meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
en:ulight [2022/04/18 10:11]
dmitry [Inputs configuration]
en:ulight [2022/04/18 10:15]
dmitry [Function setup]
Line 54: Line 54:
 ~~CL~~ \\ ~~CL~~ \\
 ==== Inputs configuration ==== ==== Inputs configuration ====
-The functions of inputs **I1-I6 **  (see diagram above) are selected in the **Function setup**  section. Two temperature sensors can be connected to uLight. \\+The functions of inputs **I1-I6 **  (see diagram above) are selected in the **Function setup**  section. Two thermal sensors can be connected to uLight. \\
      
 {{:en:ulight_2en.jpg?nolink&241x142 |}} {{:en:ulight_2en.jpg?nolink&241x142 |}}
-**T-sensor T1 type** — selection of **NTC10K3950**  or **NTC10K3380**  temperature sensor. Select **Off**  if no sensor is connected. \\ +**T-sensor T1 type** — selection of **NTC10K3950**  or **NTC10K3380**  thermal sensor. Select **Off**  if no sensor is connected. \\ 
 **# T-sensor T1** — current temperature of the thermal sensor Т1 in degrees Celsius (°C). \\ **# T-sensor T1** — current temperature of the thermal sensor Т1 in degrees Celsius (°C). \\
 **T1 Threshold (port I7)** — I7 is a virtual port intended to function setup (see Function setup). Values ​​from 0°C to 250°C, in 1°C increments. \\ **T1 Threshold (port I7)** — I7 is a virtual port intended to function setup (see Function setup). Values ​​from 0°C to 250°C, in 1°C increments. \\
-**Т1 Threshold mode** — signal operation mode from the temperature sensor, selection of values ​​**Normal** (the signal state is first “off” when triggered is “on”) and **Inverted** (the signal state is first “on”, when triggered is “off”). \\+**Т1 Threshold mode** — signal operation mode from the thermal sensor, selection of values ​​**Normal** (the signal state is first “off” when triggered is “on”) and **Inverted** (the signal state is first “on”, when triggered is “off”). \\
 The settings for Temperature sensor T2 are similar to those for Temperature sensor T1. \\ The settings for Temperature sensor T2 are similar to those for Temperature sensor T1. \\
 **CAN-Control** — this setting refers to the **THR**  (throttle), **BRK**  (brakes), **IO2**, and **IO3**  inputs on the uLight board and is used when the throttle, brakes and switches are connected directly to the uLight board. When you select the **On**  setting, control signals from the inputs will be transmitted via the CAN bus and you will be able to control the Controller from the uLight board using the throttle, brake and switch inputs. \\ **CAN-Control** — this setting refers to the **THR**  (throttle), **BRK**  (brakes), **IO2**, and **IO3**  inputs on the uLight board and is used when the throttle, brakes and switches are connected directly to the uLight board. When you select the **On**  setting, control signals from the inputs will be transmitted via the CAN bus and you will be able to control the Controller from the uLight board using the throttle, brake and switch inputs. \\
Line 66: Line 66:
  
 ==== Function setup ==== ==== Function setup ====
-Function setup allows you to select which function each input on the uLight board or CAN input in the Controller or On-board computer corresponds to. All settings in this section of the menu have the same selection of functions: \\ **Off **— disabled. \\ **On**  — enabled. If the lights are connected, they will light constantly. \\ **I1-I6**  — select the number of the input on the uLight board to which the switchch for turning on the lights is connected. You can check the operation of the button in the menu section **Inputs values**, items **Input I1-Input I6**, when the button is turned on, the values ​​will change to **On**. \\ **C1-C16**  — selection of the CAN input number when controlling via the CAN bus. It is used when [[:en:display:start#display_buttons_setup|connecting]] external control buttons to the On-board computer or when using the On-board computer buttons (Hot key). **C1-C16**  are software values, there are fewer physical inputs on the boards, currently, eight CAN ports **IO1-IO8**  are available on the On-board computer (see [[https://drive.google.com/file/d/1KkEgWcJ5U-AEkk6GrXhDNlYXFCcsjpUQ/view|diagram]]).+Function setup allows you to select which function each input on the uLight board or CAN input in the Controller or On-board computer corresponds to. All settings in this section of the menu have the same selection of functions: \\  
 +**Off **— disabled. \\  
 +**On**  — enabled. If the lights are connected, they will light constantly. \\  
 +**I1-I6**  — select the number of the input on the uLight board to which the switchch for turning on the lights is connected. You can check the operation of the button in the menu section **Inputs values**, items **Input I1-Input I6**, when the button is turned on, the values ​​will change to **On**. \\  
 +**I7_T1** and **I8_T2** — selection of the virtual port of the temperature sensor T1 and T2. 
 +**C1-C16**  — selection of the CAN input number when controlling via the CAN bus. It is used when [[:en:display:start#display_buttons_setup|connecting]] external control buttons to the On-board computer or when using the On-board computer buttons (Hot key). **C1-C16**  are software values, there are fewer physical inputs on the boards, currently, eight CAN ports **IO1-IO8**  are available on the On-board computer (see [[https://drive.google.com/file/d/1KkEgWcJ5U-AEkk6GrXhDNlYXFCcsjpUQ/view|diagram]]).
  
 {{:en:output_config.png?nolink&  }} {{:en:output_config.png?nolink&  }}