+ | ===== Firmware update ===== | ||
+ | |||
+ | In the menu section **Controller** > **Update and Settings**, you can update the Controller' | ||
+ | |||
+ | {{: | ||
+ | |||
+ | **Import config.** — loads the settings from the file ** NCconf.cfg ** - ** NCconf9.cfg ** up to a maximum of 9 different configurations, | ||
+ | **Export config.** - saves the settings to the ** NCconf.cfg ** - ** NCconf9.cfg ** file up to a maximum of 9 different configurations, | ||
+ | **Reboot** — restarts the device. If the settings have not been saved, they will be reset.\\ \\ | ||
+ | **Reset Wh usage** — resets the accumulated number of Watt-Hours in the controller. This indicator is displayed in the statistics of the On-board computer, see section **[[en: | ||
+ | **Reset stats** — resets mileage in kilometers.\\ \\ | ||
+ | **Load defaults** — after a reset, the default settings are loaded but not saved. If you restart the Controller without saving after a reset, the previous settings will be loaded.\\ \\ | ||
+ | **Erase data storage** — This function may be needed for the correct firmware update, rollback to default settings, in a situation where user actions lead to incorrect operation of the Controller. If the controller has stopped saving the settings, do a reset, wait 3 seconds, and try to save again.\\ \\ | ||
+ | **Update firmware** — starting the firmware update process. You can download the current firmware version and read the rules of update in the **[[en: | ||
===== Control modes ===== | ===== Control modes ===== | ||
Line 428: | Line 442: | ||
The **Controller** > **Motor Setup** menu contains all settings related to electric motor operation parameters. | The **Controller** > **Motor Setup** menu contains all settings related to electric motor operation parameters. | ||
+ | ==== Motor temperature sensor ==== | ||
+ | |||
+ | In the menu section **Controller** > **Motor setup** > **Motor t°-sensor** you can select a temperature range in which a smooth power limit will occur (**Delta °t** parameter) and specify the maximum temperature (**°t max**). | ||
+ | |||
+ | {{: | ||
+ | |||
+ | **°t max** — maximum electric motor temperature, | ||
+ | **Delta °t** — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning of the power limit, in degrees Celsius (°C). Select of values from **1°C** to **100°C**, in increments of **1 °C**. \\ | ||
+ | |||
+ | In the menu item **Sensor type** you can select the following types of temperature sensors that support the controller — **KTY81(82)**, | ||
+ | |||
+ | It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors and select the one that displays data the most closely to room temperature. The current measured temperature is displayed at **# Value °t #**. \\ | ||
+ | |||
+ | The **# °t R (+-10%)#** menu item displays the resistance of the motor temperature sensor, with an accuracy of +/-10%. | ||
==== Clutch ==== | ==== Clutch ==== | ||
Line 828: | Line 856: | ||
**Speed lim. at 0% throttle** | **Speed lim. at 0% throttle** | ||
+ | ===== Motor setup ===== | ||
+ | |||
+ | The **Controller** | ||
==== Motor temperature sensor ==== | ==== Motor temperature sensor ==== |