voltage (**Vmax**) of the controller (**95V limit**).\\+**Discharge max**  — maximum continuous discharge current of the batterybut in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A**  to **400.0А**, in increments of **0.**.
  
-<WRAP center round info 60%>\\ +**Power max**  — maximum continuous discharge power, in watts (**W**)Set 0W to deactivate power limitSelect values from **0W**  to **30000 W**, in increments of **100W**.
-The current of weakening creates a field that acts against the field of the permanent magnetsThe superposition of these fields creates an equivalent field that is below nominalThe attenuation efficiency depends on the parameters of the motor. The best results can be obtained with IPM motors. +
-</WRAP>\\+
  
-To set up the weakening, you need: +**# DC voltage**  — current supply voltage of the Controller, in volts (**V**).
-  for one of the control modes in the section **Controller** > **Control modes** specify a speed value greater than 100%, for example, Speed 3 is 120%. +
-  * set the weakening current value in the section **Controller** **Control modes**, you can start from 30A.\\+
  
-Field weakening is activated when the maximum speed is reached, the Controller adds weakening current, limiting the phase current and weakening current specified in the control mode. That is if the effective phase current is 70A, and the weakening current is set to 30A, then a minimum of 100A must be specified in the phase current settings. If the phase current increases to 80A, then only 20A will remain for weakening because 80A + 20A 100A.\\+===== Converter =====
  
-Also, the Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery)If the motor starts twitching on the suspended wheelthen it is necessary to reduce the weakening current.\\+In the menu section **Controller**  > **Converter**, can configure charging mode from the power supply through the motor. Charging through the inductor is not currently supportedFor the power supply connection diagramsee this [[:en:controller:setup#connection_diagram|link]].
  
-==== Current change speed ====+{{:en:controller:k21_en.png?nolink&  }}
  
-**# Current change speed**.  +**Enable**  — turn on the converter mode and start chargingSelect of values **On**  and **Off**.
-  * acceleration, select of values from **50A/s** to **50000A/s**, in increments of **100A/s**. +
-  * braking, select of values from **50A/s** to **50000A/s**, in increments of **100A/s**. +
-  * shutdown, select of values from **50A/s** to **50000A/s**, in increments of **100A/s**.\\+
  
-Three parameters determine the rate of change of the current (smoothness). The higher the value, the faster the current build-up in the motor will occur. For conventional brake levers, it will be useful to reduce the parameter **braking** for a smoother activation of the regeneration. If the throttle response seems too slow, you need to increase the parameter **acceleration**. The parameter **shutdown** determines how quickly the current drops after throttle and brakes are released.+**Auto-enable**  — allows the automatic start of charging when the charging PSU is connected to the controller. Select of values **On**  and **Off**.
  
-===== Advanced control modes =====+**Detection threshold**  — minimum voltage on phases when charger mode activates, also disables motor control, in volts per phase (**Vph**). Select of values from **10Vph**  to **80Vph**, in increments of **1Vph**.
  
-In the menu section **Controller** **Advanced modes** enables the control modes and activates the advanced settings for each of these modes.\\+**Battery max I**  — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А**  to **100.0A**, in increments of **0.5А**.
  
-{{:en:controller:k5_en.png?nolink |}}+**Battery min I**  — minimum charge current when current is decreased by voltage, in amperes (**А**). Select of values from **0.5А**  to **10.0A**, in increments of **0.5А**.
  
-To activate the control modes, select **Controller** **Advanced modes** **Enable addmodes** and to set **On**. \\+**Undercharge**  — voltage relative to maximum battery voltage setup, in volts (**V**). Let's decrease the full charge voltage. Select of values from **0.00V**  to **10.0V**, in increments of **0.1V**.
  
-In the menu **Controller** **Advanced modes** **Neutral by default** you can activate the neutral mode (Nwhen the controller starts up, which will be active until one of the speed modes is activatedIn a neutral mode, only the electric brake operates, throttle and PAS are disabled. This mode is recommended for use with speed buttons (not a switch). The function does not work with a 3-position switch (functions of the S1of3 and S3of3 ports in the **Controller** **I/O configuration** menu)​\\ +**Current drop delta**  — decreases charging current down to **Battery min I**  as the battery reaches maximum voltage on specified voltage range, in volts (**dV**). Select of values from **0.0dV**  to **20.0 dV**  in increments of **0.5 dV**.
-~~CL~~ \\+
  
-Each mode has its own section in the **Controller** **Advanced modes** **Mode S1Mode S2, Mode S3 ** with the following settings: \\+**Supply max I**  — maximum power supply current, in amperes (**А**). Select of values from **2.0 A**  to **150.0 A**, in increments of **0.5 A**.
  
-{{:en:controller:5_0.8.png?nolink |}} +**Supply drop U**  — allowable voltage drop on wires or power supply, in volts (**V**). Select of values from **0.50 V**  to **10.00 V**, in increments of **0.25 V**.
-**Throttle mode** — selection of the operating mode of the throttle leverread more in the section **[[en:controller:setup#throttle_control_mode_setup|Throttle control mode setup]]**.\\+
  
-**Acceleration lim.** and **Deceleration lim.** — are specified in ERPM/s, select of values from **0 ERPM/s** to **500000 ERPM/s**, in increments of **200 ERPM/**. These settings allow you to limit the speed of acceleration or deceleration of the motor, it is convenient to use on slippery surfaces. For setting go to the **Controller** > **Status flags** section, in this menu there are two parameters that register the maximum acceleration and deceleration — **Max acceleration** and **Max deceleration**. **Reset** the values of these parameters in the same section of the menu, then you need to ride your e-bike in order to register the current dynamics of acceleration and deceleration. You can use these values as a reference and decrease them if you need to limit change speed. If the type of surface changes, for example, it becomes too slippery, then these values can be reduced until it becomes comfortable to catch the moment when the wheel loses traction. \\+**Max motor t°**  — setting the limitation of the heating temperature of the motor during charging, in degrees Celsius (**°C**). Select of values from **50°C**  to **120°C**, in increments of **5°C**.
  
-**Braking ph. at 0% throttle** — phase braking current with the throttle handle releasedin Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. If **0A** is specified or additional modes are disabled in the **Controller** **Advanced modes** section of the menu, then for the recuperation level will be used value from menu item in the **Controller** **Control modes** > **Braking ph. at 0% throttle** menu item. +Below in the menu sectionthrough the **#**  signthe real-time values of voltages and currents are shown: \\ **# Battery I** \\ **# Battery U** \\ **# Supply I** \\ **# Supply U**
  
-**Revers** — reverse gear activation when the control mode is selected. Select of values **On** or **Off**\\+After plugging in the power supply, the On-board Computer will display the battery charging process.
  
-**Cruise** — activation of the cruise function. Select of values **On** or **Off**. Convenient to use with cruise mode **Allow Throttle hold** in the menu section **Controller** **Control** **Cruise** **Cruise** to enable cruise in certain modes. See section **[[en:controller:setup#cruise_control_setup|Cruise control setup]]**. \\+{{:ru:controller:charging.png?nolink&  }}**Indication to the right:** \\ **-22.1A**  — information line parameter, depending on the On-Board Computer settings. \\ **0:0:58**  — time elapsed since charging started, hours, minutes, seconds. \\ **I24.9**  — charging current, in Amperes (**A**). \\ **U53.7**  — charging voltage, in Volts (**V**).
  
-**Disable motor** — completely disables motor control. Select of values **On** or **Off**. \\+**The indication in the middle**  is the temperature of the motor and the controller, respectively, in degrees Celsius (**°C**).
  
-**Disable throttle** — disable throttle controlSelect of values **On** or **Off**. \\+**Indication to the left:** \\ **59.0V**  — information line parameter, depending on the On-Board Computer settings. \\ **15Wh**  — the battery capacity in Watt hours (**Wh**). \\ **100%**  — the battery level, in percent (**%**). \\ **I24.9**  — the battery current, in Amperes (**A**). \\ **U53.7**  — the battery voltage, in Volts (**V**).
  
-**Active braking** — allow the brake to use the battery for stopping. Select of values **On** or **Off**. \\+~~CL~~
  
-**Reverse on brake** — after stopping, pressing the brake lever again activates reverse speed. Select of values **On** or **Off**. \\+===== I/O port configuration =====
  
-**Speed lim. at 0% throttle** — allows limiting the speed when the throttle lever is releasedSelect of values **On** or **Off**. Selecting **Off** disables motor control when the throttle is released\\+In the **Controller**  > **I/O configuration**  menu section, you can configure the ports functionsThe controller has eight digital ports that can be configured for different functions — **S1****S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M**. See section **[[:en:controller:setup#connection_diagram|Connection diagram]]**.
  
-**Disable PAS** — disables the Pedal AssistSelect of values **On** or **Off**. \\+Sixteen CAN ports are additionally available **CAN port 1**  - **CAN port 16**, the signal source for which can be configured on the On-board computer or uLightThese are software values, there are fewer physical inputs on the boards, at the moment there are eight CAN ports **IO1**  - **IO8**  available in the On-board computer plus four Hotkeys (buttons on the On-board computer). In the future, six CAN ports ** I1 **  ** I6 **  will be added to the uLight board.
  
-**PAS Scale** — extra PAS multiplier for tuning, decreases PAS signal for smoother control on high power modes. Select of values from **1%** to **100%**, in increments of **1%**.+{{:en:controller:ports_en.png?nolink&  }}
  
-===== Control ====== +In the section **Controller**  > **I/O configuration**  > **Port state**, you can check input activation when contact shorted to GND. When a signal is applied, the value will change from **Off**  to **On**. Below in the menu items **# Throttle**  and **# Brake**  you can see the voltage on the throttle and brake leversrespectively.
-In the **Controller** > **Control** menu section you can setup setting the engine controls, throttle levers, torque and PAS sensorscruise control.+
  
-==== PAS and Torque sensor setup ====+If the controls are connected to the On-board computer, then it is necessary to check the activation when contact shorted to GND in the **On-board computer**  > **Information**  [[:en:display:start#information|menu]].
  
-In the menu section **Controller** > **Control** > **Pedal Assist System** you can set up the Pedal Assist System (PAS), which connects the electric motor when pedaling. \\+~~CL~~
  
-ЧTo be able to connect the PAS system, it is necessary to order the PWM IO/PAS cable as an option. The PAS system connects to the Controller via the PWM IO/PAS wire to the **P1/P2** ports of the **USB/PWM** connector. When using a SEMPU pressure sensoran additional signal output from the TH port of the connector **Control** is required\\+In the item ** Controller **> **I/O configuration**  > **Speeds mode**  you can select the method for switching additional modes **S1**, **S2**, **S3**  for inputs in the Controller or CAN inputs - **Switch**  or **Buttons**.
  
-You can look at the connecting methods of various PAS systems at **[[en:controller:setup#connection_diagram|Connection diagram]]**\\+{{:en:controller:k24_en.png?nolink&  }}
  
-The PAS, unlike the Torque sensorcontrols the throttle by frequency and not by the force of rotationThe PAS setup menu consists of the following items: \\+Available functions for the Controller ports **S1****S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M**  and CAN ports **CAN port 1**  - **CAN port 16**: \\ **OFF**  — disable port. \\ **RV**  — reverse. \\ **CRe**  — enable cruise. \\ **CR **  — increment cruise speed (when cruise is active). \\ **CR-**  — decrement cruise speed (when cruise is active). \\ **CRr**  — restore last saved cruise speed with button, activated only above min cruise speed. \\ **BK**  — brake button. \\ **DM**  — disable motor (disable throttle, brake and PAS). \\ **DTH**  — disable throttle. \\ **DPAS**  — disable PAS. \\ **SWSNS**  — input for Gearsensor to reduce motor torque (WIP). In development. \\ **N**  — activates the neutral mode forcibly, resets speed mode counter if used. If neutral is activated by default, you need to change speed mode again to exit neutral. \\ **nBK**  — inverted brake button input, activates the brake when the contact is opened\\ **S1**  — speed 1. \\ **S2**  — speed 2. \\ **S3**  — speed 3. \\ **S1of3**  — speed 1 for 3-position switch. \\ **S3of3**  — speed 3 for 3-position switch. \\ **Scyc**  — cycle speed mode, sequential switching with one button. \\ **S **  — increment speed, switching the speed from low to high with one button. \\ **S–**  — decrement speedи, switching the speed from high to low with one button. \\ **SPSNS**  — input for external speed sensor. \\ **Spec.**  — special port function (like PWM or PAS). \\ **CL1**-**CL5**  — instant configuration import by pressing the CAN button (up to five different configurations). For correct import, the function number must match the number in the name of your configuration file. For example, a **CL3**  function would correspond to a file called **ncconf3.cfg**.
  
-{{:en:controller:k7_en.png?nolink |}} +Further in the menu, there are items for configuring the PWM outputs.
-**PAS** — selection of pedaling assistant type **PAS sensor** or **Torque sensor**. If there is no PAS system, select **Disabled**.\\+
  
-**PAS connection** — 1-wire or 2-wire connection option, two wires are used for the angle sensor (encoder). \\ +~~CL~~
-**Invert PAS** — change of direction in case of 2-wire connection. Select of values **On** or **Off**. \\ +
-**PAS poles** — number of impulses per pedal revolution. Select of values from **1** to **200**, in increments of **1**.\\ +
-**PAS min. freq.** — the minimum pedal speed (cadence) at which the motor starts, RPM. Select of values from **1 RPM** to **500 RPM**, in increments of **1 RPM**. \\ +
-**PAS max freq.** — the maximum pedal speed (cadence) at which the motor starts, RPM. Select of values from **10 RPM** to **1000 RPM**, in increments of **5 RPM**. \\+
  
-**# PAS freq.** — the value of the signal coming from the PAS in real-time. \\ +==== PWM output setup ====
-**PAS timeout** — the time after which the motor turns off after stopping pedaling, in seconds (s). Select of values from **0.02s** to **5.00s**, in increments of **0.02s**. \\ +
-**PAS filter** — smoothing the control signal for smoother operation, in hertz (Hz). Select of values from **1 Hz** to **100 Hz**, in increments of **1 Hz**. \\ +
-**PAS min out** — minimum control level when PAS is running, in percent (%). Select value from **0%** to **100%**, in increments of **1%**. \\ +
-**PAS max out** — maximum control level, in percent (%). Select of values from **0%** to **100%**, in increments of **1%**. By analogy with the “pressed” throttle, PAS sends a signal within the specified limits. \\+
  
-Further in the menu are the settings related to the pressure sensor (Torque sensor).\\+To activate the **PWM P1**  or **PWM P2**  output, the **Controller**  > **Port Setup**  menu should be set to **Spec.**  mode and **PAS**  disabled.
  
-**Pressure scale** — in Newton-meters/volts (Nm/V). You can calibrate by placing a load on the pedal and calculate the torque on the shaft through the lever. Select value from **0.0 Nm/V** to **100.0 Nm/V**, in increments of **0.5 Nm/V**. \\ +**PWM freq**  — selection of frequency of additional PWM output on ports **P1/P2**. Select of values PWM frequency — **100Hz****500Hz**, **1kHz****5kHz**, **10kHz**, **24kHz (FAN)**. For a conventional light bulb, large values are not needed. Select the frequency **100Hz**, this will be enough to avoid flickeringThe high frequency marked ** FAN **  is used to control the fanthis is their standard frequency.
-**Zero pressure** — zero pressure, in millivolts (mV). Select of values from **0mV** to **10000mV**, in increments of **10mV**. \\ +
- **Protection pressure** — switching off the pressure sensor when the threshold of the specified value is exceededin millivolts (mV). Select of values from **0mV** to **10000mV**, in increments of **100mV**. \\ +
-**Torque averaging** — period for which is torque value updated. Measured in half turns (turn/2). If the torque sensor measures only one pedalthen the period must be a multiple of twoSelect of values from **1 turn/2** to **20 turn/2**in increments of **1 turn/2**\\+
  
-**# Torque** — shows the current torque at the sensor, in Newton-meters (Nm). \\+**PWM P1**  and **PWM Р2**  — selection of operating modes:
  
-**# Human watt** — shows the average power you develop when pedaling, in watts (W)\\ +  * **Disabled**  — mode not selected. 
-**Human watt min** — the minimum power you develop to activate the motor, in watts (W). Select of values from **0 W** to **500 W**, in increments of **10 W**. \\ +  * **Stop-light**  — activated when the brake is pressed. 
-**Human watt max** — the maximum power for 100% activationin watts (W). Select of values from **0 W** to **1000 W**, in increments of **10 W**. \\+  * **Headlight**  — activated when the controller is enabled
 +  * **t°C motor**  — activated beyond the two deltas of the motor temperatureas the motor heats up will increase the PWM duty Delta °t set up on menu **Controller**  > **Motor setup**  > **Motor t°-sensor**). 
 +  * **t°C controller**  — activated from 40°С, maximum value at 80°С temperature of the Controller. 
 +**PWM Pn Min**  / **Max**  — indicates the output range of the PWM (duty), select of values from **0%**  to **100%**, in increments **1%**. \\ **PWM Pn t° Min**  / **t° Max**  — selection of motor or controller temperatureselect of values from **0°С**  to **100°С**, in increments **1°С**.
  
-**Torque min** —  the torque at which the throttle signal starts to increase, Newton-meters (Nm). Select of values from **0 Nm** to **100 Nm**, in increments of **2 Nm**. All values less than this level is 0% of throttle. \\ +===== Extra parameters =====
-**Torque max** — the torque, which limits the level of 100% throttle, Newton-meters (Nm). Select of values from **0 Nm** to **300 Nm**, in increments of **2 Nm**. \\ +
-**Instant Torque** — allows torque sensor activation without rotation. Select of values **On** or **Off**. The pressure sensor also includes frequency configuration and output level configuration as well as the usual PAS.+
  
-==== Remote control ====+In the menu section **Controller**  > **Extra parameters**  you can set up various additional settings of the Controller.
  
-The **Controller** > **Control** > **RC Control** menu section allows you to configure the remote control of the Controller using an external RC receiver. \\+==== The power button and auto shutdown ====
  
-{{:en:controller:k8_en.png?nolink |}}+The controller power button is located on the back of the On-Board Computer. In the **Controller**  > **Extra parameters**  > **Disable button**  menu item, you can select the way to turn on/off the Controller, which turns on when it is powers-up or the button contacts are closed. In the off mode, the controller consumes about 100 μA, so if you reconnect the power supply without discharging the capacitors, the controller may not start.
  
-Input for radio control via PWM (PWM), connects to the **P1** port of the **USB/PWM** connector on the Controller boardTo activate the function, select the **PWM** value in the **P1 Input Mode** menu item. \\+{{:en:controller:k25_en.png?nolink&  }}
  
-The **# Input Freq.** and **# Width** menu items show the current signal value in hertz (**Hz**) and milliseconds (**ms**)respectively. \\+Selecting modes for **Disable button**: \\ **None**  — the controller turns on when it is power-up up or when the power button is closed, does not turn off. \\ **Switch**  — the controller turns on when the power button is closed (when EN shorted to GND), turns off when it opens. \\ **Button**  — the controller turns on the button on the On-Board Computerpress it for 2 seconds, and release, to disable it, press and hold the button again. \\ **CAN**  — the controller turns on when it is powers-up or the button contacts shorts, disables only when another device on CAN bus will send a request to disable. This function is used when there are several controllers on a system, where one of them is set to button or switch mode, and the other in CAN mode.
  
-In the menu item **Function** selects the control function — **Off****Throttle****Brake** or **Throttle and brk**. \\  +**Auto shutdown**  — activation of the controller shutdown function after a while if the motor does not spin. Select of values **On**  and **Offл**. The shutdown time is set in item **Sleep time**.
-~~CL~~ \\ +
-Adjust the throttle and/or brake range as indicated by the signal.\\+
  
-**# Throttle range** \\ +**Sleep time**  — selection of the controller shutdown time when the **Auto shutdown**  function is activated, in seconds, (**s**). Select of values from **30s**  to **1500s**, in increments of **5s**.
-**Throttle min** — minimum throttle value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ +
-**Throttle max** — maximum throttle valuein milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ +
-  +
-**# Brake range** \\ +
-**Brake min** — minimum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ +
-**Brake max** — maximum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**.+
  
-==== Cruise control setup ====+**Lock at turn-on**  — the function locks controller inputs when enabled until the password is entered on the On-Board Computer, if there is no On-Board Computer, enabling this setting will permanently lock the controller.
  
-In the menu section **Controller** > **Control** > **Cruise** you can set up the cruise control function. After connecting buttons or switches for cruise control to the ports of the Controller or Onboard Computer, you need to configure the functions that relate to cruise control:\\+==== Speedometer setup ====
  
-**CRe** — cruise activation. \\ +The next block of settings in the menu section **Controller**  > **Extra parameters**  refers to the speed calculation settingIf you use an external speed sensor connected to the On-board computer, you need to configure it in menu **[[:en:display:start#data_sources_setup|Data source setup]]**.
-**CR+** — increase cruise speed (when active)\\ +
-**CR-** — decrease cruise speed (when active). \\ +
-**CRr** — restoring cruise (turning on the last saved speed)\\+
  
-For more information about configuring these functions, read the **[[en:controller:setup#i_o_port_configuration|I/O port configuration]]** section below. If the cruise control button is connected to the On-board computer, then you need to configure it in the **[[en:display:start#buttons_setup|Buttons setup]]** section\\+{{:en:controller:k26_en.png?nolink&  }}
  
-{{:en:controller:k9_en.png?nolink |}} +**Speed calculation**  — enabling speed calculation in the Controller. Useful for multi-motor configurations, you can turn off the speed calculation on some motors. Select of values **On**  and **Off**.
-In the **Cruise** menu item, you can select several control modes: \\ +
-**Disabled** — cruise control disabled. \\ +
-**Button** — activation of cruise control at the push of a button. The response time of the button is determined by the parameter **Cruise EN time**. \\ +
-**Switch** — activation of cruise control by turning on the switch, time is not used. \\ +
-**Throttle hold** — activation of cruise control by holding the throttle for a certain time in one position. The response time is determined by the parameter **Cruise EN time**. The accuracy is set by the parameter **Cruise by throttle** in percent (%). Select of values from **1%** to **30%**, in increment of **1%**. Accuracy is essential, as the throttle lever moves slightly during the ride due to shaking. The default is **2%**. \\ +
-**Allow Throttle hold** — similar to the previous mode, with the difference that to activate the cruise control, you must additionally press the cruise button\\+
  
-Next are the menu items for setting the cruise:+**Circumference**  — wheel circumference, in millimeters (mm). Select of values from **0mm**  to **3000mm**, in increments of **5mm**. To calculate the circumference, you can use [[https://www.omnicalculator.com/math/circumference|online calculator]].
  
-**Cruise restore** — this function activates the last saved cruise speed. To enableselect the **CRr** function when configuring **[[en:controller:setup#i_o_port_configuration|I/O ports]]**The function can be deactivated by selecting the parameter **Disabled**\\+**Motor sprocket**  — this setting specifies the number of sprocket teeth on the motor (notional)which allows you to set the gear ratio from motor shaft to the wheelAlso, this setting can be used as a reduction ratio for gear motors.
  
-**Cruise EN time** — setting the cruise activation delay in seconds after enabled button (**s**). Select of values from **0.25s** to **30.00s**, in increments **0.25s**. \\+**Wheel sprocket**  — the number of teeth of the wheel sprocket, similar to the setting **Motor sprocket**.
  
-**Cruise level** — selects what speed cruise will use: \\ +If you have a wheel motor, then in the section **Controller**  **Motor setup**  you need to specify the number of **Pole pair**  (divide the number of magnets by two). For gear motors or mid-drives, it is recommended to install an external speed sensor that connects to the Onboard computer or to any of the controller ports.
-  * **Throttle** — speed depends on the position of the throttle lever, turns on instantly. \\ +
-  * **Speed** — cruise enables when **Safe acceleration** reached after that uses current speed as a reference. \\ +
-  * **Mixed** — if controller cant use speed reference, uses throttle value\\+
  
-**Cruise smoothness** — this setting limits acceleration during cruising so that there are no jerks, measured in electrical revolutions per minute per second (ERPM/s). To get the value in rpm, the ERPM/s value must be divided by the number of pole pairs of the electric motor. Select of values from **0 ERPM/s** to **50000 ERPM/s**, in increments of **50 ERPM/s**. \\+==== Master-controller ====
  
-**# Used for cruise activation**\\ +{{:en:controller:k27_en.png?nolink&  }}In the menu section **Controller**  > **Extra parameters**  > **Master-controller**  you can enable the function of controlling other controllers from the current one. This setting is suitable for multi-motor configurations where control (throttlebrake and etc.) is connected into one of the controllers directly.
-**Safe acceleration** — limits the acceleration at which the cruise is activate, for example, to prevent it from engaging when accelerating, in electrical revolutions per minute per second (ERPM/s). Select value from **100 ERPM/s** to **10000 ERPM/s**, in increments of **100 ERPM/s**. \\ +
-**Min. speed** — speed below which you can not activate cruise or recovery, in kilometers per hour (km/h). Select of values from **3 km/h** to **127 km/h**in increments of **1 km/h**.\\+
  
-Additionally, to control the cruise, you can use the **CR+** and **CR-** functions for the buttons, which adjust the cruise speed when it is active. \\+~~CL~~
  
-What actions disable cruise control: +==== Other settings ====
-  * pressing the brake, analog or digital. +
-  * repeated throttle press. +
-  * if a switch is used — when it's disabled. +
-  * reverse enable.+
  
 +{{:en:controller:4_0.8.png?nolink&  }}**Limit t° CPU**  — limiting the temperature of the processor, in degrees Celsius (**°C**). When the specified threshold is reached, the phase current will be limited. Select of values from **60°C**  to **105°C**, in increments of **5°C**.
  
-==== Throttle and brake curves setup ====+**Device ID**  — setting the Controller number in the CAN network. This number is displayed in the menu section **Settings**  > **Devices**  in front of each device that is connected to the network using the [[:en:levcan|LEVCAN protocol]]. If, by default, your device number is **0**, we recommend changing it to another number for the correct firmware update.
  
-In the menu section **Controller** **Control** **Throttle/brake curves** you can set up the behavior of the throttle and brake levers. In **Throttle preset** and **Brake preset** menu items you can select one of the typical settingsselect one of the throttle or brake presets, and press enter, the preset will be loaded.+**Prefix 1**  and **Prefix 2**  — controller name setting for multi-motor configurations. Using the prefixes together or separately, you can specify where the electric motor that the Controller controls is located. The selectable values for each prefix are **None****Front****Rear**, **Left**, **Right**. To save the setting, go to the **Controller**  > **Save settings**  menu item and select **On**then restart the controller. The prefix will now appear in front of the controller name in the **Devices**  menu.
  
-{{:en:controller:k10_en.png?nolink |}}+For example, you have a 2WD scooter and two 12F controllers, you need to distinguish them somehow in the **Devices**  menu for easy setup. A controller for a front motor can be prefixed with **Front**, in which case the controller will be named **Front Nucular controller**  in the **Devices**  menu.
  
-You can select the following types of throttle and brake presets\\ +If you are using a 3WD drive or more, then both prefixes must be used for the controller name. For example, if the controller is driving a rear right motor, the setting will look like this: **Prefix 1**  — **Rear****Prefix 2**  — **Right**.
-**Linear** — smooth increase, direct dependence. \\ +
-**Exponential** — slow increase. \\ +
-**Normal** — average between linear and exponential. \\ +
-**Polynomial** — average between normal and exponential\\+
  
-Manual setting of throttle and brake position points is also available, to do this select **None** in **Throttle preset** or **Brake preset** and enter the value manually. There are eight position points available for throttle and brake:: \\ +===== PID regulators =====
-**Start** — starting point, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ +
-**1**-**6** — midpoints, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ +
-**End** — end point, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\+
  
-You can also manually edit the value of each point in the loaded preset. +In the **Controller**  > **PID regulators**  menu section, various signals of proportional-integral-derivative (PID) regulators are configured - devices in the control loop with feedback used in automatic control systems to generate a control signal in order to obtain the required accuracy and the quality of the transition process. **Settings for advanced users**.
-~~CL~~ \\ +
-==== Control source ====+
  
-The controller supports the connection of controls (throttle, brake, switches, and buttons) to the Controller, On-board computer, ulight board, or mixed connection when one part of the periphery is connected to the Controller, and the second part to the On-board computer, or to ulight and On-board computer. This is necessary in the case of Tork/PAS sensor configurations in the Controller + throttle lever in the On-board computer. In the menu item **Controller** **Control** **Control Source** you can set up the control source of the Controller`s\\+{{:en:controller:k28_en.png?nolink&  }}Two or three coefficients are used for the settings of each regulator: \\ **Ki**  — integral coefficient. \\ **Кp**  — proportional coefficient. \\ **Kd**  — differentiating coefficient.
  
-{{:en:controller:k11_en.png?nolink |}}+**Square Ki, Kp**  — phase current regulator for a square wave. \\ **FOC Ki, Kp**  — phase current regulator for FOC mode. \\ **FW Ki, Kp**  — field weakening coefficients. \\ **DCv Ki, Kp**  — voltage regulator on the DC bus. \\ **DCi Ki, Kp**  — current regulator on the DC bus. \\ **DCw Ki, Kp**  — power calculator. \\ **Speed Ki, Kp, Kd**  — speed regulator for throttle control modes **Speed**  and **Speed torque**. \\ **PLL Ki, Kp**  — speed regulator for motor angle interpolation. \\ **Acceleration Kp, Ki**  — deceleration and acceleration regulator.
  
-Select of control options: \\ +~~CL~~
-**Auto** — all sources will control the Сontroller. Built-in and external, connected via CAN bus (for example, On-board computer or ulight). \\ +
-**Embedd** — only what is connected directly to the Сontroller. \\ +
-**Remote** — control only via CAN bus (via On-board computer or Microlight). \\ +
-**Disabled** — disables any control of the Controller. +
-~~CL~~ \\+
  
-==== Throttle control mode setup ====+===== Status flags =====
  
-The menu item **Controller** > **Control** **Throttle mode** you can set up throttle lever mode.+The **Controller**  > **Status Flags**  menu section displays errors that may occur during the operation of the Controller. If an error occurs, the parameter value changes to **On**.
  
-{{:en:controller:6_0.8.png?nolink |}}+{{:en:controller:status_en_0504.png?nolink|}}
  
-Three throttle modes options are available:\\ +**Reset?**  — reset all statuses. Values **On**  and **Off**. \\ 
-**Speed** — a similar mode is used in Infineon controllers and non-programmable low-cost controllers and is characterized by the use of maximum current to reach a given speedIn this mode, the maximum thrust is used until the desired speed is reached, the thrust is not regulated by the throttle grip. \\ + **Max acceleration**  — maximum acceleration, in ERPM/s. \\ 
-**Torque** — in this mode, the throttle controls phase currentthe thrust is limited by the angle of rotation of the throttle. \\ + **Min deceleration**  — maximum deceleration, in ERPM/s. \\ 
-**Speed+torque** — combined mode (as Kelly), similar to the operation of the gas pedal in a car with an internal combustion engine. \\+ **Overload current**  — the last recorded current on the phases, in Amperes. \\ 
 + **Overload**  — exceeding the permissible current values. Values **On**  and **Off**. \\ 
 + **High V ripple** — overcurrent on the P24F controller (plate) which is monitored via voltage ripple. Values **On** and **Off**. \\ 
 + **Over-Field weakening**  — weakening error. Values **On**  and **Off**\\ 
 + **Supply overvoltage**  — too high supply voltage, the error will appear above 95V, but in general depends on the controller model. Values **On**  and **Off**. \\ 
 + **Supply undervoltage**  — too low supply voltageless than the minimum battery supply threshold. Values **On**  and **Off**. \\ 
 + **12V protection**  — error on the 12V power line. Values **On**  and **Off**. \\ 
 + **Control fail**  — the controller was not able to smoothly turn off the electric motor in time when the brake contacts were closed. Values **On**  and **Off**. **12V protection**  — breaking down or error on the 12V power line. Values **On**  and **Off**. \\ 
 + **Brake error**  — brake lever connection error. Values **On**  and **Off**. \\ 
 + **Throttle error**  — throttle lever connection error. Values **On**  and **Off**. \\ 
 + **Hall error**  — Hall sensor connection error. Values **On**  and **Off**. \\ 
 + **Code error**  — hall index errorhappens when motor not autodetected. Values **On**  and **Off**. \\ 
 + **Thread error**  — processor overload. Values **On**  and **Off**. The error is not critical, let us know if it occurs. \\ 
 + **PAS protection**  — PAS error. Values **On**  and **Off**. \\ 
 + **Controller overheat**  — overheat protection of the controller. Values **On**  and **Off**. \\ **Motor overheat**  — overheating protection of the electric motor. Values **On**  and **Off**. \\ 
 + **Protection fail**  — hardware error, malfunction of all protection systems during controller self-test. If this error occurs, the operation of the Controller will be impossible. Values **On**  and **Off**. \\ 
 + **ADC sample error**  — software error of the analog-to-digital converter (ADC). Values **On**  and **Off**. \\ 
 + **VBUS sample error**  — supply voltage measurement error. Values **On**  and **Off**. \\ 
 + **Voltage on phases**  — overvoltage on phases. Values **On**  and **Off**. \\ 
 + **LEC**  — types of errors on the CAN bus. If everything is alright you will see the value **Ok**. In case of errorsthere will be values - **Stuff**, **Form**, **Acknowledgment**, **Bit recessive**, **Bit dominant**, **CRC**, **SW**. Tell us the code if this error occurs. \\ 
 + **Receive w/error**  — CAN-bus errors on receiving. \\ 
 + **Sent w/error**  — CAN-bus errors on transmitting. \\ 
 + **CAN state**  — overloading buffers. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **OVR0**, **OVR1**, **OVR01**. Tell us the code if this error occurs. \\ 
 + **CAN RX**  — the number of messages in the CAN bus to receive. \\ 
 + **CAN TX**  — the number of messages in the CAN bus to transmission. \\ 
 + **CPU Load**  — current load of the central processor, in percentage (**%**).
  
-In the case of selecting the **Speed+torque** mode, pressing throttle to 50%, when achieved 50% speed, the current consumption will be reduced to hold speed. The acceleration current will also be proportionally lower. \\ +===== Debug information =====
-==== Throttle and brake voltage range setup ====+
  
-The menu items in the **Controller** > **Control** section allow you to set the voltage ranges of the throttle and brake grips\\+The menu section **Controller**  > **Debug information**  shows the main parameters of your Controller, electric motor, and the whole system - temperature, rpm, voltage, and current, as well as the values of the current regulators.
  
-{{:en:controller:7_0.8.png?nolink |}}+{{:en:controller:debug_0808.png?nolink&  }}
  
-Currentlyvoltage settings for all throttles and brakes are common. \\ +**Temp. controller**  — temperature of the Controllerin degrees Celsius (**°C**). \\ **Temp. motor**  — temperature of the electric motor, in degrees Celsius (**°C**). \\ **DC current**  — DC current, in amperes (**А**). \\ **DC voltage**  — DC voltage, in volts (**V**). \\ **AC current**  — AC current, in amperes (**А**). \\ **AC voltage**  — AC voltage, in volts (**V**). \\ **Motor U0**  — DC voltage on phases, in volts (**V**). \\ **System 12V**  — voltage on the CAN bus 12V, in volts (**V**). \\ **System 5V**  — voltage on the CAN bus 5V, in volts (**V**). \\ **RPM**  — motor speed, in RPM (**RPM**). \\ **ERPM**  — electric revolutions of the motor per minute (**ERPM**)\\ **Hall input**  — this parameter allows you to check the functionality of the Hall sensors. There are three digits in this item, each shows the signal level, if you rotate the motor slowly by handall three digits should change. If none of the digits change, check if the Hall connector is connected or the ground may be broken. If one of the digits does not change - there is no contact or the sensor wire is broken. To check the contacts in the controllerdisconnect the Hall connector and measure the voltages on the controller connector. There should be about 4V on the signal lines of the Halls5V on the power supply, and about 3V on the temperature sensor line. \\ **Hall index**  — virtual position of the motor, digits from 1 to 6 (normal operation). \\ **Throttle %**  — the percentage of how much the throttle is pressed. \\ **Brake %**  — the percentage of how much the brake is pressed. \\ **Speed request**  — set point for the speed regulator, in eRPM. \\ **Torque request**  — phase current request, either positive throttle or a negative brake. \\ **Torque limit**  — current limit for this type of controllertaking into account overheating. \\ **Temp CPU**  — CPU temperature, in degrees Celsius (**°C**).
-**# Throttle** — shows the voltage of throttle grip connected to the controller, in volts (V). \\ +
-**Throttle min** and **Throttle max** — range of the throttle grip, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. If the maximum value is exceeded by 5%protection against a broken throttle grip will be activated. If the range is incorrectly setthen when you fully press the throttle grip, the electric motor will turn off, in this caseyou need to increase the range value. \\+
  
-**# Brake** — shows the voltage of the brake connected to the controller, in volts (V). \\ +Next in the menu are the sections **Debug FOC**  and **Remote inputs**, which are described below.
-**Brake min** and **Brake max** — range of the analog brake leverin millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**\\+
  
-**Brake button power** — braking force when pressing the brake button relative to the phase braking level, in percent (%). This setting allows you to adjust the level of braking force with the brake levers with integrated brake buttons. \\ +==== Debug FOC ====
-**Invert brake** — inverts the voltage value from the built-in brake lever. Select **On** to enable. It is useful to enable when the voltage brake lever with reverse voltage is connected to the On-board computer and you want to use the value **Auto** in the menu item **Controller** > **Control** > **Control source**. The digital brake grip (i.e. button) connects to the On-board computer, see section **[[en:display:start#buttons_setup|Buttons setup]]**. \\ +
-**Active braking** — enables brake to use the battery for stopping. Select of values **On** and **Off**. \\ +
-**Brake at overheat** — enables full torque braking when motor overheated. Select of values **On** and **Off**. \\ +
-**Reverse on brake** — after stopping, pressing the brake lever again activates reverse. Select of values **On** and **Off**. +
-==== Setup 100% speed value ====+
  
-The menu items in the **Controller** > **Control** section allow you to adjust the 100% speed level. The maximum speed in the field weakening mode is 150%.+In the menu section **Controller**  > **Debug information**  > **Debug FOC**
  
-{{:en:controller:k14_en.png?nolink |}}+{{:en:controller:k31_en.png?nolink&  }}
  
-**Speed ref. filter** — filter mode selectionSelect of values **OFF**, **Linear****Quadratic**, **Cubic**. For the control modes **Speed** and **Speed+torque**, a speed reference filter is applied, for a smoother response to the throttle changeThe filter algorithm calculates the difference between the previous speed request and the current one, multiplies the error by a power of 1,2,(linear, quadratic, and cubic, respectively), and multiplies by a factorThe resulting value is used as the cutoff frequency of the low-pass filter. The larger the changethe sharper the response to it\\+**U Q**  — Q-axis voltage, in volts (**V**)\\ **U D**  — D-axis voltagein volts (**V**). \\ **I Q**  — Q-axis currentin amperes (**А**)\\ **I D**  — D-axis current, in amperes (**А**)\\ **Ireqest Q**  — Q-axis current requestin amperes (**А**). \\ **Ireqest D**  — D-axis current requestin amperes (**А**).
  
-**Filter factor** — sets the filtration factor. Select of values from **0** to **30000**, in increments of **100**. \\+~~CL~~
  
-**Speed mode** allows you to select the level of 100% speed and what it depends on: \\ +==== Remote inputs ====
-  * **OFF** — completely disables speed control PID. \\ +
-  * **Middle U bat** — the average value between the minimum and maximum voltage of the battery settings used as speed reference, depending on motor kV. \\ +
-  * **U supply** — supply voltage used as speed reference, depending on motor kV. \\ +
-  * **Ref. speed** — speed in km/h, is set by parameter **Reference speed**. The speed value is taken from the motor or from an external speed sensor connected to the controller. \\ +
-  * **Ref. ERPM** — speed in motor electric RPM, is set by parameter **Reference speed**. \\+
  
-**Minimum speed** —  in electrical revolutions per minute (ERPM). Select of values from **0 ERPM** to **100000 ERPM**, in increments of **100 ERPM**.+In the menu section **Controller**  **Debug information**  > **Remote inputs**  you can view the parameters of the throttle and brake levers connected to other devices connected to the CAN-bus (On-board computer or uLight).
  
-**Speed lim. at 0% throttle** — enables limiting the speed when the throttle grip is completely releasedSelect of values **On** and **Оff**. Selecting **Off** disables motor control when the throttle is released.+{{:en:controller:k32_en.png?nolink&  }}**Throttle**  — voltage on the throttle lever at a remote source (On-board computer or uLight), in volts (**V**)\\ **Brake**  — voltage at the brake lever at a remote source (On-board computer or uLight), in volts (**V**)\\ **Throttle % **— the percentage of how much the throttle pressed at a remote source. \\ **Brake %**  — the percentage of how much the brake pressed at a remote source.
  
-===== Motor setup =====+~~CL~~
  
-The **Controller** > **Motor Setup** menu contains all settings related to electric motor operation parameters.+===== Logger =====
  
-==== Motor temperature sensor ====+In the **Controller **  > **Logger**  menu section, you can enable and configure the data logging during the operation of the Controller. This functionality is experimental, errors may occur. The file is saved in ** CSV **  format to an SD card inserted into the On-board computer. To view the file, you can use the service [[https://datazap.me/|Datazap]]. The SD card must have a FAT32 file system.
  
-In the menu section **Controller** > **Motor setup** > **Motor t°-sensor** you can select a temperature range in which a smooth power limit will occur (**Delta °t** parameter) and specify the maximum temperature (**°t max**).+{{:en:controller:11_0.8.png?nolink&  }}
  
-{{:en:controller:2_0.8.png?nolink |}}+**Start logging**  — to start recording, select **On**  and press the right button of the On-board computerAfter that, the **#State**  menu item will change to **Waiting**  status. The recording will start automatically after pressing the throttle grip. If an error occurs during the recording process, you will see its code in the ** # Error code **  menu item. In case of an error, firstly, check that the SD card has the FAT32 file system, and secondly, that there is free space on the SD card for recording. Additionally, you can delete unnecessary files from the card. After that, restart the Controller and start recording again. If the error repeats, contact us through the website or chat technical support and report the error code.
  
-**°t max** — maximum electric motor temperaturein degrees Celsius (°C). Select of values from **50°C** to **200°C**, in increments of **1°C**. \\ +**Stop logging**  — stop recordingselect **On**  to end recording.
-**Delta °t**  — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning of the power limit, in degrees Celsius (°C). Select of values from **1°C** to **100°C**, in increments of **1 °C**\\+
  
-In the menu item **Sensor type** you can select the following types of temperature sensors that support the controller — **KTY81(82)**, **KTY83**, **KTY84**, **NTC10K (B:3950)**, **NTC10K (B:3380)**, **PT1000**. To disconnect the temperature control, select the value **OFF**.+~~CL~~
  
-It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors and select the one that displays data the most closely to room temperature. The current measured temperature is displayed at **# Value °t #**. \\+ \\ **Start mode**  — selection of recording start mode:
  
-The **# °t R (+-10%)#** menu item displays the resistance of the motor temperature sensor, with an accuracy of +/-10%.+  * **Manual**  — enable manual recording. 
 +  * **At start**  — recording starts automatically when the Controller is turned on. 
 +**Log time**  — two parameters of time for recording to choose from:
  
-==== Clutch ====+  * **Time step**  — delta of time since the previous record. 
 +  * **Sys time**  — global time, which is incremented after the start of the controller. 
 +**Log rate**  — delay between records of values. You can choose either the number of PWM cycles (**PWM1**, **PWM2**, **PWM5**, **PWM10**), either time (**1ms**, **10ms**, **20ms**, **100ms**, **1s**, **5s**, **10s**, **30s**).
  
-In the menu section **Controller** > **Motor Setup** > **Clutch** you can configure a smooth engine launch for soft engagement clutch or freewheel. Useful for gear motors or mid-drives. At the moment, the setting works well only in the control mode **Torque**, because the clutch there is always engaged. An alternative option is to configure the acceleration limit in the modes **S1**, **S2**, **S3** in the menu section **Controller** > **Advanced modes**.+**Mode**  — recording mode selection:
  
-{{:en:controller:k16_en.png?nolink |}}+  * **Buffered**  — buffering and recording in segments. 
 +  * **Max rate**  — continuous recording mode. 
 +**Data averaging**  — using filters while recording: 
 + 
 +  * **None**  — filter disabled (records real values). 
 +  * **Fast**  — slight averaging (smoothes values). 
 +  * **Slow**  — large averaging. 
 +**Add header to log**  — adding the name of the controller when writing the log, so that you can understand which controller the log belongs to in multi-motors configurations. You can set the name of the controller in the menu **Controller**  > **Extra parameters**, items **Prefix 1**  and **Prefix 2**. 
 + 
 +Next, in the **# Data to log**  menu sections, you can select the set of parameters you want to record. Select **On**  to enable parameter recording. 
 + 
 +{{:en:controller:k_55_en.png?nolink&  }}**# Data to log**: \\ **Battery Voltage**  — battery voltage data logging. \\ **Battery Current**  — battery current data logging. \\ **Motor Voltage**  — motor voltage data logging. \\ **Motor Current**  — motor current data logging. \\ **Wheel speed**  — wheel speed data logging. \\ **Motor rad/s**  — data logging of the angular speed of the electric motor. \\ **Motor RPM**  — data logging of revolutions of an electric motor per minute. \\ **Tmotor °C**  — data logging of the electric motor temperature. \\ **Tfet °C**  — data logging the temperature of field-effect transistors. \\ **Raw hall input**  — data logging the input status from Hall sensors without filter. \\ **Hall index**  — virtual position of motor. \\ **Throttle %**  — throttle grip data logging. \\ **Brake %**  — brake lever data logging. \\ **FOC Vq**  — Q-axis voltage data logging. \\ **FOC Vd**  — D-axis voltage data logging. \\ **FOC Iq**  — Q-axis current data logging. \\ **FOC Id**  — D-axis current data logging. \\ **FOC Iq request**  — Q-axis current request data logging. \\ **FOC Id request**  — D-axis current request data logging. \\ **Current phA**  — data logging the current on the A phase of the electric motor. \\ **Current phB**  — data logging the current on the B phase of the electric motor. \\ **Current phC**  — data logging the current on the С phase of the electric motor. \\ **PAS frequency RPM**  — PAS frequency data logging. \\ **PAS torque Nm**  — PAS torque data logging. \\ **PAS power W**  — PAS power data logging. \\ **Speed request**  — speed request data logging. \\ **Torque request**  — torque request data logging. 
 + 
 +===== Statistics =====
  
-The parameter **Mode** determines the way of operation:: \\ +In the menu section **Controller**  > **Statistics**  you can view the data on the ControllerThese are trip statistics that will be automatically reset when the controller is powered off. If you have several Controllers in the systemthen you can see the summary data for all controllers in the general statistics in the On-board computer.
-**Accelerate** — smoothly accelerates the motor until the load appears\\ +
-**Accelerate and hold** — in addition to the previous oneit applies weak torque to the motor after the throttle is released, this mode allows you to switch speeds at mid-drive systems without using the pedals\\+
  
-**# Phase amps** \\  +{{:en:controller:statistics_0808.png?nolink&  }}
-**Start time** — maximum time for soft start, in seconds (s)Select values from **1s** to **20s**, in increments of **1s**. \\ +
-**Start current** — phase motor current at which the load will be detected and the soft start is disabled, in amperes (А). Select values from **0.2А** to **50.0А**, in increments of **0.2А**. This value must be higher than the phase current for specified acceleration of the motor without load. \\ +
-**Detection time** — the time during which the load must be present, after which the soft start will be switched off, in milliseconds (ms). Select values from **10 ms** to **1000 ms**, in increments of **10 ms**. \\ +
-**Acceleration** —  value in volts/seconds (V/s). Select values from **2V/s** to **1000V/s**, in increments of **2 V/s**. The higher the value, the more you need to specify **Start current**, since the motor will consume more current during acceleration. \\ +
-**Hold (20%)** and **Hold (80%)** — two parameters regulating the phase current supplied to the motor in the mode **Accelerate and hold**, in amperes (А). **20%** — current at low speeds, **80%** — current at about maximum speed. It is possible to determine the approximate values ​​by the no-load current of the motor. Select values from **0.2А** to **50.0А**, in increments of **0.2А**. \\ +
-**Hold enable time** — time through which after the throttle has been pressed, torque hold will become available, in seconds (s). Select values from **1s** to **120s**, in increments of **4s**. \\+
  
-**Hold time** — the time during which torque will be applied after releasing the throttle, in seconds (s). Select values from **1s** to **120 s**, in increments of **1s**. \\+**Wh used total**  — total energy consumption (used plus regen), in Watt-hours (**Wh**). \\ **Wh used**  — energy consumption, in Watt-hours (**Wh**). \\ **Wh regen.**  — energy gained during the recuperation process, in Watt-hours (**Wh**). \\ **Regen. %**  — the percentage of energy recovered during recuperation (**%**). \\ **Ah used total**  — total energy consumption (used plus regen), in Ampere hours (**Ah**). \\ **Ah used**  — energy consumption, in Ampere hours (**Ah**). \\ **Ah regen.**  — energy gained during the recuperation process, in Ampere hours (**Ah**). \\ **Min bat. voltage**  — minimum battery voltage, in Volts (**V**). \\ **Max phase curr.**  — maximum phase current, in Amps (**A**). \\ **Peak power**  — maximum motor power, in Watts (**W**). \\ **Max motor temp.**  — maximum motor temperature, in degrees Celsius (**°C**). \\ **Max controller temp.**  — the maximum temperature of the Controller, in degrees Celsius (**°C**). 
 + 
 +The values below are approximate! \\ **Motor efficiency**  — efficiency of the electric motor, in percent (**%**). \\ **Eff. average**  — average efficiency of the electric motor, in percent (**%**). \\ **Torque**  — current torque of the electric motor, in Newton-meters (**Nm**). \\ **Power out**  — the power that the electric motor delivers, in Watts (**W**). \\ **Power in**  — power supplied to the electric motor, in Watts (**W**). 
 + 
 +===== Device information ===== 
 + 
 +In the menu section **Controller**  > **Device Information**  you can view the basic information about the Controller. In this menu, you can check which firmware version is loaded into your Controller, as well as other parameters that differ depending on the Controller model. 
 + 
 +{{:en:controller:device_info.png?nolink&  }} 
 + 
 +**Nucular Controller**  — device name depending on the type of Controller. \\ **Max supply**  — 95V. The warranty covers supply voltages up to **90V**  inclusive. \\ **Max current**  — the value of the maximum phase current, depending on the type of Controller, in amperes (A). \\ **Encoder speed**  — 26kHz or 580kHz (new Controller version with orange phase wires). \\ **Firmware date**  — firmware compilation date. \\ **Firmware ver.**  — version of the installed firmware, you can check for updates in the section **[[:en:firmware|Firmware]]**. \\ **Loader date**  — the data loader compilation date. \\ **Loader version**  — data loader version. \\ **Production date**  — date of manufacture of the controller. \\ **Worked**  — operating time of the Controller in kilowatt-hours (kW*h). \\ **t° middle 100 h**  — the average temperature of the Сontroller over the last 100 hours. \\ **t° middle**  — the average temperature of the Сontroller over all time. \\ **Current protections**  — the number of triggered overcurrent protections over all time of operation of the controller. \\ **Temperature protections**  — the number of triggered temperature protections over all time of operation of the controller. \\ **Voltage protections**  — the number of triggered voltage protections over all time of operation of the controller. \\ **Power cycle**  — number of controller switching on. \\ **Power-on time**  — total operating time of the Controller, minutes, hours, days. \\ **Serial number**  — serial number of the Controller (for devices manufactured from 01 Jul 2022). Take a photo or write down this number and keep it separate from the Controller. You may need it when requesting repairs or if the Controller is stolen. After updating the firmware to 0.8.7, in some versions of controllers manufactured before 01 Jul 2022, a serial number may also appear. Check after update.
  
-<WRAP center round tip 60%>\\ Optimal settings for MAC motor: **Accelerate**, 15a, 50V/s, 200ms.</WRAP> 
  
 ==== Hall sensors setup ==== ==== Hall sensors setup ====
  
-Under the menu section **Controller** > **Motor setup** > **Position sensors**, you can find the menu items for configuring the Hall sensors of the electric motor.+Further in the menu section **Controller**  > **Motor Setup**  > **Position sensor** > **Hall settings** there are items for additional setting of Hall sensors.
  
-=== Manual setup the Hall sensors angles ===+{{:en:controller:hall_setup_0908.png?nolink& |}}
  
-In general, it is not recommended to change these settings manually!\\ +**Hall filter**  — enable or disable the filter in the direction of rotation, select the **Direction**  and **OFF**  values.
-In the menu section **Controller** **Motor settings** **Manual angle setup** you can set up the Hall sensors angles of the electric motor\\+
  
-{{:en:controller:k17_en.png?nolink |}}+**State filter**  — select the delay time, in seconds (sec). Selection of values from **0.000s**  to **1.000s**, in increments of **0.002s**. This delay is used if the wrong value of the Hall sensors is received. All indicators that are less than the set value will be filtered out.
  
-**Offset for square** — additional shift for square wave mode, in degrees (**°**). Select of values from **-30°** to **30°**, in increments of **1°**. \\ +**Direction filter**  — select the delay time for changing the direction of rotation of the electric motor (forward/backward), in seconds (sec). Selection of values from **0.000s**  to **1.000s**, in increments of **0.002s**.
-**Offset total fwd** — shift all Halls sensors by the specified value for the direct rotation of the motor, in degrees (**°**). Select of values from **-60°** to **60°**, in increments of **1°**. \\ +
-**Offset total bkwd** — shift all Halls sensors by the specified value for the reverse rotation of the motor., in degrees (**°**). Select of values from **-60°** to **60°**, in increments of ****. \\+
  
-To shift all the halls, you must press the right button of the On-board computer, enter the shift angle, press the right button again. The value will be reset and the angle of all halls will change to the specified valueYou can change the angle of the hall shift in the opposite direction by setting a negative value\\+The next menu sections shows the Hall indices and Hall angles for the two directions of rotation of the electric motorThese indices are used for the internal operation of the Controller.
  
-**Reset angles** — reset of all Hall sensors angles. Select of values **On** and **Off**. \\ +~~CL~~
-**Integration threshold** — analogue of Hall angles for sensorless engine control mode, in volts (**V**). \\ +
-**Hall adjust Ki** — the meaning of the coefficient is to find the midpoint of the position of the Hall sensors when adjusting them. Values from **0.02** to **5.00**, in increments of **0.02**. If the value of the coefficient is too small, then the tuning process will end before the midpoint is determined. If the value of the coefficient is too large, then the setting will not be completed and will stop by timeout, because the midpoint will not be found due to the angles changing too often.+
  
-=== Hall table ===+==== Manual setup the Hall sensors angles ====
  
-The **Controller** > **Motor Setup** > **Hall table** menu section shows the Hall indices and Hall angles for the two directions of rotation of the electric motor. These indices are used for the internal operation of the Controller. \\ +In general, it is not recommended to change these settings manually! \\ In the menu section **Controller**  > **Motor settings**  > **Manual angle setup**  you can set up the Hall sensors angles of the electric motor.
  
-{{:en:controller:k18_en.png?nolink |}} +{{:en:controller:k17_en.png?nolink&  }}
-~~CL~~ \\+
  
-=== Advanced Hall sensor settings ===+**Offset for square**  — additional shift for square wave mode, in degrees (**°**). Select of values from **-30°**  to **30°**, in increments of **1°**. \\ **Offset total fwd**  — shift all Halls sensors by the specified value for the direct rotation of the motor, in degrees (**°**). Select of values from **-60°**  to **60°**, in increments of **1°**. \\ **Offset total bkwd**  — shift all Halls sensors by the specified value for the reverse rotation of the motor., in degrees (**°**). Select of values from **-60°**  to **60°**, in increments of **1°**.
  
-Further in the menu section **Controller** > **Motor Setup** > **Position sensor** there are items for additional setting of Hall sensors.+To shift all the halls, you must press the right button of the On-board computer, enter the shift angle, press the right button again. The value will be reset and the angle of all halls will change to the specified value. You can change the angle of the hall shift in the opposite direction by setting a negative value.
  
-{{:en:controller:3_0.8.png?nolink |}}+**Reset angles**  — reset of all Hall sensors anglesSelect of values **On**  and **Off**. \\ **Integration threshold**  — analogue of Hall angles for sensorless engine control mode, in volts (**V**). \\ **Hall adjust Ki**  — the meaning of the coefficient is to find the midpoint of the position of the Hall sensors when adjusting them. Values from **0.02**  to **5.00**, in increments of **0.02**. If the value of the coefficient is too small, then the tuning process will end before the midpoint is determined. If the value of the coefficient is too large, then the setting will not be completed and will stop by timeout, because the midpoint will not be found due to the angles changing too often.
  
-**Sensor type** — currently, by default, only one type of **Hall** sensor is available. Additional types of supported sensors will be added in future updates. 
  
-**Sensor mode** — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes: \\ +==== Encoder setup ====
-**Sensorless** — motor control using BEMF integration, parameter **Integration threshold** is used. It is rather insensitive to tuning, but more accurate tuning may be required for high-speed motors (such as RC). At the moment, the sensorless does not have a start-up algorithm, it works stably only at some speed. Hall setups start with sensorless mode.\\ +
-**Combined** — start the motor on Hall sensors, then switch to sensorless mode, the threshold is determined by the parameter radians per second (**rad/s**) in the **From hall to s-less** menu item. Select of values from **0.00 rad/s** to **2.00 rad/s** in increments of **0.05 rad/s**. To convert values keep in mind that 1 rad/s to RPM 9.5493 RPM. \\ +
-**Sensors** — electric motor control only by signals from Hall sensors. \\ +
-**Freq** — frequency control. Do not use this mode for driving! \\+
  
-**Interpolate halls** — smooth change of the Hall sensors angle based on speed. Used for FOC modeSelect of values **On** and **Off**. \\+In the menu **Controller** > **Motor Setup** > **Position sensor** > **Encoder settings** there are menu items for configuring the motor encoder. The parameter values in each of the items will appear after passing through the Auto-setup procedureControllers with encoder capable have orange phase wires and an encoder speed of 580kHZ under **Controller** **Device Information**. The wire for connecting the electric motor with the encoder is ordered separately and is installed instead of the wire with connector for the Hall sensors. \\
  
-**Interpolation start** — the motor is always started from discrete angleif digital halls are used. After the specified speed, the angle starts to change smoothlySelect of values from **0 rad/s** to **100 rad/s**, in increments of **1 rad/s**. \\+Wiring and connectors Compatibility: \\ 
 +**Halls** > **Encoder** — if your controller has connector for Hall sensorsthen you can make an adapter for the encoder yourself. Butin this case, you will not be able to move when you turn it on, you will need to push the electric bike with your feet to start\\ 
 +**Encoder** > **Halls** — if your controller has an encoder connector, then you can make an adapter for Hall sensors yourself. Everything will work. \\ 
 + 
 +{{:en:controller:encoder.png?nolink& |}} 
 + 
 +**Steps** — number of encoder steps, selectable in increments of **1**.\\ 
 +**# Invert counter** — select of values **Off** and **On**.\\ 
 +**# Invert PWM** — select of values **Off** and **On**.\\ 
 +**# Index Z** — the value of the additional output signal of the encoder (zero pointer), the choice of values from **0** to **7**, in increments of **1**.\\ 
 +**# Shift Z FW** — signal shift, select of values from **-60°** to **+60°** in increments of **1°**.\\ 
 +**# Shift Z BW** — signal shift, select of values from **-60°** to **+60°** in increments of **1°**.\\ 
 + 
 +== Debug information == 
 +**Index** — encoder index signal value. \\ 
 +**Z-Index** — the value of the zero pointer.\\ 
 +**PWM Period** — PWM signal period, in microseconds (**µs**).\\ 
 +**PWM Width** — PWM signal pulse width, in microseconds (**µs**).\\ 
 +**Rad by index** — position of the electric motor by index, in radians (**rad**).\\ 
 +**Rad by PWM** — position of the electric motor by PWM, in radians (**rad**).\\
  
-**Frequency control** — a separate mode that can be used to power equipment through a transformer or to dry the varnish on the motor windings. Select of values from **10 HZ** to **200 HZ**, in increments of **1 HZ**. \\ 
  
-**Hall filter** — enable or disable the filter in the direction of rotation, select the **Direction** and **OFF** values.\\ 
  
-**State filter** — select the delay time, in seconds (sec). Selection of values from **0.000s** to **1.000s**, in increments of **0.002s**. This delay is used if the wrong value of the Hall sensors is received. All indicators that are less than the set value will be filtered out. \\  
  
-**Direction filter** — select the delay time for changing the direction of rotation of the electric motor (forward/backward), in seconds (sec). Selection of values from **0.000s** to **1.000s**, in increments of **0.002s**. 
  
 ==== Motor parameters ==== ==== Motor parameters ====
  
-Items in the **Controller** > **Motor setup** menu section allow you to configure the parameters of the electric motor.+Items in the **Controller**  > **Motor setup**  menu section allow you to configure the parameters of the electric motor.
  
-{{:en:controller:8_0.8.png?nolink |}}+{{:en:controller:mtpa.png?nolink|}}
  
-**Pole pair** — the number of pole pairs of the stator winding of the electric motor determines the speed at which the motor shaft will rotate. This parameter is used to calculate RPM and speed. For a more accurate autodetection of the Hall sensors angles, you must specify the correct value for the number of pole pairs for your motor. For the most popular motors, you can see this value in the table **[[en:motor_information|Motor Information]]**. If your motor is not listed in the table, check with the manufacturer for the number of pole pairs. \\+**Pole pair**  — the number of pole pairs of the stator winding of the electric motor determines the speed at which the motor shaft will rotate. This parameter is used to calculate RPM and speed. For a more accurate autodetection of the Hall sensors angles, you must specify the correct value for the number of pole pairs for your motor. For the most popular motors, you can see this value in the table **[[:en:motor_information|Motor Information]]**. If your motor is not listed in the table, check with the manufacturer for the number of pole pairs.
  
-**Spin direction** — this setting allows you to change the direction of rotation of the electric motor. Select of values **Forward** and **Invert**. Or you can swap two motor phases to change the direction of rotation.\\+**Spin direction**  — this setting allows you to change the direction of rotation of the electric motor. Select of values **Forward**  and **Invert**. Or you can swap two motor phases to change the direction of rotation.
  
-**Integration thr.** — the analog of Hall sensors angles for sensorless motor control mode, in volts (**V**). \\+**Integration thr.**  — the analog of Hall sensors angles for sensorless motor control mode, in volts (**V**).
  
-**Control mode** — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes: \\ +**Control mode**  — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes: \\ **Off**  — control mode is disabled. \\ **Square**  — outdated control method used only for motor detection. \\ **FOC**  — field-oriented control of the motor. \\ **DC-DC**  — charging mode when you use the controller in motor charging mode.
-**Off** — control mode is disabled.\\ +
-**Square** — outdated control method used only for motor detection. \\ +
-**FOC** — field-oriented control of the motor. \\ +
-**DC-DC** — charging mode when you use the controller in motor charging mode. \\+
  
-The control mode selected in this menu is the priority setting for the controller. If the Hall sensor mode is selected in the **Controller** > **Motor setup** > **Position sensor** menu, which does not correspond to the set operating mode of the electric motor, then this Hall sensor mode will be automatically replaced with a more suitable one.+The control mode selected in this menu is the priority setting for the controller. If the Hall sensor mode is selected in the **Controller**  > **Motor setup**  > **Position sensor**  menu, which does not correspond to the set operating mode of the electric motor, then this Hall sensor mode will be automatically replaced with a more suitable one.
  
-**Max motor U** — limits voltage supplied to the motor, in volts (**V**). In most cases, this parameter is not needed. Select of values from **0V** to **100V**, in increments of **1V**. \\+**Max motor U**  — limits voltage supplied to the motor, in volts (**V**). In most cases, this parameter is not needed. Select of values from **0V**  to **100V**, in increments of **1V**.
  
-**kV** — motor parameter, electric revolutions per volt (**eRPM/V**). \\+**kV**  — motor parameter, electric revolutions per volt (**eRPM/V**).
  
-Next are the menu items for configuring the MTPA, this function allows you to introduce a negative id current to increase the torque on the IPM motors. +Next are the menu items for configuring the MTPA, this function allows you to introduce a negative id current to increase the torque on the IPM motors.
  
-**Phase resistance** — the result of measuring the phase resistance of the electric motor during auto-setup (menu item **Motor LR**), in Ohms (Ohm). \\+**Phase resistance**  — the result of measuring the phase resistance of the electric motor during auto-setup (menu item **Motor LR**), in Ohms (Ohm).
  
-**Inductance d** — the result of measuring the inductance of the electric motor along the d axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The d-axis ("straight") refers to the component of the stator magnetic field that is in phase with the rotor magnetic field. \\+**Inductance d**  — the result of measuring the inductance of the electric motor along the d axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The d-axis ("straight") refers to the component of the stator magnetic field that is in phase with the rotor magnetic field.
  
-**Inductance q** — the result of measuring the inductance of the electric motor along the q axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The q-axis ("quadrature") refers to the component of the stator magnetic field that is 90 ° out of phase with the rotor magnetic field. \\+**Inductance q**  — the result of measuring the inductance of the electric motor along the q axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The q-axis ("quadrature") refers to the component of the stator magnetic field that is 90 ° out of phase with the rotor magnetic field.
  
-**Flux linkage** — is the total magnetic flux permeating the electrical circuit, in Weber (Wb). \\+**Flux linkage**  — is the total magnetic flux permeating the electrical circuit, in Weber (Wb).
  
-**# Square wave settings:** \\ +**MTPA (IPM Motor)** — enable (**On**) the MTPA function for IPM motorfor all other motors this function must be disabled (**Off**). 
-**Square offset** — additional shift for square wave mode, in degrees (°). Select of values from -30° to 30°, in increments of 1°. This item is similar to the same item in the menu **Controller** > **Motor setup** > **Position sensor** > **Manual angle setup**. \\ +
-**Boost square current** — in the sensorless or square mode, applies 100% PWM at the beginning of each winding switch. Starting from specified speed and minimum requested current. Select of values **On** and **Off**. \\ +
-**Boost current** — setting refers to the control mode **Square**, the minimum current from which the rapid current pumping in the windings is turned on, in amperes (**А**). Select of values from **0A** to **100A**, in increments of **1A**. \\ +
-**Boost speed** — setting refers to the control mode **Square**the minimum speed after which the rapid pumping of current in the windings is turned on, in radians per second (**rad/s**). Select of values from **0.00rad/s** to **2.00rad/ms** in increments of **0.05rad/s**. \\+
  
 +**# Square wave settings:** \\ **Square offset**  — additional shift for square wave mode, in degrees (°). Select of values from -30° to 30°, in increments of 1°. This item is similar to the same item in the menu **Controller**  > **Motor setup**  > **Position sensor**  > **Manual angle setup**. \\ **Boost square current**  — in the sensorless or square mode, applies 100% PWM at the beginning of each winding switch. Starting from specified speed and minimum requested current. Select of values **On**  and **Off**. \\ **Boost current**  — setting refers to the control mode **Square**, the minimum current from which the rapid current pumping in the windings is turned on, in amperes (**А**). Select of values from **0A**  to **100A**, in increments of **1A**. \\ **Boost speed**  — setting refers to the control mode **Square**, the minimum speed after which the rapid pumping of current in the windings is turned on, in radians per second (**rad/s**). Select of values from **0.00rad/s**  to **2.00rad/ms**  in increments of **0.05rad/s**.
  
 ===== Battery ===== ===== Battery =====
  
-In the **Controller** > **Battery** menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V** to **90V**, this is **21S** for Lithium-ion (Li-ion) batteries and **25S** for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[en:display:start#battery_capacity|settings]] of On-board Computer.+In the **Controller** > **Battery** menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V** to **90V**, this is **21S** for Lithium-ion (Li-ion) batteries and **25S** for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[:en:display:start#battery_capacity|settings]] of On-board Computer. If you use several batteries with different parameters on the same bike, you can save the configurations for each battery on the SD card and load them after replacing the battery. The SD card can be stored in the On-board computer.
  
-{{:en:controller:k20_en.png?nolink |}}+{{:en:controller:k20_en.png?nolink&  }}
  
-**Full charge** — delta voltage relative to the maximum, at which when the controller is turned on, will reset the watt-hour consumption, in volts (**dV**). This setting resets the **From charge statistics** when the Controller is turned on. Select values from **0.00 dV** to **10.00 dV**, in increments of **0.3 dV**.  \\+**Full charge** — delta voltage relative to the maximum, at which when the controller is turned on, will reset the watt-hour consumption, in volts (**dV**). This setting resets the **From charge statistics** when the Controller is turned on. Select values from **0.00 dV** to **10.00 dV**, in increments of **0.3 dV**.
  
-**Supply max** and **Supply min** — battery voltage range, in volts (**V**). Select values from **20.00V** to **95.00V**, in increments of **00.1V**. Also, these settings are used for the **Converter** mode. \\+**Supply max** and **Supply min** — battery voltage range, in volts (**V**). Select values from **20.00V** to **95.00V**, in increments of **0.1V**. Also, these settings are used for the **Converter** mode.
  
-For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**. \\ +For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**.\\
 For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**. \\ For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**. \\
  
-<WRAP center round important 60%> +<WRAP center round important 60%> We guarantee stable operation of the Controller at voltages up to **90V** inclusive. Using a battery over 90V may damage the Controller and void the warranty. </WRAP> \\
-We guarantee stable operation of the Controller at voltages up to **90V** inclusive. Using a battery over 90V may damage the Controller and void the warranty. +
-</WRAP>\\ +
  
-**Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.  \\+**Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.
  
-**Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.  \\+**Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.
  
-**Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** to **30000 W**, in increments of **100W**.  \\+**Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** to **30000 W**, in increments of **100W**.
  
 **# DC voltage** — current supply voltage of the Controller, in volts (**V**). **# DC voltage** — current supply voltage of the Controller, in volts (**V**).
 +
  
 ===== Converter ===== ===== Converter =====
  
-In the menu section **Controller** > **Converter**, can configure charging mode from the power supply through the motor. Charging through the inductor is not currently supported. For the power supply connection diagram, see this [[hhttps://drive.google.com/file/d/1KkEgWcJ5U-AEkk6GrXhDNlYXFCcsjpUQ/view|link]].+In the menu section **Controller**  > **Converter**, can configure charging mode from the power supply through the motor. Charging through the inductor is not currently supported. For the power supply connection diagram, see this [[en:controller:setup#connection_diagram|link]].
  
-{{:en:controller:k21_en.png?nolink |}}+{{:en:controller:k21_en.png?nolink&  }}
  
-**Enable** — turn on the converter mode and start charging. Select of values **On** and **Off**. \\+**Enable**  — turn on the converter mode and start charging. Select of values **On**  and **Off**.
  
-**Auto-enable** — allows the automatic start of charging when the charging PSU is connected to the controller. Select of values **On** and **Off**. \\+**Auto-enable**  — allows the automatic start of charging when the charging PSU is connected to the controller. Select of values **On**  and **Off**.
  
-**Detection threshold** — minimum voltage on phases when charger mode activates, also disables motor control, in volts per phase (**Vph**). Select of values from **10Vph** to **80Vph**, in increments of **1Vph**. \\+**Detection threshold**  — minimum voltage on phases when charger mode activates, also disables motor control, in volts per phase (**Vph**). Select of values from **10Vph**  to **80Vph**, in increments of **1Vph**.
  
-**Battery max I** — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А** to **100.0A**, in increments of **0.5А**. \\+**Battery max I**  — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А**  to **100.0A**, in increments of **0.5А**.
  
-**Battery min I** — minimum charge current when current is decreased by voltage, in amperes (**А**). Select of values from **0.5А** to **10.0A**, in increments of **0.5А**. \\+**Battery min I**  — minimum charge current when current is decreased by voltage, in amperes (**А**). Select of values from **0.5А**  to **10.0A**, in increments of **0.5А**.
  
-**Undercharge** — voltage relative to maximum battery voltage setup, in volts (**V**). Let's decrease the full charge voltage. Select of values from **0.00V** to **10.0V**, in increments of **0.1V**. \\+**Undercharge**  — voltage relative to maximum battery voltage setup, in volts (**V**). Let's decrease the full charge voltage. Select of values from **0.00V**  to **10.0V**, in increments of **0.1V**.
  
-**Current drop delta** — decreases charging current down to **Battery min I** as the battery reaches maximum voltage on specified voltage range, in volts (**dV**). Select of values from **0.0dV** to **20.0 dV** in increments of **0.5 dV**.+**Current drop delta**  — decreases charging current down to **Battery min I**  as the battery reaches maximum voltage on specified voltage range, in volts (**dV**). Select of values from **0.0dV**  to **20.0 dV**  in increments of **0.5 dV**.
  
-**Supply max I** — maximum power supply current, in amperes (**А**). Select of values from **2.0 A** to **150.0 A**, in increments of **0.5 A**.+**Supply max I**  — maximum power supply current, in amperes (**А**). Select of values from **2.0 A**  to **150.0 A**, in increments of **0.5 A**.
  
-**Supply drop U** — allowable voltage drop on wires or power supply, in volts (**V**). Select of values from **0.50 V** to **10.00 V**, in increments of **0.25 V**. \\+**Supply drop U**  — allowable voltage drop on wires or power supply, in volts (**V**). Select of values from **0.50 V**  to **10.00 V**, in increments of **0.25 V**.
  
-**Max motor t°** — setting the limitation of the heating temperature of the motor during charging, in degrees Celsius (**°C**). Select of values from **50°C** to **120°C**, in increments of **5°C**. \\+**Max motor t°**  — setting the limitation of the heating temperature of the motor during charging, in degrees Celsius (**°C**). Select of values from **50°C**  to **120°C**, in increments of **5°C**.
  
-Below in the menu section, through the **#** sign, the real-time values of voltages and currents are shown: \\ +Below in the menu section, through the **#**  sign, the real-time values of voltages and currents are shown: \\ **# Battery I** \\ **# Battery U** \\ **# Supply I** \\ **# Supply U**
-**# Battery I** \\ +
-**# Battery U** \\ +
-**# Supply I** \\ +
-**# Supply U** \\+
  
 After plugging in the power supply, the On-board Computer will display the battery charging process. After plugging in the power supply, the On-board Computer will display the battery charging process.
  
-{{{:ru:controller:charging.png?nolink |}} **Indication to the right:**\\ +{{:ru:controller:charging.png?nolink&  }}**Indication to the right:** \\ **-22.1A**  — information line parameter, depending on the On-Board Computer settings. \\ **0:0:58**  — time elapsed since charging started, hours, minutes, seconds. \\ **I24.9**  — charging current, in Amperes (**A**). \\ **U53.7**  — charging voltage, in Volts (**V**).
-**-22.1A** — information line parameter, depending on the On-Board Computer settings. \\ +
-**0:0:58** — time elapsed since charging started, hours, minutes, seconds. \\  +
-**I24.9** — charging current, in Amperes (**A**). \\ +
-**U53.7** — charging voltage, in Volts (**V**). \\+
  
-**The indication in the middle** is the temperature of the motor and the controller, respectively, in degrees Celsius (**°C**).+**The indication in the middle**  is the temperature of the motor and the controller, respectively, in degrees Celsius (**°C**).
  
-**Indication to the left:** \\ +**Indication to the left:** \\ **59.0V**  — information line parameter, depending on the On-Board Computer settings. \\ **15Wh**  — the battery capacity in Watt hours (**Wh**). \\ **100%**  — the battery level, in percent (**%**). \\ **I24.9**  — the battery current, in Amperes (**A**). \\ **U53.7**  — the battery voltage, in Volts (**V**).
-**59.0V** — information line parameter, depending on the On-Board Computer settings. \\ +
-**15Wh** — the battery capacity in Watt hours (**Wh**). \\ +
-**100%** — the battery level, in percent (**%**). \\ +
-**I24.9** — the battery current, in Amperes (**A**). \\ +
-**U53.7** — the battery voltage, in Volts (**V**). \\+
  
- +~~CL~~
-~~CL~~ \\+
  
 ===== I/O port configuration ===== ===== I/O port configuration =====
  
-In the **Controller** > **I/O configuration** menu section, you can configure the ports functions. The controller has eight digital ports that can be configured for different functions — **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M**. See section **[[en:controller:setup#connection_diagram|Connection diagram]]**. \\+In the **Controller**  > **I/O configuration**  menu section, you can configure the ports functions. The controller has eight digital ports that can be configured for different functions — **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M**. See section **[[:en:controller:setup#connection_diagram|Connection diagram]]**. 
 + 
 +Sixteen CAN ports are additionally available **CAN port 1**  - **CAN port 16**, the signal source for which can be configured on the On-board computer or uLight. These are software values, there are fewer physical inputs on the boards, at the moment there are eight CAN ports **IO1**  - **IO8**  available in the On-board computer plus four Hotkeys (buttons on the On-board computer). In the future, six CAN ports ** I1 **  - ** I6 **  will be added to the uLight board. 
 + 
 +{{:en:controller:ports_en.png?nolink& |}}
  
-Sixteen CAN ports are additionally available **CAN port 1** **CAN port 16**, the signal source for which can be configured on the On-board computer or uLightThese are software valuesthere are fewer physical inputs on the boards, at the moment there are eight CAN ports **IO1** **IO8** available in the On-board computer plus four Hotkeys (buttons on the On-board computer). In the future, six CAN ports ** I1 ** ** I6 ** will be added to the uLight board. \\+In the section **Controller**  > **I/O configuration**  > **Port state**, you can check input activation when contact shorted to GNDWhen a signal is applied, the value will change from **Off**  to **On**. Below in the menu items **# Throttle**  and **# Brake**  you can see the voltage on the throttle and brake levers, respectively. \\
  
-{{:en:controller:k23_en.png?nolink |}}+If the controls are connected to the On-board computer, then it is necessary to check the activation when contact shorted to GND in the **On-board computer** > **Information** [[en:display:start#information|menu]]
  
-In the section **Controller** > **I/O configuration** > **Port state**, you can check input activation when contact shorted to GND. When a signal is applied, the value will change from **0** to **1**. Below in the menu items **# Throttle** and **# Brake** you can see the voltage on the throttle and brake levers, respectively. 
 ~~CL~~ \\ ~~CL~~ \\
  
-In the item ** Controller **> **I/O configuration** > **Speeds mode** you can select the method for switching additional modes **S1**, **S2**, **S3** for inputs in the Controller or CAN inputs - **Switch** or **Buttons**. \\ 
  
-{{:en:controller:k24_en.png?nolink |}}+In the item ** Controller **> **I/O configuration**  > **Speeds mode**  you can select the method for switching additional modes **S1**, **S2**, **S3**  for inputs in the Controller or CAN inputs - **Switch**  or **Buttons**\\
  
-Available functions for the Controller ports **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M** and CAN ports **CAN port 1** - **CAN port 16**\\ +{{:en:controller:k24_en.png?nolink&  }}
-**OFF** — disable port\\ +
-**RV** — reverse. \\ +
-**CRe** — enable cruise. \\ +
-**CR+** — increment cruise speed (when cruise is active). \\ +
-**CR-** —  decrement cruise speed (when cruise is active). \\ +
-**CRr** — restore last saved cruise speed with button, activated only above min cruise speed. \\ +
-**BK** — brake button. \\ +
-**DM** — disable motor (disable throttle, brake and PAS). \\ +
-**DTH** — disable throttle. \\ +
-**DPAS** — disable PAS. \\ +
-**SWSNS** — input for Gearsensor to reduce motor torque (WIP). In development. \\ +
-**N** — activates the neutral mode forcibly, resets speed mode counter if used. If neutral is activated by default, you need to change speed mode again to exit neutral. \\ +
-**nBK** — inverted brake button input, activates the brake when the contact is opened. \\ +
-**S1** — speed 1. \\ +
-**S2** — speed 2. \\ +
-**S3** — speed 3. \\ +
-**S1of3** — speed 1 for 3-position switch. \\ +
-**S3of3** — speed 3 for 3-position switch. \\ +
-**Scyc** — cycle speed mode, sequential switching with one button. \\ +
-**S++** — increment speed, switching the speed from low to high with one button. \\ +
-**S--** — decrement speedи, switching the speed from high to low with one button. \\ +
-**SPSNS** — input for external speed sensor. \\ +
-**Spec.** — special port function (like PWM or PAS). \\+
  
-Further in the menu, there are items for configuring the PWM outputs.  +Available functions for the Controller ports **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M**  and CAN ports **CAN port 1**  - **CAN port 16**: \\ **OFF**  — disable port. \\ **RV**  — reverse. \\ **CRe**  — enable cruise. \\ **CR **  — increment cruise speed (when cruise is active). \\ **CR-**  — decrement cruise speed (when cruise is active). \\ **CRr**  — restore last saved cruise speed with button, activated only above min cruise speed. \\ **BK**  — brake button. \\ **DM**  — disable motor (disable throttle, brake and PAS). \\ **DTH**  — disable throttle. \\ **DPAS**  — disable PAS. \\ **SWSNS**  — input for Gearsensor to reduce motor torque (WIP). In development. \\ **N**  — activates the neutral mode forcibly, resets speed mode counter if used. If neutral is activated by default, you need to change speed mode again to exit neutral. \\ **nBK**  — inverted brake button input, activates the brake when the contact is opened. \\ **S1**  — speed 1. \\ **S2**  — speed 2. \\ **S3**  — speed 3. \\ **S1of3**  — speed 1 for 3-position switch. \\ **S3of3**  — speed 3 for 3-position switch. \\ **Scyc**  — cycle speed mode, sequential switching with one button. \\ **S++ **  — increment speed, switching the speed from low to high with one button. \\ **S--**  — decrement speedи, switching the speed from high to low with one button. \\ **SPSNS**  — input for external speed sensor. \\  
-~~CL~~ \\ +**Spec.**  — special port function (like PWM or PAS). \\ 
-==== PWM output setup  ====+**CL1**-**CL5** — instant configuration import by pressing the CAN button (up to five different configurations). For correct import, the function number must match the number in the name of your configuration file. For example, a **CL3** function would correspond to a file called **ncconf3.cfg**. 
 + 
 +Further in the menu, there are items for configuring the PWM outputs. 
 + 
 +~~CL~~ 
 + 
 +==== PWM output setup ====
  
-To activate the **PWM P1** or **PWM P2** output, the **Controller** > **Port Setup** menu should be set to **Spec.** mode and **PAS** disabled. \\+To activate the **PWM P1**  or **PWM P2**  output, the **Controller**  > **Port Setup**  menu should be set to **Spec.**  mode and **PAS**  disabled.
  
-**PWM freq** — selection of frequency of additional PWM output on ports **P1/P2**. Select of values PWM frequency — **100Hz**, **500Hz**, **1kHz**, **5kHz**, **10kHz**, **24kHz (FAN)**. For a conventional light bulb, large values are not needed. Select the frequency **100Hz**, this will be enough to avoid flickering. The high frequency marked ** FAN ** is used to control the fan, this is their standard frequency. \\+**PWM freq**  — selection of frequency of additional PWM output on ports **P1/P2**. Select of values PWM frequency — **100Hz**, **500Hz**, **1kHz**, **5kHz**, **10kHz**, **24kHz (FAN)**. For a conventional light bulb, large values are not needed. Select the frequency **100Hz**, this will be enough to avoid flickering. The high frequency marked ** FAN **  is used to control the fan, this is their standard frequency.
  
-**PWM P1** and **PWM Р2** — selection of operating modes: \\ +**PWM P1**  and **PWM Р2**  — selection of operating modes:
-  * **Disabled** — mode not selected. \\ +
-  * **Stop-light** — activated when the brake is pressed. \\ +
-  * **Headlight** — activated when the controller is enabled. \\ +
-  * **t°C motor** — activated beyond the two deltas of the motor temperature, as the motor heats up will increase the PWM duty ( Delta °t set up on menu **Controller** > **Motor setup** > **Motor t°-sensor**). \\ +
-  * **t°C controller** — activated from 40°С, maximum value at 80°С temperature of the Controller. \\+
  
-**PWM Pn Min** / **Max** — indicates the output range of the PWM (duty), select of values from **0%** to **100%**, in increments **1%**. \\ +  * **Disabled**  — mode not selected. 
-**PWM Pn t° Min** / **t° Max** — selection of motor or controller temperature,  select of values from **0°С** to **100°С**, in increments **1°С**.+  * **Stop-light**  — activated when the brake is pressed. 
 +  * **Headlight**  — activated when the controller is enabled. 
 +  * **t°C motor**  — activated beyond the two deltas of the motor temperature, as the motor heats up will increase the PWM duty ( Delta °t set up on menu **Controller**  > **Motor setup**  > **Motor t°-sensor**). 
 +  * **t°C controller**  — activated from 40°С, maximum value at 80°С temperature of the Controller. 
 +**PWM Pn Min**  / **Max**  — indicates the output range of the PWM (duty), select of values from **0%**  to **100%**, in increments **1%**. \\ **PWM Pn t° Min**  / **t° Max**  — selection of motor or controller temperature, select of values from **0°С**  to **100°С**, in increments **1°С**.
  
 ===== Extra parameters ===== ===== Extra parameters =====
  
-In the menu section **Controller** > **Extra parameters** you can set up various additional settings of the Controller.+In the menu section **Controller**  > **Extra parameters**  you can set up various additional settings of the Controller.
  
 ==== The power button and auto shutdown ==== ==== The power button and auto shutdown ====
  
-The controller power button is located on the back of the On-Board Computer. In the **Controller** > **Extra parameters** > **Disable button** menu item, you can select the way to turn on/off the Controller, which turns on when it is powers-up or the button contacts are closed. In the off mode, the controller consumes about 100 μA, so if you reconnect the power supply without discharging the capacitors, the controller may not start. \\+The controller power button is located on the back of the On-Board Computer. In the **Controller**  > **Extra parameters**  > **Disable button**  menu item, you can select the way to turn on/off the Controller, which turns on when it is powers-up or the button contacts are closed. In the off mode, the controller consumes about 100 μA, so if you reconnect the power supply without discharging the capacitors, the controller may not start.
  
-{{:en:controller:k25_en.png?nolink |}}+{{:en:controller:k25_en.png?nolink&  }}
  
-Selecting modes for **Disable button**: \\ +Selecting modes for **Disable button**: \\ **None**  — the controller turns on when it is power-up up or when the power button is closed, does not turn off. \\ **Switch**  — the controller turns on when the power button is closed (when EN shorted to GND), turns off when it opens. \\ **Button**  — the controller turns on the button on the On-Board Computer, press it for 2 seconds, and release, to disable it, press and hold the button again. \\ **CAN**  — the controller turns on when it is powers-up or the button contacts shorts, disables only when another device on CAN bus will send a request to disable. This function is used when there are several controllers on a system, where one of them is set to button or switch mode, and the other in CAN mode.
-**None** — the controller turns on when it is power-up up or when the power button is closed, does not turn off. \\ +
-**Switch** — the controller turns on when the power button is closed (when EN shorted to GND), turns off when it opens. \\ +
-**Button** — the controller turns on the button on the On-Board Computer, press it for 2 seconds, and release, to disable it, press and hold the button again. \\ +
-**CAN** — the controller turns on when it is powers-up or the button contacts shorts, disables only when another device on CAN bus will send a request to disable. This function is used when there are several controllers on a system, where one of them is set to button or switch mode, and the other in CAN mode. \\+
  
-**Auto shutdown** — activation of the controller shutdown function after a while if the motor does not spin. Select of values **On** and **Offл**. The shutdown time is set in item **Sleep time**. \\+**Auto shutdown**  — activation of the controller shutdown function after a while if the motor does not spin. Select of values **On**  and **Offл**. The shutdown time is set in item **Sleep time**.
  
-**Sleep time** — selection of the controller shutdown time when the **Auto shutdown** function is activated, in seconds, (**s**). Select of values from **30s** to **1500s**, in increments of **5s**. \\+**Sleep time**  — selection of the controller shutdown time when the **Auto shutdown**  function is activated, in seconds, (**s**). Select of values from **30s**  to **1500s**, in increments of **5s**.
  
-**Lock at turn-on** — the function locks controller inputs when enabled until the password is entered on the On-Board Computer, if there is no On-Board Computer, enabling this setting will permanently lock the controller.+**Lock at turn-on**  — the function locks controller inputs when enabled until the password is entered on the On-Board Computer, if there is no On-Board Computer, enabling this setting will permanently lock the controller.
  
 ==== Speedometer setup ==== ==== Speedometer setup ====
  
-The next block of settings in the menu section **Controller** > **Extra parameters** refers to the speed calculation setting. If you use an external speed sensor connected to the On-board computer, you need to configure it in menu **[[en:display:start#data_sources_setup|Data source setup]]**.+The next block of settings in the menu section **Controller**  > **Extra parameters**  refers to the speed calculation setting. If you use an external speed sensor connected to the On-board computer, you need to configure it in menu **[[:en:display:start#data_sources_setup|Data source setup]]**.
  
-{{:en:controller:k26_en.png?nolink |}}+{{:en:controller:k26_en.png?nolink&  }}
  
-**Speed calculation** — enabling speed calculation in the Controller. Useful for multi-motor configurations, you can turn off the speed calculation on some motors. Select of values **On** and **Off**. \\+**Speed calculation**  — enabling speed calculation in the Controller. Useful for multi-motor configurations, you can turn off the speed calculation on some motors. Select of values **On**  and **Off**.
  
-**Circumference** — wheel circumference, in millimeters (mm). Select of values from **0mm** to **3000mm**, in increments of **5mm**. To calculate the circumference, you can use [[https://www.omnicalculator.com/math/circumference|online calculator]]. \\+**Circumference**  — wheel circumference, in millimeters (mm). Select of values from **0mm**  to **3000mm**, in increments of **5mm**. To calculate the circumference, you can use [[https://www.omnicalculator.com/math/circumference|online calculator]].
  
-**Motor sprocket** — this setting specifies the number of sprocket teeth on the motor (notional), which allows you to set the gear ratio from motor shaft to the wheel. Also, this setting can be used as a reduction ratio for gear motors. \\+**Motor sprocket**  — this setting specifies the number of sprocket teeth on the motor (notional), which allows you to set the gear ratio from motor shaft to the wheel. Also, this setting can be used as a reduction ratio for gear motors.
  
-**Wheel sprocket** — the number of teeth of the wheel sprocket, similar to the setting **Motor sprocket**. \\+**Wheel sprocket**  — the number of teeth of the wheel sprocket, similar to the setting **Motor sprocket**.
  
-If you have a wheel motor, then in the section **Controller** > **Motor setup** you need to specify the number of **Pole pair** (divide the number of magnets by two). For gear motors or mid-drives, it is recommended to install an external speed sensor that connects to the Onboard computer or to any of the controller ports.+If you have a wheel motor, then in the section **Controller**  > **Motor setup**  you need to specify the number of **Pole pair**  (divide the number of magnets by two). For gear motors or mid-drives, it is recommended to install an external speed sensor that connects to the Onboard computer or to any of the controller ports.
  
 ==== Master-controller ==== ==== Master-controller ====
  
-{{:en:controller:k27_en.png?nolink |}} +{{:en:controller:k27_en.png?nolink&  }}In the menu section **Controller**  > **Extra parameters**  > **Master-controller**  you can enable the function of controlling other controllers from the current one. This setting is suitable for multi-motor configurations where control (throttle, brake and etc.) is connected into one of the controllers directly. 
-In the menu section **Controller** > **Extra parameters** > **Master-controller** you can enable the function of controlling other controllers from the current one. This setting is suitable for multi-motor configurations where control (throttle, brake and etc.) is connected into one of the controllers directly. + 
-~~CL~~ \\+~~CL~~
  
 ==== Other settings ==== ==== Other settings ====
  
-{{:en:controller:4_0.8.png?nolink |}} +{{:en:controller:4_0.8.png?nolink&  }}**Limit t° CPU**  — limiting the temperature of the processor, in degrees Celsius (**°C**). When the specified threshold is reached, the phase current will be limited. Select of values from **60°C**  to **105°C**, in increments of **5°C**.
-**Limit t° CPU** — limiting the temperature of the processor, in degrees Celsius (**°C**). When the specified threshold is reached, the phase current will be limited. Select of values from **60°C** to **105°C**, in increments of **5°C**. \\+
  
-**Device ID** — setting the Controller number in the CAN network. This number is displayed in the menu section **Settings** > **Devices** in front of each device that is connected to the network using the [[en:levcan|LEVCAN protocol]]. If, by default, your device number is **0**, we recommend changing it to another number for the correct firmware update.+**Device ID**  — setting the Controller number in the CAN network. This number is displayed in the menu section **Settings**  > **Devices**  in front of each device that is connected to the network using the [[:en:levcan|LEVCAN protocol]]. If, by default, your device number is **0**, we recommend changing it to another number for the correct firmware update.
  
-**Prefix 1** and **Prefix 2** — controller name setting for multi-motor configurations. Using the prefixes together or separately, you can specify where the electric motor that the Controller controls is located. The selectable values for each prefix are **None**, **Front**, **Rear**, **Left**, **Right**. To save the setting, go to the **Controller** > **Save settings** menu item and select **On**, then restart the controller. The prefix will now appear in front of the controller name in the **Devices** menu. \\+**Prefix 1**  and **Prefix 2**  — controller name setting for multi-motor configurations. Using the prefixes together or separately, you can specify where the electric motor that the Controller controls is located. The selectable values for each prefix are **None**, **Front**, **Rear**, **Left**, **Right**. To save the setting, go to the **Controller**  > **Save settings**  menu item and select **On**, then restart the controller. The prefix will now appear in front of the controller name in the **Devices**  menu.
  
-For example, you have a 2WD scooter and two 12F controllers, you need to distinguish them somehow in the **Devices** menu for easy setup. A controller for a front motor can be prefixed with **Front**, in which case the controller will be named **Front Nucular controller** in the **Devices** menu. \\+For example, you have a 2WD scooter and two 12F controllers, you need to distinguish them somehow in the **Devices**  menu for easy setup. A controller for a front motor can be prefixed with **Front**, in which case the controller will be named **Front Nucular controller**  in the **Devices**  menu.
  
-If you are using a 3WD drive or more, then both prefixes must be used for the controller name. For example, if the controller is driving a rear right motor, the setting will look like this: **Prefix 1** — **Rear**, **Prefix 2** — **Right**. \\+If you are using a 3WD drive or more, then both prefixes must be used for the controller name. For example, if the controller is driving a rear right motor, the setting will look like this: **Prefix 1**  — **Rear**, **Prefix 2**  — **Right**.
  
 ===== PID regulators ===== ===== PID regulators =====
  
-In the **Controller** > **PID regulators** menu section, various signals of proportional-integral-derivative (PID) regulators are configured - devices in the control loop with feedback used in automatic control systems to generate a control signal in order to obtain the required accuracy and the quality of the transition process. **Settings for advanced users**. \\ +In the **Controller**  > **PID regulators**  menu section, various signals of proportional-integral-derivative (PID) regulators are configured - devices in the control loop with feedback used in automatic control systems to generate a control signal in order to obtain the required accuracy and the quality of the transition process. **Settings for advanced users**.
  
-{{:en:controller:k28_en.png?nolink |}} +{{:en:controller:k28_en.png?nolink&  }}Two or three coefficients are used for the settings of each regulator: \\ **Ki**  — integral coefficient. \\ **Кp**  — proportional coefficient. \\ **Kd**  — differentiating coefficient
-Two or three coefficients are used for the settings of each regulator: \\ + 
-**Ki** — integral coefficient. \\  +**Square Ki, Kp**  — phase current regulator for a square wave. \\ **FOC Ki, Kp**  — phase current regulator for FOC mode. \\ **FW Ki, Kp**  — field weakening coefficients. \\ **DCv Ki, Kp**  — voltage regulator on the DC bus. \\ **DCi Ki, Kp**  — current regulator on the DC bus. \\ **DCw Ki, Kp**  — power calculator. \\ **Speed Ki, Kp, Kd**  — speed regulator for throttle control modes **Speed**  and **Speed torque**. \\ **PLL Ki, Kp**  — speed regulator for motor angle interpolation. \\ **Acceleration Kp, Ki**  — deceleration and acceleration regulator. 
-**Кp** — proportional coefficient. \\ + 
-**Kd** — differentiating coefficient. \\+~~CL~~
  
-**Square Ki, Kp** — phase current regulator for a square wave. \\ 
-**FOC Ki, Kp** — phase current regulator for FOC mode. \\ 
-**FW Ki, Kp** — field weakening coefficients. \\ 
-**DCv Ki, Kp** — voltage regulator on the DC bus. \\ 
-**DCi Ki, Kp** — current regulator on the DC bus. \\ 
-**DCw Ki, Kp** — power calculator. \\ 
-**Speed Ki, Kp, Kd** — speed regulator for throttle control modes **Speed** and **Speed+torque**. \\ 
-**PLL Ki, Kp** — speed regulator for motor angle interpolation. \\ 
-**Acceleration Kp, Ki** — deceleration and acceleration regulator. 
-~~CL~~ \\ 
 ===== Status flags ===== ===== Status flags =====
  
-The **Controller** > **Status Flags** menu section displays errors that may occur during the operation of the Controller. If an error occurs, the parameter value changes to **On**.\\+The **Controller**  > **Status Flags**  menu section displays errors that may occur during the operation of the Controller. If an error occurs, the parameter value changes to **On**.
  
-{{:en:controller:k29_en.png?nolink |}}+{{:en:controller:flags_0808.png?nolink|}}
  
-**Reset?** — reset all statuses. Values **On** and **Off**. \\ +**Reset?**  — reset all statuses. Values **On** and **Off**. \\  
-**Max acceleration** — maximum acceleration, in ERPM/s. \\ +**Max acceleration**  — maximum acceleration, in ERPM/s. \\  
-**Min deceleration** — maximum deceleration, in ERPM/s. \\ +**Min deceleration**  — maximum deceleration, in ERPM/s. \\  
-**Overload current** — the last recorded current on the phases, in Amperes. \\ +**Overload current**  — the last recorded current on the phases, in Amperes. \\  
-**Overload** — exceeding the permissible current values. Values **On** and **Off**. \\ +**Overload**  — exceeding the permissible current values. Values **On**  and **Off**. \\  
-**Over-Field weakening** — weakening error. Values **On** and **Off**. \\ +**Over-Field weakening**  — weakening error. Values **On**  and **Off**. \\  
-**Supply overvoltage** — too high supply voltage, the error will appear above 95V, but in general depends on the controller model. Values **On** and **Off**. \\ +**Supply overvoltage**  — too high supply voltage, the error will appear above 95V, but in general depends on the controller model. Values **On** and **Off**. \\  
-**Supply undervoltage** — too low supply voltage, less than the minimum battery supply threshold. Values **On** and **Off**. \\ +**Supply undervoltage**  — too low supply voltage, less than the minimum battery supply threshold. Values **On**  and **Off**. \\  
-**12V protection** — breaking down or error on the 12V power line. Values **On** and **Off**. \\ +**12V protection** — error on the 12V power line. Values **On** and **Off**. \\ 
-**Brake error** — brake lever connection error. Values **On** and **Off**. \\ +**Control fail** — the controller was not able to smoothly turn off the electric motor in time when the brake contacts were closed. Values **On** and **Off**. 
-**Throttle error** — throttle lever connection error. Values **On** and **Off**. \\ +**12V protection**  — breaking down or error on the 12V power line. Values **On**  and **Off**. \\  
-**Hall error** — Hall sensor connection error. Values **On** and **Off**. \\ +**Brake error**  — brake lever connection error. Values **On**  and **Off**. \\  
-**Code error** — error executing firmware code. Values **On** and **Off**. Let us know if this error occurs. \\ +**Throttle error**  — throttle lever connection error. Values **On**  and **Off**. \\  
-**PAS protection** — PAS error. Values **On** and **Off**. \\ +**Hall error**  — Hall sensor connection error. Values **On**  and **Off**. \\  
-**Controller overheat** — overheat protection of the controller. Values **On** and **Off**. \\ +**Code error**  — error executing firmware code. Values **On**  and **Off**. Let us know if this error occurs. \\  
-**Motor overheat** — overheating protection of the electric motor. Values **On** and **Off**. \\ +**Thread error** — processor overload. Values **On** and **Off**. The error is not critical, let us know if it occurs. \\ 
-**Protection fail** — hardware error, malfunction of all protection systems during controller self-test. If this error occurs, the operation of the Controller will be impossible. Values **On** and **Off**. \\ +**PAS protection**  — PAS error. Values **On**  and **Off**. \\  
-**Voltage on phases** — overvoltage on phases. Values **On** and **Off**. \\ +**Controller overheat**  — overheat protection of the controller. Values **On**  and **Off**. \\  
-**CAN: error** — CAN-bus errors. Values **On** and **Off**. Let us know if this error occurs. \\ +**Motor overheat**  — overheating protection of the electric motor. Values **On**  and **Off**. \\  
-**LEC** — types of errors on the CAN bus. If everything is alright you will see the value **Ok**. In case of errors, there will be values -  **Stuff**, **Form**, **Acknowledgment**, **Bit recessive**, **Bit dominant**, **CRC**, **SW**. Tell us the code if this error occurs. \\ +**Protection fail**  — hardware error, malfunction of all protection systems during controller self-test. If this error occurs, the operation of the Controller will be impossible. Values **On**  and **Off**. \\  
-**Receive w/error** — CAN-bus errors on receiving. \\ +**ADC sample error** — software error of the analog-to-digital converter (ADC). Values **On** and **Off**. \\ 
-**Sent w/error** — CAN-bus errors on transmitting. \\ +**VBUS sample error** — supply voltage measurement error. Values **On** and **Off**. \\ 
-**CAN state** — overloading buffers. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **OVR0**, **OVR1**, **OVR01**. Tell us the code if this error occurs. \\ +**Voltage on phases**  — overvoltage on phases. Values **On**  and **Off**. \\  
-**CPU Load** — current load of the central processor, in percentage (**%**).+**LEC**  — types of errors on the CAN bus. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **Stuff**, **Form**, **Acknowledgment**, **Bit recessive**, **Bit dominant**, **CRC**, **SW**. Tell us the code if this error occurs. \\  
 +**Receive w/error**  — CAN-bus errors on receiving. \\  
 +**Sent w/error**  — CAN-bus errors on transmitting. \\  
 +**CAN state**  — overloading buffers. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **OVR0**, **OVR1**, **OVR01**. Tell us the code if this error occurs. \\  
 +**CAN RX** — the number of messages in the CAN bus to receive. \\ 
 +**CAN TX** — the number of messages in the CAN bus to transmission. \\ 
 +**CPU Load**  — current load of the central processor, in percentage (**%**).
  
 ===== Debug information ===== ===== Debug information =====
  
-The menu section **Controller** > **Debug information** shows the main parameters of your Controller, electric motor, and the whole system - temperature, rpm, voltage, and current, as well as the values of the current regulators. \\+The menu section **Controller**  > **Debug information**  shows the main parameters of your Controller, electric motor, and the whole system - temperature, rpm, voltage, and current, as well as the values of the current regulators.
  
-{{:en:controller:k30_en.png?nolink |}} +{{:en:controller:debug_0808.png?nolink|}}
  
-**Temp FET** — temperature of the field-effect transistors (MOSFETs) of the Controller, in degrees Celsius (**°C**). \\ +**Temp. controller**  — temperature of the Controller, in degrees Celsius (**°C**). \\  
-**Temp Motor** — temperature of the electric motor, in degrees Celsius (**°C**). \\ +**Temp. motor**  — temperature of the electric motor, in degrees Celsius (**°C**). \\  
-**DC current** — DC current, in amperes (**А**). \\ +**DC current**  — DC current, in amperes (**А**). \\  
-**DC voltage** — DC voltage, in volts (**V**). \\ +**DC voltage**  — DC voltage, in volts (**V**). \\  
-**AC current** — AC current, in amperes (**А**). \\ +**AC current**  — AC current, in amperes (**А**). \\  
-**AC voltage** — AC voltage, in volts (**V**). \\ +**AC voltage**  — AC voltage, in volts (**V**). \\  
-**Motor U0** — DC voltage on phases, in volts (**V**). \\ +**Motor U0**  — DC voltage on phases, in volts (**V**). \\  
-**System 12V** — voltage on the CAN bus 12V, in volts (**V**). \\ +**System 12V**  — voltage on the CAN bus 12V, in volts (**V**). \\  
-**System 5V** — voltage on the CAN bus 5V, in volts (**V**). \\ +**System 5V**  — voltage on the CAN bus 5V, in volts (**V**). \\  
-**RPM** — motor speed, in RPM (**RPM**). \\ +**RPM**  — motor speed, in RPM (**RPM**). \\ **ERPM**  — electric revolutions of the motor per minute (**ERPM**). \\  
-**ERPM** — electric revolutions of the motor per minute (**ERPM**). \\ +**Hall input**  — this parameter allows you to check the functionality of the Hall sensors. There are three digits in this item, each shows the signal level, if you rotate the motor slowly by hand, all three digits should change. If none of the digits change, check if the Hall connector is connected or the ground may be broken. If one of the digits does not change - there is no contact or the sensor wire is broken. To check the contacts in the controller, disconnect the Hall connector and measure the voltages on the controller connector. There should be about 4V on the signal lines of the Halls, 5V on the power supply, and about 3V on the temperature sensor line. \\  
-**Hall input** — this parameter allows you to check the functionality of the Hall sensors. There are three digits in this item, each shows the signal level, if you rotate the motor slowly by hand, all three digits should change. If none of the digits change, check if the Hall connector is connected or the ground may be broken. If one of the digits does not change - there is no contact or the sensor wire is broken. To check the contacts in the controller, disconnect the Hall connector and measure the voltages on the controller connector. There should be about 4V on the signal lines of the Halls, 5V on the power supply, and about 3V on the temperature sensor line. \\ +**Hall index**  — virtual position of the motor, digits from 1 to 6 (normal operation). \\  
-**Hall index** — virtual position of the motor, digits from 1 to 6 (normal operation). \\ +**Throttle %**  — the percentage of how much the throttle is pressed. \\  
-**Throttle %** — the percentage of how much the throttle is pressed. \\ +**Brake %**  — the percentage of how much the brake is pressed. \\  
-**Brake %** — the percentage of how much the brake is pressed. \\ +**Speed request**  — set point for the speed regulator, in eRPM. \\  
-**Speed request** — set point for the speed regulator, in eRPM. \\ +**Torque request**  — phase current request, either positive throttle or a negative brake. \\  
-**Torque request** — phase current request, either positive throttle or a negative brake. \\ +**Torque limit**  — current limit for this type of controller, taking into account overheating. \\  
-**Torque limit** — current limit for this type of controller, taking into account overheating. \\ +**Temp CPU**  — CPU temperature, in degrees Celsius (**°C**). \\ 
-**Temp CPU** — CPU temperature, in degrees Celsius (**°C**).+ 
 +Next in the menu are the sections **Debug FOC**  and **Remote inputs**, which are described below.
  
-Next in the menu are the sections **Debug FOC** and **Remote inputs**, which are described below. 
-  
 ==== Debug FOC ==== ==== Debug FOC ====
  
-In the menu section **Controller** > **Debug information** > **Debug FOC** \\+In the menu section **Controller**  > **Debug information**  > **Debug FOC**
  
-{{:en:controller:k31_en.png?nolink |}}+{{:en:controller:k31_en.png?nolink&  }} 
 + 
 +**U Q**  — Q-axis voltage, in volts (**V**). \\ **U D**  — D-axis voltage, in volts (**V**). \\ **I Q**  — Q-axis current, in amperes (**А**). \\ **I D**  — D-axis current, in amperes (**А**). \\ **Ireqest Q**  — Q-axis current request, in amperes (**А**). \\ **Ireqest D**  — D-axis current request, in amperes (**А**). 
 + 
 +~~CL~~
  
-**U Q** — Q-axis voltage, in volts (**V**). \\ 
-**U D** — D-axis voltage, in volts (**V**). \\ 
-**I Q** — Q-axis current, in amperes (**А**). \\ 
-**I D** — D-axis current, in amperes (**А**). \\ 
-**Ireqest Q** — Q-axis current request, in amperes (**А**). \\ 
-**Ireqest D** — D-axis current request, in amperes (**А**).  
-~~CL~~ \\ 
 ==== Remote inputs ==== ==== Remote inputs ====
  
-In the menu section **Controller** > **Debug information** > **Remote inputs** you can view the parameters of the throttle and brake levers connected to other devices connected to the CAN-bus (On-board computer or uLight). \\+In the menu section **Controller**  > **Debug information**  > **Remote inputs**  you can view the parameters of the throttle and brake levers connected to other devices connected to the CAN-bus (On-board computer or uLight). 
 + 
 +{{:en:controller:k32_en.png?nolink&  }}**Throttle**  — voltage on the throttle lever at a remote source (On-board computer or uLight), in volts (**V**). \\ **Brake**  — voltage at the brake lever at a remote source (On-board computer or uLight), in volts (**V**). \\ **Throttle % **— the percentage of how much the throttle pressed at a remote source. \\ **Brake %**  — the percentage of how much the brake pressed at a remote source. 
 + 
 +~~CL~~
  
-{{:en:controller:k32_en.png?nolink |}} 
-**Throttle** — voltage on the throttle lever at a remote source (On-board computer or uLight), in volts (**V**). \\ 
-**Brake** — voltage at the brake lever at a remote source (On-board computer or uLight), in volts (**V**). \\ 
-**Throttle % **— the percentage of how much the throttle pressed at a remote source. \\ 
-**Brake %** — the percentage of how much the brake pressed at a remote source. 
-~~CL~~ \\ 
 ===== Logger ===== ===== Logger =====
  
-In the **Controller ** > **Logger** menu section, you can enable and configure the data logging during the operation of the Controller. This functionality is experimental, errors may occur. The file is saved in ** CSV ** format to an SD card inserted into the On-board computer. To view the file, you can use the service [[https://datazap.me/|Datazap]]. The SD card must have a FAT32 file system.+In the **Controller **  > **Logger**  menu section, you can enable and configure the data logging during the operation of the Controller. This functionality is experimental, errors may occur. The file is saved in ** CSV **  format to an SD card inserted into the On-board computer. To view the file, you can use the service [[https://datazap.me/|Datazap]]. The SD card must have a FAT32 file system.
  
-{{:en:controller:11_0.8.png?nolink |}}+{{:en:controller:11_0.8.png?nolink&  }}
  
-**Start logging** — to start recording, select **On** and press the right button of the On-board computer. After that, the **#State** menu item will change to **Waiting** status. The recording will start automatically after pressing the throttle grip. If an error occurs during the recording process, you will see its code in the ** # Error code ** menu item. In case of an error, firstly, check that the SD card has the FAT32 file system, and secondly, that there is free space on the SD card for recording. Additionally, you can delete unnecessary files from the card. After that, restart the Controller and start recording again. If the error repeats, contact us through the website or chat technical support and report the error code.+**Start logging**  — to start recording, select **On**  and press the right button of the On-board computer. After that, the **#State**  menu item will change to **Waiting**  status. The recording will start automatically after pressing the throttle grip. If an error occurs during the recording process, you will see its code in the ** # Error code **  menu item. In case of an error, firstly, check that the SD card has the FAT32 file system, and secondly, that there is free space on the SD card for recording. Additionally, you can delete unnecessary files from the card. After that, restart the Controller and start recording again. If the error repeats, contact us through the website or chat technical support and report the error code.
  
-**Stop logging** — stop recording, select **On** to end recording+**Stop logging**  — stop recording, select **On**  to end recording.
-~~CL~~ \\ +
-**Start mode** — selection of recording start mode:  +
-  * **Manual** — enable manual recording. +
-  * **At start** — recording starts automatically when the Controller is turned on.+
  
-**Log time** — two parameters of time for recording to choose from: +~~CL~~
-  * **Time step** — delta of time since the previous record. +
-  * **Sys time** — global time, which is incremented after the start of the controller.+
  
-**Log rate** — delay between records of values. You can choose either the number of PWM cycles (**PWM1**, **PWM2**, **PWM5**, **PWM10**), either time (**1ms**, **10ms**, **20ms**, **100ms**, **1s**, **5s**, **10s**, **30s**).+ \\ **Start mode**  — selection of recording start mode:
  
-**Mode** — recording mode selection: +  * **Manual**  — enable manual recording. 
-  * **Buffered** — buffering and recording in segments.  +  * **At start**  — recording starts automatically when the Controller is turned on. 
-  * **Max rate** — continuous recording mode.+**Log time**  — two parameters of time for recording to choose from: 
 + 
 +  * **Time step**  — delta of time since the previous record. 
 +  * **Sys time**  — global time, which is incremented after the start of the controller. 
 +**Log rate**  — delay between records of values. You can choose either the number of PWM cycles (**PWM1**, **PWM2**, **PWM5**, **PWM10**), either time (**1ms**, **10ms**, **20ms**, **100ms**, **1s**, **5s**, **10s**, **30s**). 
 + 
 +**Mode**  — recording mode selection: 
 + 
 +  * **Buffered**  — buffering and recording in segments. 
 +  * **Max rate**  — continuous recording mode. 
 +**Data averaging**  — using filters while recording:
  
-**Data averaging** — using filters while recording:  
   * **None**  — filter disabled (records real values).   * **None**  — filter disabled (records real values).
-  * **Fast** — slight averaging (smoothes values). +  * **Fast**  — slight averaging (smoothes values). 
-  * **Slow** — large averaging.+  * **Slow**  — large averaging
 +**Add header to log**  — adding the name of the controller when writing the log, so that you can understand which controller the log belongs to in multi-motors configurations. You can set the name of the controller in the menu **Controller**  > **Extra parameters**, items **Prefix 1**  and **Prefix 2**.
  
-Next, in the **# Data to log** menu sections, you can select the set of parameters you want to record. Select **On** to enable parameter recording.+Next, in the **# Data to log**  menu sections, you can select the set of parameters you want to record. Select **On**  to enable parameter recording.
  
-{{:en:controller:12_0.8.png?nolink |}}+{{:en:controller:logger_en_0504.png?nolink|}}
 **# Data to log**: \\  **# Data to log**: \\ 
-**Battery Voltage** — battery voltage data logging. \\  +**Battery Voltage**  — battery voltage data logging. \\  
-**Battery Current** — battery current data logging. \\  +**Battery Current**  — battery current data logging. \\  
-**Motor Voltage** — motor voltage data logging. \\  +**Motor Voltage**  — motor voltage data logging. \\  
-**Motor Current** — motor current data logging. \\  +**Motor Current**  — motor current data logging. \\  
-**Wheel speed** — wheel speed data logging. \\  +**Wheel speed**  — wheel speed data logging. \\  
-**Motor rad/s** — data logging of the angular speed of the electric motor. \\  +**Motor rad/s**  — data logging of the angular speed of the electric motor. \\  
-**Motor RPM** — data logging of revolutions of an electric motor per minute. \\  +**Motor RPM**  — data logging of revolutions of an electric motor per minute. \\  
-**Tmotor °C** — data logging of the electric motor temperature. \\  +**Motor angle** — data logging of the angle of the electric motor. \\ 
-**Tfet °C** — data logging the temperature of field-effect transistors. \\  +**Tmotor °C**  — data logging of the electric motor temperature. \\  
-**Raw hall input** — data logging the input status from Hall sensors without filter. \\  +**Tfet °C**  — data logging the temperature of field-effect transistors. \\  
-**Hall index** — virtual position of motor. \\  +**Raw hall input**  — data logging the input status from Hall sensors without filter. \\  
-**Throttle %** — throttle grip data logging. \\  +**Hall index**  — virtual position of the motor. \\  
-**Brake %** — brake lever data logging. \\  +**Throttle %**  — throttle grip data logging. \\  
-**FOC Vq** — Q-axis voltage data logging. \\  +**Brake %**  — brake lever data logging. \\  
-**FOC Vd** — D-axis voltage data logging. \\  +**FOC Vq**  — Q-axis voltage data logging. \\  
-**FOC Iq** — Q-axis current data logging. \\  +**FOC Vd**  — D-axis voltage data logging. \\  
-**FOC Id** — D-axis current data logging. \\  +**FOC Iq**  — Q-axis current data logging. \\  
-**FOC Iq request** — Q-axis current request data logging. \\  +**FOC Id**  — D-axis current data logging. \\  
-**FOC Id request** — D-axis current request data logging. \\  +**FOC Iq request**  — Q-axis current request data logging. \\  
-**Current phA** — data logging the current on the A phase of the electric motor. \\  +**FOC Id request**  — D-axis current request data logging. \\  
-**Current phB** — data logging the current on the B phase of the electric motor. \\  +**Current phA**  — data logging the current on the A phase of the electric motor. \\  
-**Current phC** — data logging the current on the С phase of the electric motor. \\ +**Current phB**  — data logging the current on the B phase of the electric motor. \\  
-**PAS frequency RPM** — PAS frequency data logging. \\ +**Current phC**  — data logging the current on the С phase of the electric motor. \\  
-**PAS torque Nm** — PAS torque data logging. \\ +**PAS frequency RPM**  — PAS frequency data logging. \\  
-**PAS power W** — PAS power data logging. \\ +**PAS torque Nm**  — PAS torque data logging. \\  
-**Speed request** — speed request data logging. \\ +**PAS power W**  — PAS power data logging. \\  
-**Torque request** — torque request data logging.\\+**Speed request**  — speed request data logging. \\  
 +**Torque request**  — torque request data logging.
  
 ===== Statistics ===== ===== Statistics =====
  
-In the menu section **Controller** > **Statistics** you can view the data on the Controller. These are trip statistics that will be automatically reset when the controller is powered off. If you have several Controllers in the system, then you can see the summary data for all controllers in the general statistics in the On-board computer. \\+In the menu section **Controller**  > **Statistics**  you can view the data on the Controller. These are trip statistics that will be automatically reset when the controller is powered off. If you have several Controllers in the system, then you can see the summary data for all controllers in the general statistics in the On-board computer. 
 + 
 +{{:en:controller:statistics_0808.png?nolink |}}
  
-{{:en:controller:13_0.8.png?nolink |}}+**Wh used total**  — total energy consumption (used plus regen), in Watt-hours (**Wh**). \\  
 +**Wh used**  — energy consumption, in Watt-hours (**Wh**). \\  
 +**Wh regen.**  — energy gained during the recuperation process, in Watt-hours (**Wh**). \\  
 +**Regen. %**  — the percentage of energy recovered during recuperation (**%**). \\  
 +**Ah used total**  — total energy consumption (used plus regen), in Ampere hours (**Ah**). \\  
 +**Ah used**  — energy consumption, in Ampere hours (**Ah**). \\  
 +**Ah regen.**  — energy gained during the recuperation process, in Ampere hours (**Ah**). \\ 
 +**Min bat. voltage** — minimum battery voltage, in Volts (**V**). \\ 
 +**Max phase curr.** — maximum phase current, in Amps (**A**). \\ 
 +**Peak power** — maximum motor power, in Watts (**W**). \\ 
 +**Max motor temp.** — maximum motor temperature, in degrees Celsius (**°C**). \\ 
 +**Max controller temp.** — the maximum temperature of the Controller, in degrees Celsius (**°C**)\\
  
-**Wh used total** — total energy consumption (used plus regen), in Watt-hours (**Wh**). \\ +The values below are approximate! \\  
-**Wh used** — energy consumption, in Watt-hours (**Wh**). \\ +**Motor efficiency**  — efficiency of the electric motor, in percent (**%**). \\  
-**Wh regen.** — energy gained during the recuperation process, in Watt-hours (**Wh**). \\ +**Effaverage**  — average efficiency of the electric motor, in percent (**%**). \\  
-**Regen. %** — the percentage of energy recovered during recuperation (**%**). \\  +**Torque**  — current torque of the electric motor, in Newton-meters (**Nm**). \\  
-**Ah used total** — total energy consumption (used plus regen), in Ampere hours (**Ah**).  \\ +**Power out**  — the power that the electric motor delivers, in Watts (**W**). \\  
-**Ah used**  — energy consumption, in Ampere hours (**Ah**). \\ +**Power in**  — power supplied to the electric motor, in Watts (**W**).
-**Ah regen.** — energy gained during the recuperation process, in Ampere hours (**Ah**). \\+
  
-The values below are approximate! \\ 
-**Motor efficiency** — efficiency of the electric motor, in percent (**%**). \\ 
-**Eff. average** — average efficiency of the electric motor, in percent (**%**). \\ 
-**Torque** — current torque of the electric motor, in Newton-meters (**Nm**). \\  
-**Power out** — the power that the electric motor delivers, in Watts (**W**). \\  
-**Power in** — power supplied to the electric motor, in Watts (**W**). \\  
 ===== Device information ===== ===== Device information =====
  
-In the menu section **Controller** > **Device Information** you can view the basic information about the Controller. In this menu, you can check which firmware version is loaded into your Controller, as well as other parameters that differ depending on the Controller model. \\+In the menu section **Controller**  > **Device Information**  you can view the basic information about the Controller. In this menu, you can check which firmware version is loaded into your Controller, as well as other parameters that differ depending on the Controller model.
  
-{{:en:controller:k34_en.png?nolink |}}+{{:en:controller:device_info.png?nolink|}}
  
-**Micro Nucular Controller** — device name depending on the type of Controller. \\ +**Nucular Controller**  — device name depending on the type of Controller. \\  
-**Max supply** — 95V. The warranty covers supply voltages up to **90V** inclusive. \\ +**Max supply**  — 95V. The warranty covers supply voltages up to **90V**  inclusive. \\  
-**Max current** — the value of the maximum phase current, depending on the type of Controller, in amperes (A). \\ +**Max current**  — the value of the maximum phase current, depending on the type of Controller, in amperes (A). \\  
-**Firmware date** — firmware compilation date. \\ +**Encoder speed** — 26kHz or 580kHz (new Controller version with orange phase wires). \\ 
-**Firmware ver.** — version of the installed firmware, you can check for updates in the section **[[en:firmware|Firmware]]**. \\ +**Firmware date**  — firmware compilation date. \\  
-**Loader date** — the data loader compilation date. \\ +**Firmware ver.**  — version of the installed firmware, you can check for updates in the section **[[:en:firmware|Firmware]]**. \\  
-**Loader version** — data loader version. \\ +**Loader date**  — the data loader compilation date. \\  
-**Worked** — operating time of the Controller in kilowatt-hours (kW*h). \\ +**Loader version**  — data loader version. \\  
-**t° middle 100 h** — the average temperature of the Сontroller over the last 100 hours. \\ +**Production date** — date of manufacture of the controller. \\ 
-**t° middle** — the average temperature of the Сontroller over all time. \\ +**Worked**  — operating time of the Controller in kilowatt-hours (kW*h). \\  
-**Current protections** — the number of triggered overcurrent protections over all time of operation of the controller. \\ +**t° middle 100 h**  — the average temperature of the Сontroller over the last 100 hours. \\  
-**Temperature protections** — the number of triggered temperature protections over all time of operation of the controller. \\ +**t° middle**  — the average temperature of the Сontroller over all time. \\  
-**Voltage protections** — the number of triggered voltage protections over all time of operation of the controller. \\ +**Current protections**  — the number of triggered overcurrent protections over all time of operation of the controller. \\  
-**Power cycle** — number of controller switching on. \\ +**Temperature protections**  — the number of triggered temperature protections over all time of operation of the controller. \\  
-**Power-on time** — total operating time of the Controller, minutes, hours, days.+**Voltage protections**  — the number of triggered voltage protections over all time of operation of the controller. \\  
 +**Power cycle**  — number of controller switching on. \\  
 +**Power-on time**  — total operating time of the Controller, minutes, hours, days. \\ 
 +**Serial number** — serial number of the Controller (for devices manufactured from 01 Jul 2022). Take a photo or write down this number and keep it separate from the Controller. You may need it when requesting repairs or if the Controller is stolen. After updating the firmware to 0.8.7, in some versions of controllers manufactured before 01 Jul 2022, a serial number may also appear. Check after update.