en:controller:setup [2023/09/30 14:57] dmitry |
en:controller:setup [2023/10/02 06:26] vasilisk |
||
---|---|---|---|
Line 578: | Line 578: | ||
In the **Controller** | In the **Controller** | ||
- | |||
- | {{: | ||
**#Quick voltage setup** — feature to help you select the correct parameters for your battery. To automatically configure the items **Full charge**, **Supply max**, **Supply min**, you need to select the type of battery chemistry from the following options:\\ | **#Quick voltage setup** — feature to help you select the correct parameters for your battery. To automatically configure the items **Full charge**, **Supply max**, **Supply min**, you need to select the type of battery chemistry from the following options:\\ | ||
- | **LiIon (3.6V)** for li-ion battery\\ | + | **LiIon (3.6V)** for li-ion battery.\\ |
- | **LFP (3.2V)** for lithium-iron-phosphate battery (LiFePO4)\\ | + | **LFP (3.2V)** for lithium-iron-phosphate battery (LiFePO4).\\ |
- | **LTO (2.3V)** for lithium-titanate battery (Li4Ti5O12)\\ | + | **LTO (2.3V)** for lithium-titanate battery (Li4Ti5O12).\\ |
Next, select the **Cell count**, values from **8S** to **28S**, in increments of **1S**. After that, in the **Apply setup** item, select **Yes**. After saving the settings, you will see a window with new battery parameters. It is important to remember that we guarantee the operation of controllers with voltages up to 90V. The device is technically rated for 95V, but operating above 90V will void the warranty and you will be warned about this in a pop-up window. For example, if you try to select 22S for a lithium-ion battery. If the settings exceed 95V, the controller will also warn you that you are trying to set the voltage too high.\\ | Next, select the **Cell count**, values from **8S** to **28S**, in increments of **1S**. After that, in the **Apply setup** item, select **Yes**. After saving the settings, you will see a window with new battery parameters. It is important to remember that we guarantee the operation of controllers with voltages up to 90V. The device is technically rated for 95V, but operating above 90V will void the warranty and you will be warned about this in a pop-up window. For example, if you try to select 22S for a lithium-ion battery. If the settings exceed 95V, the controller will also warn you that you are trying to set the voltage too high.\\ | ||
Line 810: | Line 808: | ||
| | ||
**12V protection** | **12V protection** | ||
- | | + | |
+ | **12V protection** | ||
| | ||
| |