Line 54: Line 54:
 ~~CL~~ \\ ~~CL~~ \\
 ==== Inputs configuration ==== ==== Inputs configuration ====
-The functions of inputs **I1-I6 **  (see diagram above) are selected in the **Function setup**  section. Two temperature sensors can be connected to uLight. \\+The functions of inputs **I1-I6 **  (see diagram above) are selected in the **Function setup**  section. Two thermal sensors can be connected to uLight. \\
      
 {{:en:ulight_2en.jpg?nolink&241x142 |}} {{:en:ulight_2en.jpg?nolink&241x142 |}}
-**T-sensor T1 type** — selection of **NTC10K3950**  or **NTC10K3380**  temperature sensor. Select **Off**  if no sensor is connected. \\ +**T-sensor T1 type** — selection of **NTC10K3950**  or **NTC10K3380**  thermal sensor. Select **Off**  if no sensor is connected. \\ 
 **# T-sensor T1** — current temperature of the thermal sensor Т1 in degrees Celsius (°C). \\ **# T-sensor T1** — current temperature of the thermal sensor Т1 in degrees Celsius (°C). \\
 **T1 Threshold (port I7)** — I7 is a virtual port intended to function setup (see Function setup). Values ​​from 0°C to 250°C, in 1°C increments. \\ **T1 Threshold (port I7)** — I7 is a virtual port intended to function setup (see Function setup). Values ​​from 0°C to 250°C, in 1°C increments. \\
-**Т1 Threshold mode** — signal operation mode from the temperature sensor, selection of values ​​**Normal** (the signal state is first “off” when triggered is “on”) and **Inverted** (the signal state is first “on”, when triggered is “off”). \\+**Т1 Threshold mode** — signal operation mode from the thermal sensor, selection of values ​​**Normal** (the signal state is first “off” when triggered is “on”) and **Inverted** (the signal state is first “on”, when triggered is “off”). \\
 The settings for Temperature sensor T2 are similar to those for Temperature sensor T1. \\ The settings for Temperature sensor T2 are similar to those for Temperature sensor T1. \\
 **CAN-Control** — this setting refers to the **THR**  (throttle), **BRK**  (brakes), **IO2**, and **IO3**  inputs on the uLight board and is used when the throttle, brakes and switches are connected directly to the uLight board. When you select the **On**  setting, control signals from the inputs will be transmitted via the CAN bus and you will be able to control the Controller from the uLight board using the throttle, brake and switch inputs. \\ **CAN-Control** — this setting refers to the **THR**  (throttle), **BRK**  (brakes), **IO2**, and **IO3**  inputs on the uLight board and is used when the throttle, brakes and switches are connected directly to the uLight board. When you select the **On**  setting, control signals from the inputs will be transmitted via the CAN bus and you will be able to control the Controller from the uLight board using the throttle, brake and switch inputs. \\