~~Title: Controller setup~~ | ~~Title: Controller setup~~ | ||
- | ====== Important! ====== | + | ====== Controller (v.0.8.13) ====== |
- | + | ||
- | Before reading the instructions, | + | |
- | * [[en: | + | |
- | * [[en: | + | |
- | + | ||
- | + | ||
- | ====== Controller (v.0.7) ====== | + | |
The controller allows you to control BLDC (Brushless Direct Current Motor) and PMSM (Permanent Magnet Synchronous Motor) electric motors. At the moment we are producing three types of controllers for different motors power. | The controller allows you to control BLDC (Brushless Direct Current Motor) and PMSM (Permanent Magnet Synchronous Motor) electric motors. At the moment we are producing three types of controllers for different motors power. | ||
Line 14: | Line 7: | ||
//Technical specifications of controllers:// | //Technical specifications of controllers:// | ||
- | ^ Parameters | + | ^ Parameters |
- | ^Maximum power| | + | ^Maximum power| |
^Nominal power| | ^Nominal power| | ||
- | ^Voltage range| | + | ^Voltage range| |
^Phase current, max| 120A | 250А | 500А | | ^Phase current, max| 120A | 250А | 500А | | ||
- | ^Battery current, max| | + | ^Battery current, max| 90A | 150A | |
^Supply out| 12В 3A ||| | ^Supply out| 12В 3A ||| | ||
^Operating temperature range| | ^Operating temperature range| | ||
- | ^Phase wires| | + | ^Phase wires| |
- | ^Battery wires| | + | ^Battery wires| |
- | ^Hall connectors| | + | ^Hall connectors| |
- | ^Wires length| | + | ^Wires length| |
- | ^Control modes| | + | ^Control modes| |
- | ^Protection| | + | ^Protection| |
- | ^Sleep current less| < | + | ^Protection class| |
- | ^Protection class| | + | ^Size, without wires| |
- | ^Size, without wires| | + | ^Weight| |
- | ^Weight| | + | ^Warranty| |
- | ^Warranty| | + | |
//In the kit: // | //In the kit: // | ||
- | | + | * CAN-cable 1,2-meters length for connection to the On-board Computer. |
- | * Phase wires.\\ | + | * Phase wires. |
- | * Battery wires\\ | + | * Battery wires |
* Hall sensors wire. | * Hall sensors wire. | ||
Line 45: | Line 37: | ||
// | // | ||
- | * САN-cables 0,3 and 2 meters length.\\ | + | * САN-cables 0,3 and 2 meters length. |
- | * Controller-side inputs for connection throttle, brakes levers directly to the Controller.\\ | + | * Controller-side inputs for connection throttle, brakes levers directly to the Controller. |
- | * PWM/PAS wire for connection PAS, fans for cooling or brake lights.\\ | + | * PWM/PAS wire for connection PAS, fans for cooling or brake lights. |
===== Connection diagram ===== | ===== Connection diagram ===== | ||
Line 53: | Line 45: | ||
First, connect the three phases of the electric motor. It does not matter in which order and by which color you connect the phases, the controller will automatically detect them during auto-setup. Next, connect the hall connector as shown in the diagram below. You also need to connect the throttle lever and battery power. We also recommend connecting the brake levers, as their actuation turns off the motor. A simple rule — in any incomprehensible situation, press the brake. | First, connect the three phases of the electric motor. It does not matter in which order and by which color you connect the phases, the controller will automatically detect them during auto-setup. Next, connect the hall connector as shown in the diagram below. You also need to connect the throttle lever and battery power. We also recommend connecting the brake levers, as their actuation turns off the motor. A simple rule — in any incomprehensible situation, press the brake. | ||
- | When the power is turned on for the first time, the controller will start automatically. To enable/ | + | When the power is turned on for the first time, the controller will start automatically. To enable/ |
- | You can find the wiring diagrams | + | You can find the wiring diagrams |
- | If you want to connect peripherals directly to the Controller, you need to order " | + | If you want to connect peripherals directly to the Controller, you need to order " |
+ | {{: | ||
- | {{: | + | ~~CL~~ |
- | ~~CL~~ | + | |
===== Connecting multiple controllers ===== | ===== Connecting multiple controllers ===== | ||
- | If you want to connect two or more Controllers, | + | If you want to connect two or more Controllers, |
- | + | ||
- | For example, for a two-motor connection scheme, which is used on all-wheel-drive electric scooters, in addition to the second controller, you will need a CAN-splitter and one more CAN wire (there are 2, 1.2, and 0.3 meters long). Each Controller has a standard CAN-wire 1.2 m long. These wires from both controllers must be connected to a CAN-splitter, | + | |
- | <WRAP center round important 60%>\\ | + | For example, for a two-motor |
- | Pay attention to the connection | + | |
- | First connect | + | |
- | </ | + | |
- | {{:en:controller: | + | <WRAP center round important 60%> \\ Pay attention to the connection diagram. ** Do not disconnect power grounds when system wires are connected! ** First connect all power wires and only then CAN wires. When disconnecting the controllers, |
+ | {{: | ||
====== How to start? ====== | ====== How to start? ====== | ||
- | After you have connected the Controller and Controls according to the diagram, you need to configure the battery parameters. For this, go to the **Settings** > **Devices** section, select the Controller in the list of devices, then go to the **Controller** > **Battery** section and specify the supply voltage range. For a detailed description, | + | After you have connected the Controller and Controls according to the diagram, you need to configure the battery parameters. For this, go to the **Settings** |
- | {{: | + | {{: |
- | After configuring the battery, you need to run Auto-setup in the **Controller** > **Auto-setup** menu section. Ensure that the phase and battery wires are well contacted and insulated before running auto-setup. Check that the Hall sensor wire connectors are fully inserted into the mating parts. For details, see the section **Auto-setup**. After auto-setup, you need to adjust the speedometer to display the speed correctly, see the section [[en: | + | After configuring the battery, you need to run Auto-setup in the **Controller** |
====== Menu navigation ====== | ====== Menu navigation ====== | ||
- | Use the On-board computer buttons to navigate through the menus. Left button — return to the previous menu or cancel editing. Right button — go to the menu section and confirm the parameter selection. The two middle buttons — to move up/down through the menu and select the value of the menu item.\\ | + | Use the On-board computer buttons to navigate through the menus. Left button — return to the previous menu or cancel editing. Right button — go to the menu section and confirm the parameter selection. The two middle buttons — to move up/down through the menu and select the value of the menu item. |
===== Settings saving ===== | ===== Settings saving ===== | ||
- | In the menu item **Controller** > **Save settings** you can save all the settings made. Press the right button of the Onboard-computer and select **On** to save. If you do not save the settings, they will be reset after restart. | + | In the menu item **Controller** |
===== Auto-setup ===== | ===== Auto-setup ===== | ||
- | The auto-setup function in the **Controller** > **Auto-setup** menu section allows you to automatically set up the electric motor, throttle, and brake levers. | + | The auto-setup function in the **Controller** |
- | {{: | + | {{: |
- | The auto-setup menu starts the subprogram and shows only the process. All settings are saved under **Controller** > **Motor setup**. After restarting the Controller, all switches will be in the **Off** position. | + | The auto-setup menu starts the subprogram and shows only the process. All settings are saved under **Controller** |
- | Once you have specified the battery supply voltage in the **Controller** > **Battery** section, you can proceed to calibrate the motor and levers in the Auto-setup section. | + | Once you have specified the battery supply voltage in the **Controller** |
- | Before auto-setup the angles, we recommend specifying the correct number of motor pole pairs in menu item **Controller** > **Auto-setup** > **Pole pairs**. See **[[[: | + | Before auto-setup the angles, we recommend specifying the correct number of motor pole pairs in menu item **Controller** |
- | \\ | + | |
- | <WRAP center round important 60%>\\ | + | |
- | **Be careful! Before running autotuning, check that the drive wheels of your e-bike are not touching the surface and that the pedals (if equipped) do not touch anything when spinning. When adjusting the Hall sensors, the motor rotates in both directions, be careful and do not stand near the bicycle pedals. The motor will rotate five times, once when the motor is detected and four times when correcting the angle.** | + | |
- | </ | + | |
If you have a throttle lever and an analog brake connected, then you need to enable Full Setup, and follow the instructions on the On-Board computer screen. The corresponding menu items will indicate when to press and release the throttle or brake lever. | If you have a throttle lever and an analog brake connected, then you need to enable Full Setup, and follow the instructions on the On-Board computer screen. The corresponding menu items will indicate when to press and release the throttle or brake lever. | ||
- | If only one throttle lever is connected, you must independently turn on the items step-by-step: | + | If only one throttle lever is connected, you must independently turn on the items step-by-step: |
- | If the motor is heavy and autodetect does not happen, you can gently push it with your hand or increase the tuning current in the **Controller** > **Auto-setup** > **Setup current** section, for example, twice. The setup current can be selected in the range from **2A** to **50A**, in increments of **1A**. | + | If the motor is heavy and autodetect does not happen, you can gently push it with your hand or increase the tuning current in the **Controller** |
- | If the motor is rotating in the wrong direction, go to **Controller** > **Auto-setup** > **Spin direction** and change the direction of rotation. You can choose from two options **Forward** or **Invert**. A similar setting is available in the **Controller** > **Motor setup**> **Spin direction** menu. It doesn' | + | If the motor is rotating in the wrong direction, go to **Controller** |
- | If an error occurs during autotuning, see the section **[[en: | + | If an error occurs during autotuning, see the section **[[:en: |
===== Firmware update ===== | ===== Firmware update ===== | ||
- | In the menu section **Controller** > **Settings and Update**, you can update the Controller' | + | In the menu section **Controller** |
- | {{: | + | {{: |
- | **Import config.** — loads the settings from the file ** NCconf.cfg ** - ** NCconf9.cfg ** up to a maximum of 9 different configurations, | + | **Import config.** |
- | **Export config.** - saves the settings to the ** NCconf.cfg ** - ** NCconf9.cfg ** file up to a maximum of 9 different configurations, | + | |
- | **Reboot** — restarts the device. If the settings have not been saved, they will be reset.\\ \\ | + | |
- | **Reset Wh usage** — resets the accumulated number of Watt-Hours in the controller. This indicator is displayed in the statistics of the On-board computer, see section **[[en: | + | |
- | **Reset stats** — resets mileage in kilometers.\\ \\ | + | |
- | **Load defaults** — after a reset, the default settings are loaded but not saved. If you restart the Controller without saving after a reset, the previous settings will be loaded.\\ \\ | + | |
- | **Erase data storage** — This function may be needed for the correct firmware update, rollback to default settings, in a situation where user actions lead to incorrect operation of the Controller. If the controller has stopped saving the settings, do a reset, wait 3 seconds, and try to save again.\\ \\ | + | |
- | **Update firmware** — starting the firmware update process. You can download the current firmware version and read the rules of update in the **[[en: | + | |
===== Control modes ===== | ===== Control modes ===== | ||
- | In the menu section **Controller** > **Control modes** you can configure and save three presets of the parameters of the electric motor and switch between them using a 3-position switch or buttons on the On-board computer. The currently active mode number is displayed at the top of the main screen. After setting, it is necessary to activate the modes in the menu item **Controller** > **Additional modes** > **Enable additional modes** by setting the value **On**. In the same menu **Controller** > **Additional modes** you can make detailed settings for each mode (see the section Additional modes). | + | In the menu section **Controller** |
- | If there is no speed switch, then mode 1 is the default. If the switch is connected to the On-board computer, it is necessary to configure the On-board computer buttons in the **On-board computer** > **Button settings** menu. See section **[[en: | + | If there is no speed switch, then mode 1 is the default. If the switch is connected to the On-board computer, it is necessary to configure the On-board computer buttons in the **On-board computer** |
==== Modes setup ==== | ==== Modes setup ==== | ||
- | {{: | + | {{: |
- | The ** # Current mode ** line displays the currently selected control mode. List of possible options: \\ | + | The ** # Current mode ** line displays the currently selected control mode. List of possible options: \\ **N** — neutral. \\ **S1** |
- | **N** — neutral. \\ | + | |
- | **S1** — speed 1. \\ | + | |
- | **S2** — speed 2. \\ | + | |
- | **S3** — speed 3. \\ | + | |
- | **RV** — reverse. | + | |
- | Four parameters are used to configure each mode: \\ | + | Four parameters are used to configure each mode: \\ **Phase** |
- | **Phase** — the maximum value of the phase current, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. When setting, consider the maximum phase current of your controller type. In most cases, we recommend specifying the value of the phase current 1.5-2 times higher than the battery current.\\ | + | |
- | **Battery** — the maximum value of the battery current, in Amperes (**A**). Select of values from **2A** to **400A**, in increments of **2A**. When setting up, consider the capabilities of the connected battery and the maximum battery current of your controller type.\\ | + | **Battery** |
- | **Power** — maximum power (discharge) of the battery, in kilowatts (**kW**). Select of values from **0.00kW** to **30.0kW**, in increments of **0.1kW**. Set to 0.0kW to disable the power limiting limit.\\ | + | **Power** |
- | **Speed** — maximum speed in percentage (%). Select of values from **4%** to **150%**, in increments of **2%**. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en: | + | **Speed** |
==== Electric brake setup ==== | ==== Electric brake setup ==== | ||
- | **Braking phase** — the value of the phase current of braking by the motor, in Amperes (**A**). Select of values from **0A** to **500A**, in increments of **2A**. For braking to zero, it is recommended to enable **Active braking** in the section **Controller** > **Control**. When using the switch brake, lower brake current change speed makes recuperation more smooth. | + | **Braking phase** |
==== Braking phase at speed control ==== | ==== Braking phase at speed control ==== | ||
- | **Braking ph. at speed** — phase braking current during speed control, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows you to slow down when you reset the throttle stick. Works only with Direct Drive motors, without a clutch. | + | **Braking ph. at speed** |
- | Also to use this mode should be selected: | + | Also to use this mode should be selected: **Speed** |
- | **Speed** or **Speed and Torque** mode in the **Controller** > **Control** > **Throttle Mode** menu item. | + | |
- | In the menu item **Controller** > **Control** > **Speed lim. at 0% throttle** enable the speed limit at 0% throttle (optional), enable if you need braking with completely released throttle. | + | |
- | ==== Reverse setup ==== | + | ==== Regenerative braking setting |
- | **Speed reverse** — reverse speed, in percentage | + | **Braking ph. at 0% throttle** — phase braking current with the throttle handle released, in Amperes |
- | **Phase reverse** — the value of the reverse phase current, in Amperes (**A**). Select of values from **10A** to **500A**, in increments of **2A**.\\ | + | This function will be active if additional modes are disabled in the **Controller** > **Advanced modes** |
+ | ==== Reverse setup ==== | ||
- | ==== Field weakening setup ==== | + | **Speed reverse** |
- | **Field weakening** — the magnitude | + | **Phase reverse** — the value of the reverse phase current, in Amperes (**A**). Select of values from **10A** to **500A**, in increments of **2A**. |
- | <WRAP center round info 60%>\\ | + | ==== Field weakening setup ==== |
- | The current of weakening creates a field that acts against the field of the permanent magnets. The superposition of these fields creates an equivalent field that is below nominal. The attenuation efficiency depends on the parameters of the motor. The best results can be obtained with IPM motors. | + | |
- | </ | + | **Field weakening** |
To set up the weakening, you need: | To set up the weakening, you need: | ||
- | * for one of the control modes in the section **Controller** > **Control modes** specify a speed value greater than 100%, for example, Speed 3 is 120%. | ||
- | * set the weakening current value in the section **Controller** > **Control modes**, you can start from 30A.\\ | ||
- | Field weakening is activated when the maximum speed is reached, | + | * for one of the control modes in the section **Controller** > **Control modes** |
+ | * set the weakening current | ||
- | Also, the Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery). If the motor starts twitching on the suspended wheel, then it is necessary to reduce the weakening current.\\ | + | Field weakening is activated when the maximum speed is reached, the Controller adds weakening current, limiting the phase current and weakening current specified in the control mode. That is if the effective phase current is 70A, and the weakening current is set to 30A, then a minimum of 100A must be specified in the phase current settings. If the phase current increases to 80A, then only 20A will remain for weakening because 80A 20A = 100A. |
+ | |||
+ | Also, the Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery). If the motor starts twitching on the suspended wheel, then it is necessary to reduce the weakening current. | ||
==== Current change speed ==== | ==== Current change speed ==== | ||
- | **# Current change speed**. | + | **# Current change speed**. |
- | * acceleration, | + | |
- | * braking, select of values from **50A/s** to **50000A/ | + | * acceleration, |
- | * shutdown, select of values from **50A/s** to **50000A/ | + | * braking, select of values from **50A/ |
+ | * shutdown, select of values from **50A/ | ||
- | Three parameters determine the rate of change of the current (smoothness). The higher the value, the faster the current build-up in the motor will occur. For conventional brake levers, it will be useful to reduce the parameter **braking** for a smoother activation of the regeneration. If the throttle response seems too slow, you need to increase the parameter **acceleration**. The parameter **shutdown** determines how quickly the current drops after throttle and brakes are released. | + | Three parameters determine the rate of change of the current (smoothness). The higher the value, the faster the current build-up in the motor will occur. For conventional brake levers, it will be useful to reduce the parameter **braking** |
===== Advanced control modes ===== | ===== Advanced control modes ===== | ||
- | In the menu section **Controller** > **Advanced modes** enables the control modes and activates the advanced settings for each of these modes.\\ | + | In the menu section **Controller** |
- | {{: | + | {{: |
- | To activate the control modes, select **Controller** > **Advanced modes** > **Enable add. modes** and to set **On**. | + | To activate the control modes, select **Controller** |
- | In the menu **Controller** > **Advanced modes** > **Neutral by default** you can activate the neutral mode (N) when the controller starts up, which will be active until one of the speed modes is activated. In a neutral mode, only the electric brake operates, throttle and PAS are disabled. This mode is recommended for use with speed buttons (not a switch). The function does not work with a 3-position switch (functions of the S1of3 and S3of3 ports in the **Controller** > **I/O configuration** menu). \\ | + | In the menu **Controller** |
- | Each mode has its own section in the **Controller** > **Advanced modes** > **Mode S1, Mode S2, Mode S3 ** with the following settings: \\ | + | **Neutral timer** — switches neutral on after a certain time in seconds (**s**), which is set in the settings. To turn it off, switch |
- | {{: | + | ~~CL~~ |
- | **Throttle mode** — selection of the operating mode of the throttle lever, read more in the section **[[en: | + | |
- | **Acceleration lim.** and **Deceleration lim.** — are specified | + | Each mode has its own section |
- | **Revers** — reverse gear activation when the control | + | {{: |
- | **Cruise** — activation of the cruise function. Select | + | **Acceleration lim.** and **Deceleration lim.** — are specified in ERPM/s, select |
- | **Disable motor** — completely disables | + | **Braking phase** — the value of the phase current of braking by the motor, in Amperes (A). Select of values |
- | **Disable | + | **Braking ph. at 0% throttle** |
- | **Active braking** — allow the brake to use the battery for stopping. Select of values **On** or **Off**. | + | **Revers** — reverse gear activation when the control mode is selected. Select of values **On** |
- | **Reverse on brake** — after stopping, pressing | + | **Cruise** — activation of the cruise function. Select of values **On** |
- | **Speed lim. at 0% throttle** — allows limiting the speed when the throttle lever is released. Select of values **On** or **Off**. | + | **Disable motor** — completely disables motor control. Select of values **On** |
- | **Disable | + | **Disable |
- | **PAS Scale** — extra PAS multiplier | + | **Active braking** — allow the brake to use the battery |
- | ===== Control ====== | + | **Reverse on brake** |
- | In the **Controller** > **Control** menu section you can setup setting the engine controls, throttle levers, torque and PAS sensors, cruise control. | + | |
+ | **Speed lim. at 0% throttle** | ||
+ | |||
+ | **Disable PAS** — disables the Pedal Assist. Select of values **On** | ||
+ | |||
+ | **PAS Scale** | ||
+ | |||
+ | ===== Control ===== | ||
+ | |||
+ | In the **Controller** | ||
==== PAS and Torque sensor setup ==== | ==== PAS and Torque sensor setup ==== | ||
- | In the menu section **Controller** > **Control** > **Pedal Assist System** you can set up the Pedal Assist System (PAS), which connects the electric motor when pedaling. | + | In the menu section **Controller** |
- | ЧTo be able to connect the PAS system, it is necessary to order the PWM IO/PAS cable as an option. The PAS system connects to the Controller via the PWM IO/PAS wire to the **P1/P2** ports of the **USB/PWM** connector. When using a SEMPU pressure sensor, an additional signal output from the TH port of the connector **Control** is required. | + | To be able to connect the PAS system, it is necessary to order the PWM IO/PAS cable as an option. The PAS system connects to the Controller via the PWM IO/PAS wire to the **P1/ |
- | You can look at the connecting methods of various PAS systems at **[[en: | + | You can look at the connecting methods of various PAS systems at **[[:en: |
- | The PAS, unlike the Torque sensor, controls the throttle by frequency and not by the force of rotation. The PAS setup menu consists of the following items: | + | The PAS, unlike the Torque sensor, controls the throttle by frequency and not by the force of rotation. The PAS setup menu consists of the following items: |
- | {{: | + | {{: |
- | **PAS** — selection of pedaling assistant type **PAS sensor** or **Torque sensor**. If there is no PAS system, select **Disabled**.\\ | + | |
- | **PAS connection** — 1-wire or 2-wire connection option, two wires are used for the angle sensor (encoder). \\ | + | **PAS** |
- | **Invert | + | |
- | **PAS poles** — number of impulses per pedal revolution. Select of values from **1** to **200**, in increments of **1**.\\ | + | |
- | **PAS min. freq.** — the minimum pedal speed (cadence) at which the motor starts, RPM. Select of values from **1 RPM** to **500 RPM**, in increments of **1 RPM**. \\ | + | |
- | **PAS max freq.** — the maximum pedal speed (cadence) at which the motor starts, RPM. Select of values from **10 RPM** to **1000 RPM**, in increments of **5 RPM**. \\ | + | |
- | **# PAS freq.** — the value of the signal coming from the PAS in real-time. \\ | + | **PAS connection** — 1-wire or 2-wire connection option, two wires are used for the angle sensor (encoder). \\ **Invert |
- | **PAS timeout** — the time after which the motor turns off after stopping pedaling, | + | |
- | **PAS filter** — smoothing the control signal for smoother operation, in hertz (Hz). Select of values from **1 Hz** to **100 Hz**, in increments of **1 Hz**. \\ | + | |
- | **PAS min out** — minimum | + | |
- | **PAS max out** — maximum | + | |
- | Further | + | **# PAS freq.** |
- | **Pressure scale** — in Newton-meters/ | + | Further |
- | **Zero pressure** — zero pressure, in millivolts (mV). Select of values from **0mV** to **10000mV**, | + | |
- | | + | |
- | **Torque | + | |
- | **# Torque** — shows the current | + | **Pressure scale** — in Newton-meters/ |
- | **# Human watt** — shows the average power you develop when pedaling, in watts (W). \\ | + | **# Torque** — shows the current torque at the sensor, in Newton meters |
- | **Human watt min** — the minimum power you develop to activate the motor, in watts (W). Select of values from **0 W** to **500 W**, in increments of **10 W**. \\ | + | |
- | **Human watt max** — the maximum power for 100% activation, in watts (W). Select of values from **0 W** to **1000 W**, in increments of **10 W**. \\ | + | |
- | **Torque | + | **# Human watt** |
- | **Torque max** — the torque, which limits the level of 100% throttle, Newton-meters (Nm). Select of values from **0 Nm** to **300 Nm**, in increments of **2 Nm**. \\ | + | |
- | **Instant Torque** — allows torque sensor activation without rotation. Select of values **On** or **Off**. The pressure sensor also includes frequency configuration and output level configuration as well as the usual PAS. | + | **Torque min** — the torque at which the throttle signal starts to increase, Newton-meters (Nm). Select of values from **0 Nm** to **100 Nm**, in increments of **2 Nm**. All values less than this level is 0% of throttle. \\ **Torque max** — the torque, which limits the level of 100% throttle, Newton-meters (Nm). Select of values from **0 Nm** to **300 Nm**, in increments of **2 Nm**. \\ **Instant Torque** |
==== Remote control ==== | ==== Remote control ==== | ||
- | The **Controller** > **Control** > **RC Control** menu section allows you to configure the remote control of the Controller using an external RC receiver. | + | The **Controller** |
+ | |||
+ | {{: | ||
+ | |||
+ | Input for radio control via PWM (PWM), connects to the **P1** | ||
+ | |||
+ | The **# Input Freq.** | ||
- | {{: | + | In the menu item **Function** |
- | Input for radio control via PWM (PWM), connects to the **P1** port of the **USB/PWM** connector on the Controller board. To activate the function, select the **PWM** value in the **P1 Input Mode** menu item. \\ | + | ~~CL~~ |
- | The **# Input Freq.** | + | \\ Adjust the throttle |
- | In the menu item **Function** selects the control function — **Off**, **Throttle**, **Brake** or **Throttle and brk**. \\ | + | **# Throttle range** \\ **Throttle min** — minimum throttle value, in milliseconds (ms). Select of values from **0.00 ms** |
- | ~~CL~~ \\ | + | |
- | Adjust the throttle | + | |
- | **# Throttle range** \\ | + | **# Brake range** \\ **Brake min** — minimum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ **Brake max** — maximum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. |
- | **Throttle min** — minimum throttle value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ | + | |
- | **Throttle max** — maximum throttle value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ | + | |
- | + | ||
- | **# Brake range** \\ | + | |
- | **Brake min** — minimum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ | + | |
- | **Brake max** — maximum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. | + | |
==== Cruise control setup ==== | ==== Cruise control setup ==== | ||
- | In the menu section **Controller** > **Control** > **Cruise** you can set up the cruise control function. After connecting buttons or switches for cruise control to the ports of the Controller or Onboard Computer, you need to configure the functions that relate to cruise control:\\ | + | In the menu section **Controller** |
- | **CRe** — cruise activation. \\ | + | **CRe** |
- | **CR+** — increase cruise speed (when active). \\ | + | |
- | **CR-** — decrease cruise speed (when active). \\ | + | |
- | **CRr** — restoring cruise (turning on the last saved speed). | + | |
- | For more information about configuring these functions, read the **[[en: | + | For more information about configuring these functions, read the **[[:en: |
- | {{: | + | {{: |
- | In the **Cruise** menu item, you can select several control modes: \\ | + | |
- | **Disabled** — cruise control disabled. \\ | + | |
- | **Button** — activation of cruise control at the push of a button. The response time of the button is determined by the parameter **Cruise EN time**. \\ | + | |
- | **Switch** — activation of cruise control by turning on the switch, time is not used. \\ | + | |
- | **Throttle hold** — activation of cruise control by holding the throttle for a certain time in one position. The response time is determined by the parameter **Cruise EN time**. The accuracy is set by the parameter **Cruise by throttle** in percent (%). Select of values from **1%** to **30%**, in increment of **1%**. Accuracy is essential, as the throttle lever moves slightly during the ride due to shaking. The default is **2%**. \\ | + | |
- | **Allow Throttle hold** — similar to the previous mode, with the difference that to activate the cruise control, you must additionally press the cruise button. | + | |
Next are the menu items for setting the cruise: | Next are the menu items for setting the cruise: | ||
- | **Cruise restore** — this function activates the last saved cruise speed. To enable, select the **CRr** function when configuring **[[en: | + | **Cruise restore** |
- | **Cruise EN time** — setting the cruise activation delay in seconds after enabled button (**s**). Select of values from **0.25s** to **30.00s**, in increments **0.25s**. | + | **Cruise EN time** |
- | **Cruise level** — selects what speed cruise will use: \\ | + | **Cruise level** |
- | * **Throttle** — speed depends on the position of the throttle lever, turns on instantly. \\ | + | |
- | * **Speed** — cruise enables when **Safe acceleration** reached after that uses current speed as a reference. \\ | + | |
- | * **Mixed** — if controller cant use speed reference, uses throttle value. \\ | + | |
- | **Cruise smoothness** — this setting limits acceleration during cruising so that there are no jerks, measured in electrical revolutions per minute per second (ERPM/s). To get the value in rpm, the ERPM/s value must be divided by the number of pole pairs of the electric motor. Select of values from **0 ERPM/s** to **50000 ERPM/s**, in increments of **50 ERPM/ | + | * **Throttle** |
+ | * **Speed** | ||
+ | * **Mixed** | ||
+ | **Cruise smoothness** | ||
- | **# Used for cruise activation**: | + | **# Used for cruise activation**: |
- | **Safe acceleration** — limits the acceleration at which the cruise is activate, for example, to prevent it from engaging when accelerating, | + | |
- | **Min. speed** — speed below which you can not activate cruise or recovery, in kilometers per hour (km/h). Select of values from **3 km/h** to **127 km/h**, in increments of **1 km/h**.\\ | + | |
- | Additionally, | + | Additionally, |
What actions disable cruise control: | What actions disable cruise control: | ||
+ | |||
* pressing the brake, analog or digital. | * pressing the brake, analog or digital. | ||
* repeated throttle press. | * repeated throttle press. | ||
* if a switch is used — when it's disabled. | * if a switch is used — when it's disabled. | ||
* reverse enable. | * reverse enable. | ||
- | |||
==== Throttle and brake curves setup ==== | ==== Throttle and brake curves setup ==== | ||
- | In the menu section **Controller** > **Control** > **Throttle/ | + | In the menu section **Controller** |
- | {{: | + | {{: |
- | You can select the following types of throttle and brake presets: \\ | + | You can select the following types of throttle and brake presets: \\ **Linear** |
- | **Linear** — smooth increase, direct dependence. \\ | + | |
- | **Exponential** — slow increase. \\ | + | |
- | **Normal** — average between linear and exponential. \\ | + | |
- | **Polynomial** — average between normal and exponential. | + | |
- | Manual setting of throttle and brake position points is also available, to do this select **None** in **Throttle preset** or **Brake preset** and enter the value manually. There are eight position points available for throttle and brake:: \\ | + | Manual setting of throttle and brake position points is also available, to do this select **None** |
- | **Start** — starting point, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ | + | |
- | **1**-**6** — midpoints, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ | + | |
- | **End** — end point, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. | + | |
You can also manually edit the value of each point in the loaded preset. | You can also manually edit the value of each point in the loaded preset. | ||
- | ~~CL~~ \\ | ||
- | ==== Control source ==== | ||
- | The controller supports the connection of controls (throttle, brake, switches, and buttons) to the Controller, On-board computer, ulight board, or mixed connection when one part of the periphery is connected to the Controller, and the second part to the On-board computer, or to ulight and On-board computer. This is necessary in the case of Tork/PAS sensor configurations in the Controller + throttle lever in the On-board computer. In the menu item **Controller** > **Control** > **Control Source** you can set up the control source of the Controller`s. \\ | + | ~~CL~~ |
- | {{: | + | ==== Control source ==== |
- | Select | + | The controller supports the connection |
- | **Auto** — all sources will control | + | |
- | **Embedd** — only what is connected directly to the Сontroller. \\ | + | |
- | **Remote** — control only via CAN bus (via On-board computer or Microlight). \\ | + | |
- | **Disabled** — disables any control of the Controller. | + | |
- | ~~CL~~ \\ | + | |
- | ==== Throttle control mode setup ==== | + | {{: |
- | The menu item **Controller** > **Control** > **Throttle modes** you can set up throttle lever mode. | + | Select of control options: \\ **Auto** — all sources will control the Сontroller. Built-in and external, connected via CAN bus (for example, On-board computer or ulight). \\ **Embedd** — only what is connected directly to the Сontroller. \\ **Remote** — control only via CAN bus (via On-board computer or Microlight). \\ **Disabled** |
- | {{: | + | ~~CL~~ |
- | Three throttle modes options are available: | + | ==== Throttle control |
- | **Speed** — a similar | + | |
- | **Torque** — in this mode, the throttle controls phase current, the thrust is limited by the angle of rotation of the throttle. \\ | + | |
- | **Speed+torque** — combined mode (as Kelly), similar to the operation of the gas pedal in a car with an internal combustion engine. \\ | + | |
- | In the case of selecting the **Speed+torque** mode, pressing | + | The menu item **Controller** > **Control** |
- | ==== Throttle and brake voltage range setup ==== | + | |
- | The menu items in the **Controller** > **Control** section allow you to set the voltage ranges of the throttle and brake grips. \\ | + | {{: |
- | {{:en: | + | Five throttle modes options are available: \\ **Speed** |
- | Currently, voltage settings for all throttles and brakes are common. \\ | + | **Adaptive throttle** — this function allows you to more accurately dose throttle |
- | **# Throttle** — shows the voltage of throttle | + | |
- | **Throttle min** and **Throttle max** — range of the throttle grip, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. If the maximum value is exceeded by 5%, protection against a broken throttle grip will be activated. If the range is incorrectly | + | |
- | **# Brake** — shows the voltage | + | ==== Throttle and brake voltage range setup ==== |
- | **Brake min** and **Brake max** — range of the analog brake lever, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. \\ | + | |
- | **Invert brake** — inverts the voltage value from the built-in brake lever. Select **On** to enable. It is useful to enable when the voltage brake lever with reverse voltage is connected to the On-board computer and you want to use the value **Auto** in the menu item **Controller** > **Control** | + | The menu items in the **Controller** |
- | **Active braking** — enables brake to use the battery for stopping. Select | + | |
- | **Brake at overheat** — enables full torque braking when motor overheated. Select of values **On** and **Off**. \\ | + | |
- | **Reverse on brake** — after stopping, pressing the brake lever again activates reverse. Select of values **On** and **Off**. | + | |
- | ==== Setup 100% speed value ==== | + | |
- | The menu items in the **Controller** > **Control** section allow you to adjust the 100% speed level. The maximum speed in the field weakening mode is 150%. | + | {{: |
- | {{:en:controller:k14_en.png?nolink |}} | + | Currently, voltage settings for all throttles and brakes are common. \\ **# Throttle** |
- | **Speed ref. filter** — filter mode selection. Select | + | **# Brake** — shows the voltage |
- | **Filter factor** — sets the filtration factor. Select | + | **Brake button power** — braking force when pressing |
- | **Speed | + | ==== Boost mode ==== |
- | * **OFF** — completely disables speed control PID. \\ | + | |
- | * **Middle U bat** — the average value between the minimum and maximum voltage of the battery settings used as speed reference, depending on motor kV. \\ | + | |
- | * **U supply** — supply voltage used as speed reference, depending on motor kV. \\ | + | |
- | * **Ref. speed** — speed in km/h, is set by parameter **Reference speed**. The speed value is taken from the motor or from an external speed sensor connected to the controller. \\ | + | |
- | * **Ref. ERPM** — speed in motor electric RPM, is set by parameter **Reference speed**. \\ | + | |
- | **Minimum speed** — in electrical revolutions per minute | + | **Boost duration** (User level) — maximum power operation time, in seconds. Select of values from **0.2**s to **10**s, in increments of **0.2**s. The function works as follows: in the **Controller** |
- | **Speed lim. at 0% throttle** — enables limiting | + | For example, on the Sur-Ron Ultra Bee, this mode allows you to squeeze |
- | ===== Motor setup ===== | + | ==== Setup 100% speed value ==== |
- | The **Controller** > **Motor Setup** menu contains all settings related | + | The menu items in the **Controller** |
- | ==== Motor temperature sensor ==== | + | {{: |
- | In the menu section | + | **Speed ref. filter** — filter mode selection. Select of values |
- | {{: | + | **Filter factor** |
- | **°t max** — maximum electric motor temperature, | + | **Speed mode** |
- | **Delta °t** — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning | + | |
- | It is recommended to install a temperature sensor so close as possible | + | * **OFF** |
+ | * **Middle U bat** — the average value between the minimum and maximum voltage of the battery settings used as speed reference, depending | ||
+ | * **U supply** | ||
+ | * **Ref. speed** | ||
+ | * **Ref. ERPM** | ||
+ | **Minimum speed** | ||
- | In the menu item **Sensor type** you can select | + | **Speed lim. at 0% throttle** — enables limiting |
- | ==== Clutch | + | ===== Motor setup ===== |
- | In the menu section | + | The **Controller** |
- | {{: | + | ==== Motor temperature sensor ==== |
- | The parameter | + | In the menu section |
- | **Accelerate** — smoothly accelerates the motor until the load appears. \\ | + | |
- | **Accelerate and hold** — in addition to the previous one, it applies weak torque to the motor after the throttle is released, this mode allows you to switch speeds at mid-drive systems without using the pedals. \\ | + | |
- | **# Phase amps** \\ | + | {{: |
- | **Start time** — maximum time for soft start, in seconds (s). Select values from **1s** to **20s**, in increments of **1s**. \\ | + | |
- | **Start current** — phase motor current at which the load will be detected and the soft start is disabled, in amperes (А). Select values from **0.2А** to **50.0А**, in increments of **0.2А**. This value must be higher than the phase current for specified acceleration of the motor without load. \\ | + | |
- | **Detection time** — the time during which the load must be present, after which the soft start will be switched off, in milliseconds (ms). Select values from **10 ms** to **1000 ms**, in increments of **10 ms**. \\ | + | |
- | **Acceleration** — value in volts/ | + | |
- | **Hold (20%)** and **Hold (80%)** — two parameters regulating the phase current supplied to the motor in the mode **Accelerate and hold**, in amperes (А). **20%** — current at low speeds, **80%** — current at about maximum speed. It is possible to determine the approximate values by the no-load current of the motor. Select values from **0.2А** to **50.0А**, in increments of **0.2А**. \\ | + | |
- | **Hold enable time** — time through which after the throttle has been pressed, torque hold will become available, in seconds (s). Select values from **1s** to **120s**, in increments of **4s**. \\ | + | |
- | **Hold time** — the time during which torque | + | **°t max** — maximum electric motor temperature, |
- | <WRAP center round tip 60%>\\ Optimal settings for MAC motor: | + | In the menu item **Sensor type** |
- | ==== Manual setup the Hall sensors | + | It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors |
- | In general, it is not recommended to change these settings manually!\\ | + | The **# °t resistance** menu item displays |
- | In the menu section | + | |
- | {{: | + | **Resistance Offset** |
- | **Offset for square** — additional shift for square wave mode, in degrees (**°**). Select of values from **-30°** to **30°**, in increments of **1°**. \\ | + | ==== Clutch ==== |
- | **Offset total fwd** — shift all Halls sensors by the specified value for the direct rotation of the motor, in degrees (**°**). Select of values from **-60°** to **60°**, in increments of **1°**. \\ | + | |
- | **Offset total bkwd** — shift all Halls sensors by the specified value for the reverse rotation of the motor., in degrees (**°**). Select of values from **-60°** to **60°**, in increments of **1°**. \\ | + | |
- | To shift all the halls, | + | In the menu section **Controller** |
- | **Reset angles** — reset of all Hall sensors angles. Select of values **On** and **Off**. \\ | + | {{: |
- | **Integration threshold** — analogue of Hall angles for sensorless engine control mode, in volts (**V**). \\ | + | |
- | **Hall adjust Ki** — the meaning of the coefficient is to find the midpoint of the position of the Hall sensors when adjusting them. Values from **0.02** to **5.00**, in increments of **0.02**. If the value of the coefficient is too small, then the tuning process will end before the midpoint is determined. If the value of the coefficient is too large, then the setting will not be completed and will stop by timeout, because the midpoint will not be found due to the angles changing too often. | + | |
- | ==== Hall table ==== | + | The parameter **Mode** |
- | The **Controller** > **Motor Setup** > **Hall table** menu section shows the Hall indices | + | **# Phase amps** \\ **Start time** — maximum time for soft start, in seconds (s). Select values from **1s** to **20s**, in increments of **1s**. \\ **Start current** |
- | {{: | + | **Hold time** |
- | ~~CL~~ \\ | + | |
- | ==== Motor parameters ==== | + | <WRAP center round tip 60%> \\ Optimal settings for MAC motor: **Accelerate**, |
- | Items in the **Controller** > **Motor setup** menu section allow you to configure the parameters of the electric | + | ==== Setup the motor position sensors ==== |
- | {{: | + | Under the menu section **Controller** |
- | **Pole pair** — the number of pole pairs of the stator winding of the electric motor determines the speed at which the motor shaft will rotate. This parameter is used to calculate RPM and speed. For a more accurate autodetection of the Hall sensors angles, you must specify the correct value for the number of pole pairs for your motor. For the most popular motors, you can see this value in the table **[[en:motor_information|Motor Information]]**. If your motor is not listed in the table, check with the manufacturer for the number of pole pairs. \\ | + | {{:en:controller: |
- | **Spin direction** — this setting allows you to change the direction of rotation of the electric motor. Select | + | **Sensor type** — Parameter needs reboot if manually changed. There are currently two types of sensors available: \\ **Hall** — Hall sensors. \\ **Encoder** |
- | **Integration | + | **Sensor mode** |
- | **Control mode now** — the current motor control mode, the parameter switches the real-time control mode, but does not save it. See below for a description of each mode. \\ | + | **Interpolate sensors** — smooth change of the sensors angle based on speed. Used for FOC mode. Select of values **On** |
- | **Control mode** — this parameter | + | **Interpolation start** — the motor is always started from a discrete angle, if digital halls are used. After the specified speed, the angle starts to change smoothly. Select of values from **0 rad/ |
- | | + | **Frequency control** — a separate mode that can be used to power equipment through |
- | * **Square** — outdated control method used only for motor detection. \\ | + | |
- | * **Combined** — start the motor on Hall sensors, then switch to sensorless mode, the threshold is determined by the parameter radians per second (**rad/s**) in the **From hall to s-less** menu item. Select of values from **0.00 rad/s** to **2.00 rad/s** in increments of **0.05 rad/s**. To convert values keep in mind that 1 rad/s to RPM = 9.5493 RPM. \\ | + | |
- | * **FOC** — field-oriented control of the motor. \\ | + | |
- | * **Hz** — 3-phase square with a fixed frequency. \\ | + | |
- | * **Sine | + | |
- | **Interpolate halls** — smooth change of the Hall sensors | + | ==== Hall sensors |
- | **Interpolation start** — the motor is always started from a discrete angle, if digital halls are used. After the specified speed, the angle starts to change smoothly. Select of values from **0 rad/s** to **100 rad/s**, in increments of **1 rad/s**. \\ | + | Further in the menu section |
- | **Frequency control** — a separate mode that can be used to power equipment through a transformer or to dry the varnish on the motor windings. Select of values from **10 HZ** to **200 HZ**, in increments of **1 HZ**. \\ | + | {{: |
- | **Boost square current** — in the sensorless or square mode, applies 100% PWM at the beginning of each winding switch. Starting from specified speed and minimum requested current. Select of values | + | **Hall filter** — enable or disable the filter |
- | **Boost current** — setting refers to the control mode **Square**, the minimum current from which the rapid current pumping | + | **State filter** — select |
- | **Boost speed** — setting refers to the control mode **Square**, the minimum | + | **Min step filter** — minimum |
- | **Max motor U** — limits voltage supplied to the motor, in volts (**V**). In most cases, this parameter is not needed. Select | + | **Direction filter** — select |
- | **kV** — motor parameter, electric revolutions per volt (**eRPM/V**). | + | **Idle filter** — when the motor is not moving, the sensor position is reset to the middle position. Selection of values from **10ms** to **1000ms**, in **5ms** |
- | ===== Battery ===== | + | **Disable pullup** |
- | In the **Controller** > **Battery** | + | The next menu sections shows the Hall indices and Hall angles for the two directions of rotation |
- | {{: | + | ~~CL~~ |
- | **Full charge** — delta voltage relative to the maximum, at which when the controller is turned on, will reset the watt-hour consumption, | + | ==== Manual setup the Hall sensors angles ==== |
- | **Supply max** and **Supply min** — battery voltage range, in volts (**V**). Select values from **20.00V** to **95.00V**, in increments | + | In general, it is not recommended to change these settings manually! \\ In the menu section |
- | For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**. \\ | + | {{: |
- | For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**. \\ | + | |
- | <WRAP center round important 60%> | + | **Offset for square** |
- | We guarantee stable operation | + | |
- | </ | + | |
+ | To shift all the halls, you must press the right button of the On-board computer, enter the shift angle, press the right button again. The value will be reset and the angle of all halls will change to the specified value. You can change the angle of the hall shift in the opposite direction by setting a negative value. | ||
- | **Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes | + | **Reset angles** — reset of all Hall sensors angles. Select of values |
- | **Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** to **400.0А**, | + | ==== Encoder |
- | **Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** to **30000 W**, in increments | + | In the menu **Controller** > |
- | **# DC voltage** — current supply voltage of the Controller, in volts (**V**). | + | Wiring and connectors Compatibility: |
- | ===== Converter ===== | + | {{: |
- | In the menu section | + | **Steps** — number of encoder steps, selectable in increments of **1**. \\ **# Invert counter** |
- | {{: | + | == Debug information == |
- | **Enable** — turn on the converter mode and start charging. Select | + | **Index** — encoder index signal value. \\ **Z-Index** |
- | **Auto-enable** — allows the automatic start of charging when the charging PSU is connected to the controller. Select of values **On** and **Off**. \\ | + | ==== Motor parameters ==== |
- | **Detection threshold** — minimum voltage on phases when charger mode activates, also disables motor control, | + | Items in the **Controller** > |
- | **Battery max I** — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А** to **100.0A**, in increments of **0.5А**. \\ | + | {{: |
- | **Battery min I** — minimum charge current when current | + | **Pole pair** — the number of magnetic pole pairs of the rotor of the electric motor determines the speed at which the motor shaft will rotate. This parameter |
- | **Undercharge** — voltage relative | + | **Spin direction** — this setting allows you to change |
- | **Current drop delta** — decreases charging current down to **Battery min I** as the battery reaches maximum voltage on specified voltage range, | + | **Gear ratio** — additional motor reduction factor for motors with built-in gearbox. Simplifies setting wheel ratios for speed calculation. |
- | **Supply max I** — maximum power supply current, in amperes | + | **Integration thr.** — the analog of Hall sensors angles for sensorless motor control mode, in volts (**V**). |
- | **Supply drop U** — allowable voltage drop on wires or power supply, in volts (**V**). Select of values from **0.50 V** to **10.00 V**, in increments | + | **Control mode** — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes: \\ **Off** — control mode is disabled. \\ **Square** — outdated control method used only for motor detection. \\ **FOC** — field-oriented control |
- | **Max motor t°** — setting the limitation of the heating temperature of the motor during charging, in degrees Celsius (**°C**). Select of values from **50°C** to **120°C**, in increments | + | The control mode selected in this menu is the priority |
- | Below in the menu section, through the **#** sign, the real-time values of voltages and currents are shown: \\ | + | **Max motor U** — limits voltage supplied to the motor, in volts (**V**). In most cases, this parameter is not needed. Select of values from **0V** |
- | **# Battery I** \\ | + | |
- | **# Battery U** \\ | + | |
- | **# Supply I** \\ | + | |
- | **# Supply U** \\ | + | |
- | After plugging in the power supply, the On-board Computer will display the battery charging process. | + | **kV** |
- | {{{: | + | Next are the menu items for configuring the MTPA, this function allows you to introduce a negative id current to increase |
- | **-22.1A** — information line parameter, depending | + | |
- | **0:0:58** — time elapsed since charging started, hours, minutes, seconds. \\ | + | |
- | **I24.9** — charging current, in Amperes (**A**). \\ | + | |
- | **U53.7** — charging voltage, in Volts (**V**). \\ | + | |
- | **The indication in the middle** is the temperature | + | **Phase resistance** |
- | **Indication to the left:** \\ | + | **Inductance d** — the result of measuring the inductance of the electric motor along the d axis during auto-setup (menu item **Motor LR**), in microHenry |
- | **59.0V** — information line parameter, depending on the On-Board Computer settings. \\ | + | |
- | **15Wh** — the battery capacity in Watt hours (**Wh**). \\ | + | |
- | **100%** — the battery level, in percent | + | |
- | **I24.9** — the battery current, in Amperes | + | |
- | **U53.7** — the battery voltage, | + | |
+ | **Inductance q** — the result of measuring the inductance of the electric motor along the q axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The q-axis (" | ||
- | ~~CL~~ \\ | + | **Flux linkage** |
- | ===== I/O port configuration ===== | + | **FOC Optimization** |
- | In the **Controller** > **I/O configuration** menu section, you can configure | + | **MTPA (IPM Motor)** — enable (**On**) the MTPA function |
- | Sixteen CAN ports are additionally available | + | **FOC Vq limit** — improves field weakening |
- | {{:en: | + | **# Square wave settings:** \\ **Square offset** |
- | In the section **Controller** > **I/O configuration** > **Port state**, you can check input activation when contact shorted to GND. When a signal is applied, the value will change from **0** to **1**. Below in the menu items **# Throttle** and **# Brake** you can see the voltage on the throttle and brake levers, respectively. | + | ===== Battery ===== |
- | ~~CL~~ \\ | + | |
- | In the item ** Controller **> **I/O configuration** > **Speeds mode** you can select | + | In the **Controller** |
- | {{:en: | + | **#Quick voltage setup** |
- | Available functions for the Controller ports **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M** and CAN ports **CAN port 1** - **CAN port 16**: \\ | + | Next, select |
- | **OFF** — disable port. \\ | + | |
- | **RV** — reverse. \\ | + | |
- | **CRe** — enable cruise. \\ | + | |
- | **CR+** — increment cruise speed (when cruise | + | |
- | **CR-** — decrement cruise speed (when cruise | + | |
- | **CRr** — restore last saved cruise speed with button, activated only above min cruise speed. \\ | + | |
- | **BK** — brake button. \\ | + | |
- | **DM** — disable motor (disable throttle, brake and PAS). \\ | + | |
- | **DTH** — disable throttle. \\ | + | |
- | **DPAS** — disable PAS. \\ | + | |
- | **SWSNS** — input for Gearsensor to reduce motor torque (WIP). In development. \\ | + | |
- | **N** — activates the neutral mode forcibly, resets speed mode counter | + | |
- | **nBK** — inverted brake button input, activates the brake when the contact is opened. \\ | + | |
- | **S1** — speed 1. \\ | + | |
- | **S2** — speed 2. \\ | + | |
- | **S3** — speed 3. \\ | + | |
- | **S1of3** — speed 1 for 3-position switch. \\ | + | |
- | **S3of3** — speed 3 for 3-position switch. \\ | + | |
- | **Scyc** — cycle speed mode, sequential switching with one button. \\ | + | |
- | **S++** — increment speed, switching | + | |
- | **S--** — decrement speedи, switching | + | |
- | **SPSNS** — input for external speed sensor. \\ | + | |
- | **Spec.** — special port function (like PWM or PAS). \\ | + | |
- | Further in the menu, there are items for configuring | + | **# |
- | ~~CL~~ \\ | + | |
- | ==== PWM output setup ==== | + | |
- | To activate the **PWM P1** or **PWM P2** output, the **Controller** > **Port Setup** menu should be set to **Spec.** mode and **PAS** disabled. \\ | + | **Supply max** |
- | **PWM freq** — selection of frequency of additional PWM output on ports **P1/P2**. Select of values PWM frequency — **100Hz**, **500Hz**, **1kHz**, **5kHz**, **10kHz**, **24kHz | + | For lithium-ion (Li-ion) batteries, the minimum can be considered |
- | **PWM P1** and **PWM Р2** — selection | + | <WRAP center round important 60%> We guarantee stable operation |
- | | + | |
- | * **Stop-light** — activated when the brake is pressed. \\ | + | |
- | * **Headlight** — activated when the controller is enabled. \\ | + | |
- | * **t°C motor** — activated beyond the two deltas of the motor temperature, | + | |
- | * **t°C controller** — activated from 40°С, maximum value at 80°С temperature of the Controller. \\ | + | |
- | **PWM Pn Min** / **Max** — indicates the output range of the PWM (duty), select of values from **0%** to **100%**, in increments | + | **Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes (**А**). Select |
- | **PWM Pn t° Min** / **t° Max** — selection of motor or controller temperature, | + | |
- | ===== Extra parameters ===== | + | **Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** |
- | In the menu section | + | **Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** |
- | ==== The power button and auto shutdown ==== | + | **# DC voltage** |
- | The controller power button is located on the back of the On-Board Computer. In the **Controller** > **Extra parameters** > **Disable button** menu item, you can select the way to turn on/off the Controller, which turns on when it is powers-up or the button contacts are closed. In the off mode, the controller consumes about 100 μA, so if you reconnect the power supply without discharging the capacitors, the controller may not start. \\ | + | ===== Converter ===== |
- | {{: | + | In the menu section **Controller** |
- | Selecting modes for **Disable button**: \\ | + | {{:en:controller:k21_en.png? |
- | **None** — the controller | + | |
- | **Switch** — the controller turns on when the power button is closed (when EN shorted to GND), turns off when it opens. \\ | + | |
- | **Button** — the controller turns on the button on the On-Board Computer, press it for 2 seconds, and release, to disable it, press and hold the button again. \\ | + | |
- | **CAN** — the controller turns on when it is powers-up or the button contacts shorts, disables only when another device on CAN bus will send a request to disable. This function is used when there are several controllers on a system, where one of them is set to button or switch mode, and the other in CAN mode. \\ | + | |
- | **Auto shutdown** — activation of the controller shutdown function after a while if the motor does not spin. Select of values **On** and **Offл**. The shutdown time is set in item **Sleep time**. \\ | + | **Enable** — turn on the converter mode and start charging. Select of values **On** |
- | **Sleep time** — selection | + | **Auto-enable** — allows the automatic start of charging |
- | **Lock at turn-on** — the function locks controller inputs when enabled until the password is entered | + | **Detection threshold** — minimum voltage |
- | ==== Speedometer setup ==== | + | **Battery max I** — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А** |
- | The next block of settings | + | **Battery min I** — minimum charge current when current is decreased by voltage, |
- | {{: | + | **Undercharge** |
- | **Speed calculation** — enabling speed calculation in the Controller. Useful for multi-motor configurations, | + | **Current drop delta** — decreases charging current down to **Battery min I** as the battery reaches maximum voltage |
- | **Circumference** — wheel circumference, in millimeters | + | **Supply max I** — maximum power supply current, in amperes |
- | **Motor sprocket** — this setting specifies the number of sprocket teeth on the motor (notional), which allows you to set the gear ratio from motor shaft to the wheel. Also, this setting can be used as a reduction ratio for gear motors. \\ | + | **Supply drop U** — allowable voltage drop on wires or power supply, in volts (**V**). Select of values |
- | **Wheel sprocket** — the number | + | **Max motor t°** — setting |
- | If you have a wheel motor, then in the section | + | **MPPT** — enables and disables |
- | ==== Master-controller ==== | + | Below in the menu section, through the **#** sign, the real-time values of voltages, currents and power are shown: \\ **# Battery I** \\ **# Battery U** \\ **# Charging power** \\ **# Supply I** \\ **# Supply U** |
- | {{: | + | After plugging in the power supply, |
- | In the menu section **Controller** > **Extra parameters** > **Master-controller** you can enable | + | |
- | ~~CL~~ \\ | + | |
- | ==== Other settings | + | {{: |
- | {{: | + | **The indication in the middle** |
- | **Limit t° CPU** — limiting | + | |
- | ** Device ID** — setting | + | **Indication to the left:** \\ **59.0V** — information line parameter, depending on the On-Board Computer settings. \\ **15Wh** |
- | ~~CL~~ | + | |
- | ===== PID regulators ===== | + | ~~CL~~ |
- | In the **Controller** > **PID regulators** menu section, various signals of proportional-integral-derivative (PID) regulators are configured - devices in the control loop with feedback used in automatic control systems to generate a control signal in order to obtain the required accuracy and the quality of the transition process. **Settings for advanced users**. \\ | + | ===== I/O port configuration ===== |
- | {{: | + | In the **Controller** > |
- | Two or three coefficients are used for the settings of each regulator: \\ | + | |
- | **Ki** — integral coefficient. \\ | + | |
- | **Кp** — proportional coefficient. \\ | + | |
- | **Kd** — differentiating coefficient. \\ | + | |
- | **Square Ki, Kp** — phase current regulator for a square wave. \\ | + | Sixteen CAN ports are additionally available |
- | **FOC Ki, Kp** — phase current regulator | + | |
- | **FW Ki, Kp** — field weakening coefficients. \\ | + | |
- | **DCv Ki, Kp** — voltage regulator | + | |
- | **DCi Ki, Kp** — current regulator | + | |
- | **DCw Ki, Kp** — power calculator. \\ | + | |
- | **Speed Ki, Kp, Kd** — speed regulator for throttle control modes **Speed** and **Speed+torque**. \\ | + | |
- | **PLL Ki, Kp** — speed regulator for motor angle interpolation. \\ | + | |
- | **Acceleration Kp, Ki** — deceleration and acceleration regulator. | + | |
- | ~~CL~~ \\ | + | |
- | ===== Status flags ===== | + | |
- | The **Controller** > **Status Flags** menu section displays errors that may occur during the operation of the Controller. If an error occurs, the parameter value changes to **On**.\\ | + | {{: |
- | {{: | + | In the section **Controller** |
- | **Reset?** — reset all statuses. Values **On** and **Off**. \\ | + | If the controls are connected to the On-board computer, then it is necessary to check the activation when contact shorted to GND in the **On-board computer** > |
- | **Max acceleration** — maximum acceleration, | + | |
- | **Min deceleration** — maximum deceleration, | + | |
- | **Overload current** — the last recorded current on the phases, in Amperes. \\ | + | |
- | **Overload** — exceeding the permissible current values. Values **On** and **Off**. \\ | + | |
- | **Over-Field weakening** — weakening error. Values **On** and **Off**. \\ | + | |
- | **Supply overvoltage** — too high supply voltage, the error will appear above 95V, but in general depends on the controller model. Values | + | |
- | **Supply undervoltage** — too low supply voltage, less than the minimum battery supply threshold. Values **On** and **Off**. \\ | + | |
- | **12V protection** — breaking down or error on the 12V power line. Values **On** and **Off**. \\ | + | |
- | **Brake error** — brake lever connection error. Values **On** and **Off**. \\ | + | |
- | **Throttle error** — throttle lever connection error. Values **On** and **Off**. \\ | + | |
- | **Hall error** — Hall sensor connection error. Values **On** and **Off**. \\ | + | |
- | **Code error** — error executing firmware code. Values **On** and **Off**. Let us know if this error occurs. \\ | + | |
- | **PAS protection** — PAS error. Values **On** and **Off**. \\ | + | |
- | **Controller overheat** — overheat protection of the controller. Values **On** and **Off**. \\ | + | |
- | **Motor overheat** — overheating protection of the electric motor. Values **On** and **Off**. \\ | + | |
- | **Protection fail** — hardware error, malfunction of all protection systems during controller self-test. If this error occurs, the operation of the Controller will be impossible. Values | + | |
- | **Voltage on phases** — overvoltage on phases. Values **On** and **Off**. \\ | + | |
- | **CAN: error** — CAN-bus errors. Values **On** and **Off**. Let us know if this error occurs. \\ | + | |
- | **LEC** — types of errors on the CAN bus. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **Stuff**, **Form**, **Acknowledgment**, | + | |
- | **Receive w/error** — CAN-bus errors on receiving. \\ | + | |
- | **Sent w/error** — CAN-bus errors on transmitting. \\ | + | |
- | **CAN state** — overloading buffers. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **OVR0**, **OVR1**, **OVR01**. Tell us the code if this error occurs. \\ | + | |
- | **CPU Load** — current load of the central processor, in percentage (**%**). | + | |
- | ===== Debug information ===== | + | **# PAS An** — shows an analog PAS sensor voltage, in volts (V). |
- | The menu section **Controller** > **Debug information** shows the main parameters of your Controller, electric motor, and the whole system - temperature, | + | ~~CL~~ |
- | {{: | + | In the item ** Controller **> **I/O configuration** |
- | **Temp FET** — temperature of the field-effect transistors (MOSFETs) of the Controller, in degrees Celsius (**°C**). \\ | + | {{:en:controller:io_010623.png? |
- | **Temp Motor** — temperature of the electric motor, in degrees Celsius (**°C**). \\ | + | |
- | **DC current** — DC current, in amperes (**А**). \\ | + | |
- | **DC voltage** — DC voltage, in volts (**V**). \\ | + | |
- | **AC current** — AC current, in amperes (**А**). \\ | + | |
- | **AC voltage** — AC voltage, in volts (**V**). \\ | + | |
- | **Motor U0** — DC voltage on phases, in volts (**V**). \\ | + | |
- | **System 12V** — voltage on the CAN bus 12V, in volts (**V**). \\ | + | |
- | **System 5V** — voltage on the CAN bus 5V, in volts (**V**). \\ | + | |
- | **RPM** — motor speed, in RPM (**RPM**). \\ | + | |
- | **ERPM** — electric revolutions of the motor per minute (**ERPM**). \\ | + | |
- | **Hall input** — this parameter allows you to check the functionality of the Hall sensors. There are three digits in this item, each shows the signal level, if you rotate the motor slowly by hand, all three digits should change. If none of the digits change, check if the Hall connector is connected or the ground may be broken. If one of the digits does not change - there is no contact or the sensor wire is broken. To check the contacts in the controller, disconnect the Hall connector and measure the voltages on the controller connector. There should be about 4V on the signal lines of the Halls, 5V on the power supply, and about 3V on the temperature sensor line. \\ | + | |
- | **Hall index** — virtual position of the motor, digits from 1 to 6 (normal operation). \\ | + | |
- | **Throttle %** — the percentage of how much the throttle is pressed. \\ | + | |
- | **Brake %** — the percentage of how much the brake is pressed. \\ | + | |
- | **Speed request** — set point for the speed regulator, in eRPM. \\ | + | |
- | **Torque request** — phase current request, either positive throttle or a negative brake. \\ | + | |
- | **Torque limit** — current limit for this type of controller, taking into account overheating. \\ | + | |
- | **Temp CPU** — CPU temperature, | + | |
- | Next in the menu are the sections | + | Available functions for the Controller ports **I1**, **I2**, **I3**, **I4**, **IO5**, **IO6**, **I7**, **I8**-**I13** |
- | + | ||
- | ==== Debug FOC ==== | + | |
- | In the menu section **Controller** > **Debug information** > **Debug FOC** \\ | + | Further in the menu, there are items for configuring the PWM outputs. |
- | {{: | + | ~~CL~~ |
- | **U Q** — Q-axis voltage, in volts (**V**). \\ | + | ==== PWM output setup ==== |
- | **U D** — D-axis voltage, in volts (**V**). \\ | + | |
- | **I Q** — Q-axis current, in amperes (**А**). \\ | + | |
- | **I D** — D-axis current, in amperes (**А**). \\ | + | |
- | **Ireqest Q** — Q-axis current request, in amperes (**А**). \\ | + | |
- | **Ireqest D** — D-axis current request, in amperes (**А**). | + | |
- | ~~CL~~ \\ | + | |
- | ==== Remote inputs | + | |
- | In the menu section | + | To activate the **PWM IO5** or **PWM IO6** output, |
- | {{: | + | **PWM freq** — selection of frequency of additional PWM output |
- | **Throttle** — voltage | + | |
- | **Brake** — voltage at the brake lever at a remote source (On-board computer or uLight), in volts (**V**). \\ | + | |
- | **Throttle % **— the percentage of how much the throttle pressed at a remote source. \\ | + | |
- | **Brake %** — the percentage of how much the brake pressed at a remote source. | + | |
- | ~~CL~~ \\ | + | |
- | ===== Logger ===== | + | |
- | In the **Controller | + | **PWM IO5** |
- | {{:en:controller:k33_en.png?nolink |}} | + | * **Disabled** |
+ | * **Stop-light** | ||
+ | * **Headlight** | ||
+ | * **t°C motor** | ||
+ | * **t°C controller** | ||
+ | **PWM IOn Min** / **Max** | ||
- | **Start logging** — to start recording, select **On** and press the right button of the On-board computer. After that, the **#State** menu item will change to **Waiting** status. The recording will start automatically after pressing the throttle grip. If an error occurs during the recording process, you will see its code in the ** # Error code ** menu item. In case of an error, firstly, check that the SD card has the FAT32 file system, and secondly, that there is free space on the SD card for recording. Additionally, | + | ===== Extra parameters ===== |
- | **Stop logging** — stop recording, select **On** to end recording. | + | In the menu section |
- | ~~CL~~ \\ | + | |
- | **Start mode** — selection of recording start mode: | + | |
- | * **Manual** — enable manual recording. | + | |
- | * **At start** — recording starts automatically when the Controller | + | |
- | **Log time** — two parameters of time for recording to choose from: | + | ==== The power button and auto shutdown ==== |
- | * **Time step** — delta of time since the previous record. | + | |
- | * **Sys time** — global time, which is incremented after the start of the controller. | + | |
- | **Log rate** — delay between records | + | The controller power button is located on the back of the On-Board Computer. In the **Controller** > |
- | **Mode** — recording mode selection: | + | {{:en: |
- | * **Buffered** — buffering and recording in segments. | + | |
- | * **Max rate** — continuous recording mode. | + | |
- | **Data averaging** — using filters while recording: | + | Selecting modes for **Disable button**: \\ **None** |
- | * **None** | + | |
- | | + | |
- | | + | |
- | Next, in the **# Data to log** menu sections, you can select the set of parameters you want to record. Select **On** | + | **Auto shutdown** — activation |
- | **# Data to log**: \\ | + | **Sleep time** — selection |
- | **Battery Voltage** — battery voltage data logging. \\ | + | |
- | **Battery Current** — battery current data logging. \\ | + | |
- | **Motor Voltage** — motor voltage data logging. \\ | + | |
- | **Motor Current** — motor current data logging. \\ | + | |
- | **Wheel speed** — wheel speed data logging. \\ | + | |
- | **Throttle** — throttle grip data logging. \\ | + | |
- | **Brake** — brake lever data logging. \\ | + | |
- | **Motor rad/s** — data logging | + | |
- | **Motor RPM** — data logging of revolutions of an electric motor per minute. \\ | + | |
- | **Tmotor °C** — data logging of the electric motor temperature. \\ | + | |
- | **Tfet °C** — data logging the temperature | + | |
- | **Raw hall input** — data logging the input status | + | |
- | **Hall index** — virtual position of motor. \\ | + | |
- | **FOC Vq** — Q-axis voltage data logging. \\ | + | |
- | **FOC Vd** — D-axis voltage data logging. \\ | + | |
- | **FOC Iq** — Q-axis current data logging. \\ | + | |
- | **FOC Id** — D-axis current data logging. \\ | + | |
- | **Current phA** — data logging the current on the A phase of the electric motor. \\ | + | |
- | **Current phB** — data logging the current on the B phase of the electric motor. \\ | + | |
- | **Current phC** — data logging the current on the С phase of the electric motor. | + | |
- | ===== Device information ===== | + | **Lock at turn-on** |
- | In the menu section **Controller** > **Device Information** you can view the basic information about the Controller. In this menu, you can check which firmware version is loaded into your Controller, as well as other parameters that differ depending on the Controller model. \\ | + | ==== Speedometer setup ==== |
- | {{:en:controller:k34_en.png? | + | The next block of settings in the menu section **Controller** |
- | **Micro Nucular Controller** — device name depending on the type of Controller. \\ | + | {{:en: |
- | **Max supply** — 95V. The warranty covers supply voltages up to **90V** inclusive. \\ | + | |
- | **Max current** — the value of the maximum phase current, depending on the type of Controller, in amperes (A). \\ | + | |
- | **Firmware date** — firmware compilation date. \\ | + | |
- | **Firmware ver.** — version of the installed firmware, you can check for updates in the section **[[en:firmware|Firmware]]**. \\ | + | |
- | **Loader date** — the data loader compilation date. \\ | + | |
- | **Loader version** — data loader version. \\ | + | |
- | **Worked** — operating time of the Controller in kilowatt-hours (kW*h). \\ | + | |
- | **t° middle 100 h** — the average temperature of the Сontroller over the last 100 hours. \\ | + | |
- | **t° middle** — the average temperature of the Сontroller over all time. \\ | + | |
- | **Current protections** — the number of triggered overcurrent protections over all time of operation of the controller. | + | |
- | **Temperature protections** — the number of triggered temperature protections over all time of operation of the controller. \\ | + | |
- | **Voltage protections** — the number of triggered voltage protections over all time of operation of the controller. \\ | + | |
- | **Power cycle** — number of controller switching on. \\ | + | |
- | **Power-on time** — total operating time of the Controller, minutes, hours, days. | + | |
+ | **Speed calculation** | ||
+ | **Circumference** | ||
+ | **Motor sprocket** | ||
+ | **Wheel sprocket** | ||
- | ====== | + | If you have a wheel motor, then in the section **Controller** > **Motor setup** |
- | The controller | + | ==== Master-controller |
- | //Technical specifications | + | {{: |
- | ^ Parameters | + | ~~CL~~ |
- | ^Maximum power| | + | |
- | ^Nominal power| | + | |
- | ^Voltage range| | + | |
- | ^Phase current, max| 120A | 250А | 500А | | + | |
- | ^Battery current, max| | + | |
- | ^Supply out| 12В 3A ||| | + | |
- | ^Operating temperature range| | + | |
- | ^Phase wires| | + | |
- | ^Battery wires| | + | |
- | ^Hall connectors| | + | |
- | ^Wires length| | + | |
- | ^Control modes| | + | |
- | ^Protection| | + | |
- | ^Sleep current less| < | + | |
- | ^Protection class| | + | |
- | ^Size, without wires| | + | |
- | ^Weight| | + | |
- | ^Warranty| | + | |
- | //In the kit: // | + | ==== Other settings ==== |
- | | + | {{: |
- | | + | |
- | | + | |
- | | + | |
- | Phase, battery, and Hall sensors wires are supplied with connectors, depending on the type and specification of the controller | + | **Device ID** — setting |
- | // | + | **Prefix 1** and **Prefix 2** — controller name setting for multi-motor configurations. Using the prefixes together or separately, |
- | * САN-cables 0,3 and 2 meters length.\\ | + | For example, you have a 2WD scooter |
- | * Controller-side inputs for connection throttle, brakes levers directly | + | |
- | | + | |
- | ===== Connection diagram ===== | + | If you are using a 3WD drive or more, then both prefixes must be used for the controller name. For example, if the controller is driving a rear right motor, the setting will look like this: **Prefix 1** — **Rear**, **Prefix 2** — **Right**. |
- | First, connect the three phases of the electric motor. It does not matter in which order and by which color you connect the phases, the controller will automatically detect them during auto-setup. Next, connect the hall connector as shown in the diagram below. You also need to connect the throttle lever and battery power. We also recommend connecting the brake levers, as their actuation turns off the motor. A simple rule — in any incomprehensible situation, press the brake. | + | ==== Access level ==== |
- | When the power is turned on for the first time, the controller will start automatically. To enable/ | + | Four levels are available: \\ **Novice** \\ **User** \\ **Advanced** \\ **Engineer** |
- | You can find the wiring diagrams of the other devices on this [[https:// | + | Depending |
- | If you want to connect peripherals directly to the Controller, you need to order " | + | **Important note**: now after updating |
+ | ===== PID regulators ===== | ||
- | {{: | + | In the **Controller** |
- | ~~CL~~ \\ | + | |
- | ===== Connecting multiple controllers ===== | + | {{: |
- | If you want to connect two or more Controllers, you can use a CAN splitter with four ports (purchased separately) or a lighting controller [[en: | + | **Square Ki, Kp** — phase current regulator for a square wave. \\ **FOC Ki, Kp** — phase current regulator for FOC mode. \\ **FW Ki, Kp** — field weakening coefficients. \\ **DCv Ki, Kp** — voltage regulator on the DC bus. \\ **DCi Ki, Kp** — current regulator on the DC bus. \\ **DCw Ki, Kp** — power calculator. \\ **Speed Ki, Kp, Kd** — speed regulator for throttle control modes **Speed** |
- | For example, for a two-motor connection scheme, which is used on all-wheel-drive electric scooters, in addition to the second controller, you will need a CAN-splitter and one more CAN wire (there are 2, 1.2, and 0.3 meters long). Each Controller has a standard CAN-wire 1.2 m long. These wires from both controllers must be connected to a CAN-splitter, | + | ~~CL~~ |
- | <WRAP center round important 60%>\\ | + | ===== Status flags ===== |
- | Pay attention to the connection diagram. ** Do not disconnect power grounds when system wires are connected! ** | + | |
- | First connect all power wires and only then CAN wires. When disconnecting the controllers, | + | |
- | </ | + | |
- | {{: | + | The **Controller** |
+ | {{: | ||
- | ====== How to start? ====== | + | **Reset?** — reset all statuses. Values **On** |
- | After you have connected the Controller and Controls according to the diagram, you need to configure the battery parameters. For this, go to the **Settings** > **Devices** section, select the Controller in the list of devices, then go to the **Controller** > **Battery** section and specify the supply voltage range. For a detailed description, | + | ===== Debug information ===== |
- | {{: | + | The menu section **Controller** |
- | After configuring the battery, you need to run Auto-setup in the **Controller** > **Auto-setup** menu section. Ensure that the phase and battery wires are well contacted and insulated before running auto-setup. Check that the Hall sensor wire connectors are fully inserted into the mating parts. For details, see the section **Auto-setup**. After auto-setup, you need to adjust the speedometer to display the speed correctly, see the section [[en: | + | {{:en: |
- | ====== Menu navigation ====== | + | **Temp. controller** |
- | Use the On-board computer buttons to navigate through the menus. Left button — return to the previous | + | Next in the menu are the sections **Debug FOC** |
- | ===== Settings saving ===== | + | ==== Debug FOC ==== |
- | In the menu item **Controller** > **Save settings** you can save all the settings made. Press the right button of the Onboard-computer and select | + | In the menu section |
- | ===== Auto-setup ===== | + | {{: |
- | The auto-setup function | + | **U Q** — Q-axis voltage, |
- | {{: | + | ~~CL~~ |
- | The auto-setup menu starts the subprogram and shows only the process. All settings are saved under **Controller** > **Motor setup**. After restarting the Controller, all switches will be in the **Off** position. | + | ==== Remote inputs ==== |
- | Once you have specified the battery supply voltage in the **Controller** > **Battery** section, | + | In the menu section |
- | Before auto-setup | + | {{: |
- | \\ | + | |
- | <WRAP center round important 60%>\\ | + | |
- | **Be careful! Before running autotuning, check that the drive wheels | + | |
- | </ | + | |
- | If you have a throttle lever and an analog brake connected, then you need to enable Full Setup, and follow the instructions on the On-Board computer screen. The corresponding menu items will indicate when to press and release the throttle or brake lever. | + | ~~CL~~ |
- | If only one throttle lever is connected, you must independently turn on the items step-by-step: | + | ===== Logger ===== |
- | If the motor is heavy and autodetect does not happen, you can gently push it with your hand or increase the tuning current in the **Controller** > **Auto-setup** > **Setup current** section, | + | In the **Controller ** > **Logger** |
- | If the motor is rotating in the wrong direction, go to **Controller** > **Auto-setup** > **Spin direction** and change the direction of rotation. You can choose from two options **Forward** or **Invert**. A similar setting is available in the **Controller** > **Motor setup**> **Spin direction** menu. It doesn' | + | {{: |
- | If an error occurs during autotuning, see the section | + | **Start logging** |
- | ===== Firmware update ===== | + | **Stop logging** |
- | In the menu section | + | **Continuous logging** — allows |
- | {{: | + | ~~CL~~ |
- | **Import config.** — loads the settings from the file ** NCconf.cfg ** - ** NCconf9.cfg ** up to a maximum of 9 different configurations, | + | \\ **Start mode** — selection |
- | **Export config.** - saves the settings to the ** NCconf.cfg ** - ** NCconf9.cfg ** file up to a maximum of 9 different configurations, | + | |
- | **Reboot** — restarts the device. If the settings have not been saved, they will be reset.\\ \\ | + | |
- | **Reset Wh usage** — resets the accumulated number | + | |
- | **Reset stats** — resets mileage in kilometers.\\ \\ | + | |
- | **Load defaults** — after a reset, the default settings are loaded but not saved. If you restart the Controller without saving after a reset, the previous settings will be loaded.\\ \\ | + | |
- | **Erase data storage** — This function may be needed for the correct firmware update, rollback to default settings, in a situation where user actions lead to incorrect operation of the Controller. If the controller has stopped saving the settings, do a reset, wait 3 seconds, and try to save again.\\ \\ | + | |
- | **Update firmware** — starting the firmware update process. You can download the current firmware version and read the rules of update in the **[[en:firmware|Firmware]]** section. To update, download the firmware file to the root directory of the microSD card with the Fat/Fat32 file system. Insert the card with the contacts facing up into the slot on the On-Board Computer and select ** On **. When the update process is complete, a message appears on the screen **Update finished**. Press the left button and check the update version under **Controller** > **Device Information**. | + | |
- | ===== Control modes ===== | + | * **Manual** |
+ | * **At start** | ||
+ | **Log time** | ||
- | In the menu section | + | |
+ | | ||
+ | **Log rate** | ||
- | If there is no speed switch, then mode 1 is the default. If the switch is connected to the On-board computer, it is necessary to configure the On-board computer buttons in the **On-board computer** > **Button settings** menu. See section **[[en:display: | + | **Mode** — recording mode selection: |
- | ==== Modes setup ==== | + | * **Buffered** |
+ | * **Max rate** | ||
+ | **Data averaging** | ||
- | {{:en:controller:9_0.8.png?nolink |}} | + | * **None** |
+ | * **Fast** | ||
+ | * **Slow** | ||
+ | **Add header to log** — adding the name of the controller | ||
- | The ** # Current mode ** line displays | + | Next, in the **# Data to log** menu sections, you can select |
- | **N** — neutral. \\ | + | |
- | **S1** — speed 1. \\ | + | |
- | **S2** — speed 2. \\ | + | |
- | **S3** — speed 3. \\ | + | |
- | **RV** — reverse. \\ | + | |
- | Four parameters are used to configure each mode: \\ | + | {{: |
- | **Phase** — the maximum value of the phase current, in Amperes (**A**). Select | + | |
- | **Battery** — the maximum value of the battery current, in Amperes (**A**). Select of values from **2A** to **400A**, in increments of **2A**. When setting up, consider the capabilities of the connected battery and the maximum battery current of your controller type.\\ | + | ===== Statistics ===== |
- | **Power** — maximum power (discharge) of the battery, in kilowatts (**kW**). Select of values from **0.00kW** to **30.0kW**, in increments of **0.1kW**. Set to 0.0kW to disable | + | In the menu section |
- | **Speed** — maximum speed in percentage (%). Select of values from **4%** to **150%**, in increments of **2%**. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en:controller: | + | {{: |
- | ==== Electric brake setup ==== | + | **Wh used total** |
- | **Braking phase** — the value of the phase current of braking by the motor, in Amperes | + | The values below are approximate! \\ **Motor efficiency** — efficiency |
- | ==== Braking phase at speed control | + | ===== Device information ===== |
- | **Braking ph. at speed** — phase braking current during speed control, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows you to slow down when you reset the throttle stick. Works only with Direct Drive motors, without a clutch. \\ | + | In the menu section |
- | Also to use this mode should be selected: | + | {{: |
- | **Speed** or **Speed and Torque** mode in the **Controller** > **Control** > **Throttle Mode** menu item. | + | |
- | In the menu item **Controller** > **Control** > **Speed lim. at 0% throttle** enable the speed limit at 0% throttle (optional), enable if you need braking with completely released throttle. \\ | + | |
- | + | ||
- | ==== Regenerative braking setting ==== | + | |
- | + | ||
- | **Braking ph. at 0% throttle** — phase braking current with the throttle handle released, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. \\ | + | |
- | + | ||
- | This function will be active if additional modes are disabled in the **Controller** > **Advanced modes** menu section or if, with activated additional modes, in one of the menu sections **Mode S1**, **Mode S2** or **Mode S3** in menu item **Braking ph. at 0% throttle** was setup is **0A**. | + | |
- | ==== Reverse setup ==== | + | |
- | + | ||
- | **Speed reverse** — reverse speed, in percentage (%). Select of values from ** 2% ** to ** 150% **, in increments of ** 2% **. The value of this parameter determines the percentage of speed depending on the reference speed (see section **[[en: | + | |
- | + | ||
- | **Phase reverse** — the value of the reverse phase current, in Amperes (**A**). Select of values from **10A** to **500A**, in increments of **2A**.\\ | + | |
- | + | ||
- | + | ||
- | ==== Field weakening setup ==== | + | |
- | + | ||
- | **Field weakening** — the magnitude of the field weakening current, in Amperes (**A**). Select of values from **0A** to **500A**, | + | |
- | + | ||
- | <WRAP center round info 60%>\\ | + | |
- | The current of weakening creates a field that acts against the field of the permanent magnets. The superposition of these fields creates an equivalent field that is below nominal. The attenuation efficiency depends on the parameters of the motor. The best results can be obtained with IPM motors. | + | |
- | </ | + | |
- | + | ||
- | To set up the weakening, you need: | + | |
- | * for one of the control modes in the section **Controller** > **Control modes** specify a speed value greater than 100%, for example, Speed 3 is 120%. | + | |
- | * set the weakening current value in the section **Controller** > **Control modes**, you can start from 30A.\\ | + | |
- | + | ||
- | Field weakening is activated when the maximum speed is reached, the Controller adds weakening current, limiting the phase current and weakening current specified in the control mode. That is if the effective phase current is 70A, and the weakening current is set to 30A, then a minimum of 100A must be specified in the phase current settings. If the phase current increases to 80A, then only 20A will remain for weakening because 80A + 20A = 100A.\\ | + | |
- | + | ||
- | Also, the Controller will limit the speed of rotation of the motor so that its effective EMF does not exceed the maximum supply voltage of the controller (not the battery). If the motor starts twitching on the suspended wheel, then it is necessary to reduce the weakening current.\\ | + | |
- | + | ||
- | ==== Current change speed ==== | + | |
- | + | ||
- | **# Current change speed**. | + | |
- | * acceleration, | + | |
- | * braking, select of values from **50A/s** to **50000A/ | + | |
- | * shutdown, select of values from **50A/s** to **50000A/ | + | |
- | + | ||
- | Three parameters determine the rate of change of the current (smoothness). The higher the value, the faster the current build-up in the motor will occur. For conventional brake levers, it will be useful to reduce the parameter **braking** for a smoother activation of the regeneration. If the throttle response seems too slow, you need to increase the parameter **acceleration**. The parameter **shutdown** determines how quickly the current drops after throttle and brakes are released. | + | |
- | + | ||
- | ===== Advanced control modes ===== | + | |
- | + | ||
- | In the menu section **Controller** > **Advanced modes** enables the control modes and activates the advanced settings for each of these modes.\\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | To activate the control modes, select **Controller** > **Advanced modes** > **Enable add. modes** and to set **On**. \\ | + | |
- | + | ||
- | In the menu **Controller** > **Advanced modes** > **Neutral by default** you can activate the neutral mode (N) when the controller starts up, which will be active until one of the speed modes is activated. In a neutral mode, only the electric brake operates, throttle and PAS are disabled. This mode is recommended for use with speed buttons (not a switch). The function does not work with a 3-position switch (functions of the S1of3 and S3of3 ports in the **Controller** > **I/O configuration** menu). \\ | + | |
- | ~~CL~~ \\ | + | |
- | + | ||
- | Each mode has its own section in the **Controller** > **Advanced modes** > **Mode S1, Mode S2, Mode S3 ** with the following settings: \\ | + | |
- | + | ||
- | {{: | + | |
- | **Throttle mode** — selection of the operating mode of the throttle lever, read more in the section **[[en: | + | |
- | + | ||
- | **Acceleration lim.** and **Deceleration lim.** — are specified in ERPM/s, select of values from **0 ERPM/s** to **500000 ERPM/s**, in increments of **200 ERPM/s **. These settings allow you to limit the speed of acceleration or deceleration of the motor, it is convenient to use on slippery surfaces. For setting go to the **Controller** > **Status flags** section, in this menu there are two parameters that register the maximum acceleration and deceleration — **Max acceleration** and **Max deceleration**. **Reset** the values of these parameters in the same section of the menu, then you need to ride your e-bike in order to register the current dynamics of acceleration and deceleration. You can use these values as a reference and decrease them if you need to limit change speed. If the type of surface changes, for example, it becomes too slippery, then these values can be reduced until it becomes comfortable to catch the moment when the wheel loses traction. \\ | + | |
- | + | ||
- | **Braking ph. at 0% throttle** — phase braking current with the throttle handle released, in Amperes (A). Select of values from **0A** to **500A**, in increments of **2A**. This function allows regenerative braking to be initiated when the throttle is released. If **0A** is specified or additional modes are disabled in the **Controller** > **Advanced modes** section of the menu, then for the recuperation level will be used value from menu item in the **Controller** > **Control modes** > **Braking ph. at 0% throttle** menu item. | + | |
- | + | ||
- | **Revers** — reverse gear activation when the control mode is selected. Select of values **On** or **Off**. \\ | + | |
- | + | ||
- | **Cruise** — activation of the cruise function. Select of values **On** or **Off**. Convenient to use with cruise mode **Allow Throttle hold** in the menu section **Controller** > **Control** > **Cruise** > **Cruise** to enable cruise in certain modes. See section **[[en: | + | |
- | + | ||
- | **Disable motor** — completely disables motor control. Select of values **On** or **Off**. \\ | + | |
- | + | ||
- | **Disable throttle** — disable throttle control. Select of values **On** or **Off**. \\ | + | |
- | + | ||
- | **Active braking** — allow the brake to use the battery for stopping. Select of values **On** or **Off**. \\ | + | |
- | + | ||
- | **Reverse on brake** — after stopping, pressing the brake lever again activates reverse speed. Select of values **On** or **Off**. \\ | + | |
- | + | ||
- | **Speed lim. at 0% throttle** — allows limiting the speed when the throttle lever is released. Select of values **On** or **Off**. Selecting **Off** disables motor control when the throttle is released. \\ | + | |
- | + | ||
- | **Disable PAS** — disables the Pedal Assist. Select of values **On** or **Off**. \\ | + | |
- | + | ||
- | **PAS Scale** — extra PAS multiplier for tuning, decreases PAS signal for smoother control on high power modes. Select of values from **1%** to **100%**, in increments of **1%**. | + | |
- | + | ||
- | ===== Control ====== | + | |
- | In the **Controller** > **Control** menu section you can setup setting the engine controls, throttle levers, torque and PAS sensors, cruise control. | + | |
- | + | ||
- | ==== PAS and Torque sensor setup ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Control** > **Pedal Assist System** you can set up the Pedal Assist System (PAS), which connects the electric motor when pedaling. \\ | + | |
- | + | ||
- | ЧTo be able to connect the PAS system, it is necessary to order the PWM IO/PAS cable as an option. The PAS system connects to the Controller via the PWM IO/PAS wire to the **P1/P2** ports of the **USB/PWM** connector. When using a SEMPU pressure sensor, an additional signal output from the TH port of the connector **Control** is required. \\ | + | |
- | + | ||
- | You can look at the connecting methods of various PAS systems at **[[en: | + | |
- | + | ||
- | The PAS, unlike the Torque sensor, controls the throttle by frequency and not by the force of rotation. The PAS setup menu consists of the following items: \\ | + | |
- | + | ||
- | {{: | + | |
- | **PAS** — selection of pedaling assistant type **PAS sensor** or **Torque sensor**. If there is no PAS system, select **Disabled**.\\ | + | |
- | + | ||
- | **PAS connection** — 1-wire or 2-wire connection option, two wires are used for the angle sensor (encoder). \\ | + | |
- | **Invert PAS** — change of direction in case of 2-wire connection. Select of values **On** or **Off**. \\ | + | |
- | **PAS poles** — number of impulses per pedal revolution. Select of values from **1** to **200**, in increments of **1**.\\ | + | |
- | **PAS min. freq.** — the minimum pedal speed (cadence) at which the motor starts, RPM. Select of values from **1 RPM** to **500 RPM**, in increments of **1 RPM**. \\ | + | |
- | **PAS max freq.** — the maximum pedal speed (cadence) at which the motor starts, RPM. Select of values from **10 RPM** to **1000 RPM**, in increments of **5 RPM**. \\ | + | |
- | + | ||
- | **# PAS freq.** — the value of the signal coming from the PAS in real-time. \\ | + | |
- | **PAS timeout** — the time after which the motor turns off after stopping pedaling, in seconds (s). Select of values from **0.02s** to **5.00s**, in increments of **0.02s**. \\ | + | |
- | **PAS filter** — smoothing the control signal for smoother operation, in hertz (Hz). Select of values from **1 Hz** to **100 Hz**, in increments of **1 Hz**. \\ | + | |
- | **PAS min out** — minimum control level when PAS is running, in percent (%). Select value from **0%** to **100%**, in increments of **1%**. \\ | + | |
- | **PAS max out** — maximum control level, in percent (%). Select of values from **0%** to **100%**, in increments of **1%**. By analogy with the “pressed” throttle, PAS sends a signal within the specified limits. \\ | + | |
- | + | ||
- | Further in the menu are the settings related to the pressure sensor (Torque sensor).\\ | + | |
- | + | ||
- | **Pressure scale** — in Newton-meters/ | + | |
- | **Zero pressure** — zero pressure, in millivolts (mV). Select of values from **0mV** to **10000mV**, | + | |
- | | + | |
- | **Torque averaging** — period for which is torque value updated. Measured in half turns (turn/2). If the torque sensor measures only one pedal, then the period must be a multiple of two. Select of values from **1 turn/2** to **20 turn/2**, in increments of **1 turn/2**. \\ | + | |
- | + | ||
- | **# Torque** — shows the current torque at the sensor, in Newton-meters (Nm). \\ | + | |
- | + | ||
- | **# Human watt** — shows the average power you develop when pedaling, in watts (W). \\ | + | |
- | **Human watt min** — the minimum power you develop to activate the motor, in watts (W). Select of values from **0 W** to **500 W**, in increments of **10 W**. \\ | + | |
- | **Human watt max** — the maximum power for 100% activation, in watts (W). Select of values from **0 W** to **1000 W**, in increments of **10 W**. \\ | + | |
- | + | ||
- | **Torque min** — the torque at which the throttle signal starts to increase, Newton-meters (Nm). Select of values from **0 Nm** to **100 Nm**, in increments of **2 Nm**. All values less than this level is 0% of throttle. \\ | + | |
- | **Torque max** — the torque, which limits the level of 100% throttle, Newton-meters (Nm). Select of values from **0 Nm** to **300 Nm**, in increments of **2 Nm**. \\ | + | |
- | **Instant Torque** — allows torque sensor activation without rotation. Select of values **On** or **Off**. The pressure sensor also includes frequency configuration and output level configuration as well as the usual PAS. | + | |
- | + | ||
- | ==== Remote control ==== | + | |
- | + | ||
- | The **Controller** > **Control** > **RC Control** menu section allows you to configure the remote control of the Controller using an external RC receiver. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Input for radio control via PWM (PWM), connects to the **P1** port of the **USB/PWM** connector on the Controller board. To activate the function, select the **PWM** value in the **P1 Input Mode** menu item. \\ | + | |
- | + | ||
- | The **# Input Freq.** and **# Width** menu items show the current signal value in hertz (**Hz**) and milliseconds (**ms**), respectively. \\ | + | |
- | + | ||
- | In the menu item **Function** selects the control function — **Off**, **Throttle**, | + | |
- | ~~CL~~ \\ | + | |
- | Adjust the throttle and/or brake range as indicated by the signal.\\ | + | |
- | + | ||
- | **# Throttle range** \\ | + | |
- | **Throttle min** — minimum throttle value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ | + | |
- | **Throttle max** — maximum throttle value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ | + | |
- | + | ||
- | **# Brake range** \\ | + | |
- | **Brake min** — minimum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. \\ | + | |
- | **Brake max** — maximum brake value, in milliseconds (ms). Select of values from **0.00 ms** to **10.00 ms**, in increments of **0.01 ms**. | + | |
- | + | ||
- | ==== Cruise control setup ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Control** > **Cruise** you can set up the cruise control function. After connecting buttons or switches for cruise control to the ports of the Controller or Onboard Computer, you need to configure the functions that relate to cruise control: | + | |
- | + | ||
- | **CRe** — cruise activation. \\ | + | |
- | **CR+** — increase cruise speed (when active). \\ | + | |
- | **CR-** — decrease cruise speed (when active). \\ | + | |
- | **CRr** — restoring cruise (turning on the last saved speed). \\ | + | |
- | + | ||
- | For more information about configuring these functions, read the **[[en: | + | |
- | + | ||
- | {{: | + | |
- | In the **Cruise** menu item, you can select several control modes: \\ | + | |
- | **Disabled** — cruise control disabled. \\ | + | |
- | **Button** — activation of cruise control at the push of a button. The response time of the button is determined by the parameter **Cruise EN time**. \\ | + | |
- | **Switch** — activation of cruise control by turning on the switch, time is not used. \\ | + | |
- | **Throttle hold** — activation of cruise control by holding the throttle for a certain time in one position. The response time is determined by the parameter **Cruise EN time**. The accuracy is set by the parameter **Cruise by throttle** in percent (%). Select of values from **1%** to **30%**, in increment of **1%**. Accuracy is essential, as the throttle lever moves slightly during the ride due to shaking. The default is **2%**. \\ | + | |
- | **Allow Throttle hold** — similar to the previous mode, with the difference that to activate the cruise control, you must additionally press the cruise button. \\ | + | |
- | + | ||
- | Next are the menu items for setting the cruise: | + | |
- | + | ||
- | **Cruise restore** — this function activates the last saved cruise speed. To enable, select the **CRr** function when configuring **[[en: | + | |
- | + | ||
- | **Cruise EN time** — setting the cruise activation delay in seconds after enabled button (**s**). Select of values from **0.25s** to **30.00s**, in increments **0.25s**. \\ | + | |
- | + | ||
- | **Cruise level** — selects what speed cruise will use: \\ | + | |
- | * **Throttle** — speed depends on the position of the throttle lever, turns on instantly. \\ | + | |
- | * **Speed** — cruise enables when **Safe acceleration** reached after that uses current speed as a reference. \\ | + | |
- | * **Mixed** — if controller cant use speed reference, uses throttle value. \\ | + | |
- | + | ||
- | **Cruise smoothness** — this setting limits acceleration during cruising so that there are no jerks, measured in electrical revolutions per minute per second (ERPM/s). To get the value in rpm, the ERPM/s value must be divided by the number of pole pairs of the electric motor. Select of values from **0 ERPM/s** to **50000 ERPM/s**, in increments of **50 ERPM/s**. \\ | + | |
- | + | ||
- | **# Used for cruise activation**: | + | |
- | **Safe acceleration** — limits the acceleration at which the cruise is activate, for example, to prevent it from engaging when accelerating, | + | |
- | **Min. speed** — speed below which you can not activate cruise or recovery, in kilometers per hour (km/h). Select of values from **3 km/h** to **127 km/h**, in increments of **1 km/h**.\\ | + | |
- | + | ||
- | Additionally, | + | |
- | + | ||
- | What actions disable cruise control: | + | |
- | * pressing the brake, analog or digital. | + | |
- | * repeated throttle press. | + | |
- | * if a switch is used — when it's disabled. | + | |
- | * reverse enable. | + | |
- | + | ||
- | + | ||
- | ==== Throttle and brake curves setup ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Control** > **Throttle/ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | You can select the following types of throttle and brake presets: \\ | + | |
- | **Linear** — smooth increase, direct dependence. \\ | + | |
- | **Exponential** — slow increase. \\ | + | |
- | **Normal** — average between linear and exponential. \\ | + | |
- | **Polynomial** — average between normal and exponential. \\ | + | |
- | + | ||
- | Manual setting of throttle and brake position points is also available, to do this select **None** in **Throttle preset** or **Brake preset** and enter the value manually. There are eight position points available for throttle and brake:: \\ | + | |
- | **Start** — starting point, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ | + | |
- | **1**-**6** — midpoints, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ | + | |
- | **End** — end point, in percentages (%). Select of values from **0%** to **100%**, in increments of **1%**. \\ | + | |
- | + | ||
- | You can also manually edit the value of each point in the loaded preset. | + | |
- | ~~CL~~ \\ | + | |
- | ==== Control source ==== | + | |
- | + | ||
- | The controller supports the connection of controls (throttle, brake, switches, and buttons) to the Controller, On-board computer, ulight board, or mixed connection when one part of the periphery is connected to the Controller, and the second part to the On-board computer, or to ulight and On-board computer. This is necessary in the case of Tork/PAS sensor configurations in the Controller + throttle lever in the On-board computer. In the menu item **Controller** > **Control** > **Control Source** you can set up the control source of the Controller`s. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Select of control options: \\ | + | |
- | **Auto** — all sources will control the Сontroller. Built-in and external, connected via CAN bus (for example, On-board computer or ulight). \\ | + | |
- | **Embedd** — only what is connected directly to the Сontroller. \\ | + | |
- | **Remote** — control only via CAN bus (via On-board computer or Microlight). \\ | + | |
- | **Disabled** — disables any control of the Controller. | + | |
- | ~~CL~~ \\ | + | |
- | + | ||
- | ==== Throttle control mode setup ==== | + | |
- | + | ||
- | The menu item **Controller** > **Control** > **Throttle mode** you can set up throttle lever mode. | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Three throttle modes options are available: | + | |
- | **Speed** — a similar mode is used in Infineon controllers and non-programmable low-cost controllers and is characterized by the use of maximum current to reach a given speed. In this mode, the maximum thrust is used until the desired speed is reached, the thrust is not regulated by the throttle grip. \\ | + | |
- | **Torque** — in this mode, the throttle controls phase current, the thrust is limited by the angle of rotation of the throttle. \\ | + | |
- | **Speed+torque** — combined mode (as Kelly), similar to the operation of the gas pedal in a car with an internal combustion engine. \\ | + | |
- | + | ||
- | In the case of selecting the **Speed+torque** mode, pressing throttle to 50%, when achieved 50% speed, the current consumption will be reduced to hold speed. The acceleration current will also be proportionally lower. \\ | + | |
- | ==== Throttle and brake voltage range setup ==== | + | |
- | + | ||
- | The menu items in the **Controller** > **Control** section allow you to set the voltage ranges of the throttle and brake grips. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Currently, voltage settings for all throttles and brakes are common. \\ | + | |
- | **# Throttle** — shows the voltage of throttle grip connected to the controller, in volts (V). \\ | + | |
- | **Throttle min** and **Throttle max** — range of the throttle grip, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. If the maximum value is exceeded by 5%, protection against a broken throttle grip will be activated. If the range is incorrectly set, then when you fully press the throttle grip, the electric motor will turn off, in this case, you need to increase the range value. \\ | + | |
- | + | ||
- | **# Brake** — shows the voltage of the brake connected to the controller, in volts (V). \\ | + | |
- | **Brake min** and **Brake max** — range of the analog brake lever, in millivolts (mV). Select of values from **0 mV** to **15 000 mV**, in increments of **10 mV**. \\ | + | |
- | + | ||
- | **Brake button power** — braking force when pressing the brake button relative to the phase braking level, in percent (%). This setting allows you to adjust the level of braking force with the brake levers with integrated brake buttons. \\ | + | |
- | **Invert brake** — inverts the voltage value from the built-in brake lever. Select **On** to enable. It is useful to enable when the voltage brake lever with reverse voltage is connected to the On-board computer and you want to use the value **Auto** in the menu item **Controller** > **Control** > **Control source**. The digital brake grip (i.e. button) connects to the On-board computer, see section **[[en: | + | |
- | **Active braking** — enables brake to use the battery for stopping. Select of values **On** and **Off**. \\ | + | |
- | **Brake at overheat** — enables full torque braking when motor overheated. Select of values **On** and **Off**. \\ | + | |
- | **Reverse on brake** — after stopping, pressing the brake lever again activates reverse. Select of values **On** and **Off**. | + | |
- | ==== Setup 100% speed value ==== | + | |
- | + | ||
- | The menu items in the **Controller** > **Control** section allow you to adjust the 100% speed level. The maximum speed in the field weakening mode is 150%. | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Speed ref. filter** — filter mode selection. Select of values **OFF**, **Linear**, **Quadratic**, | + | |
- | + | ||
- | **Filter factor** — sets the filtration factor. Select of values from **0** to **30000**, in increments of **100**. \\ | + | |
- | + | ||
- | **Speed mode** allows you to select the level of 100% speed and what it depends on: \\ | + | |
- | * **OFF** — completely disables speed control PID. \\ | + | |
- | * **Middle U bat** — the average value between the minimum and maximum voltage of the battery settings used as speed reference, depending on motor kV. \\ | + | |
- | * **U supply** — supply voltage used as speed reference, depending on motor kV. \\ | + | |
- | * **Ref. speed** — speed in km/h, is set by parameter **Reference speed**. The speed value is taken from the motor or from an external speed sensor connected to the controller. \\ | + | |
- | * **Ref. ERPM** — speed in motor electric RPM, is set by parameter **Reference speed**. \\ | + | |
- | + | ||
- | **Minimum speed** — in electrical revolutions per minute (ERPM). Select of values from **0 ERPM** to **100000 ERPM**, in increments of **100 ERPM**. | + | |
- | + | ||
- | **Speed lim. at 0% throttle** — enables limiting the speed when the throttle grip is completely released. Select of values **On** and **Оff**. Selecting **Off** disables motor control when the throttle is released. | + | |
- | + | ||
- | ===== Motor setup ===== | + | |
- | + | ||
- | The **Controller** > **Motor Setup** menu contains all settings related to electric motor operation parameters. | + | |
- | + | ||
- | ==== Motor temperature sensor ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Motor setup** > **Motor t°-sensor** you can select a temperature range in which a smooth power limit will occur (**Delta °t** parameter) and specify the maximum temperature (**°t max**). | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **°t max** — maximum electric motor temperature, | + | |
- | **Delta °t** — the temperature value that is deducted from the maximum temperature (**°t max**), the resulting temperature value will be the beginning of the power limit, in degrees Celsius (°C). Select of values from **1°C** to **100°C**, in increments of **1 °C**. \\ | + | |
- | + | ||
- | In the menu item **Sensor type** you can select the following types of temperature sensors that support the controller — **KTY81(82)**, | + | |
- | + | ||
- | It is recommended to install a temperature sensor so close as possible on the stator windings, while not in contact with the stator iron. If you don't know what kind of sensor is in the motor, you can check all types of sensors and select the one that displays data the most closely to room temperature. The current measured temperature is displayed at **# Value °t #**. \\ | + | |
- | + | ||
- | The **# °t R (+-10%)#** menu item displays the resistance of the motor temperature sensor, with an accuracy of +/-10%. | + | |
- | + | ||
- | ==== Clutch ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Motor Setup** > **Clutch** you can configure a smooth engine launch for soft engagement clutch or freewheel. Useful for gear motors or mid-drives. At the moment, the setting works well only in the control mode **Torque**, because the clutch there is always engaged. An alternative option is to configure the acceleration limit in the modes **S1**, **S2**, **S3** in the menu section **Controller** > **Advanced modes**. | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | The parameter **Mode** determines the way of operation:: \\ | + | |
- | **Accelerate** — smoothly accelerates the motor until the load appears. \\ | + | |
- | **Accelerate and hold** — in addition to the previous one, it applies weak torque to the motor after the throttle is released, this mode allows you to switch speeds at mid-drive systems without using the pedals. \\ | + | |
- | + | ||
- | **# Phase amps** \\ | + | |
- | **Start time** — maximum time for soft start, in seconds (s). Select values from **1s** to **20s**, in increments of **1s**. \\ | + | |
- | **Start current** — phase motor current at which the load will be detected and the soft start is disabled, in amperes (А). Select values from **0.2А** to **50.0А**, in increments of **0.2А**. This value must be higher than the phase current for specified acceleration of the motor without load. \\ | + | |
- | **Detection time** — the time during which the load must be present, after which the soft start will be switched off, in milliseconds (ms). Select values from **10 ms** to **1000 ms**, in increments of **10 ms**. \\ | + | |
- | **Acceleration** — value in volts/ | + | |
- | **Hold (20%)** and **Hold (80%)** — two parameters regulating the phase current supplied to the motor in the mode **Accelerate and hold**, in amperes (А). **20%** — current at low speeds, **80%** — current at about maximum speed. It is possible to determine the approximate values by the no-load current of the motor. Select values from **0.2А** to **50.0А**, in increments of **0.2А**. \\ | + | |
- | **Hold enable time** — time through which after the throttle has been pressed, torque hold will become available, in seconds (s). Select values from **1s** to **120s**, in increments of **4s**. \\ | + | |
- | + | ||
- | **Hold time** — the time during which torque will be applied after releasing the throttle, in seconds (s). Select values from **1s** to **120 s**, in increments of **1s**. \\ | + | |
- | + | ||
- | <WRAP center round tip 60%>\\ Optimal settings for MAC motor: **Accelerate**, | + | |
- | + | ||
- | ==== Hall sensors setup ==== | + | |
- | + | ||
- | Under the menu section **Controller** > **Motor setup** > **Position sensors**, you can find the menu items for configuring the Hall sensors of the electric motor. | + | |
- | + | ||
- | === Manual setup the Hall sensors angles === | + | |
- | + | ||
- | In general, it is not recommended to change these settings manually!\\ | + | |
- | In the menu section **Controller** > **Motor settings** > **Manual angle setup** you can set up the Hall sensors angles of the electric motor. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Offset for square** — additional shift for square wave mode, in degrees (**°**). Select of values from **-30°** to **30°**, in increments of **1°**. \\ | + | |
- | **Offset total fwd** — shift all Halls sensors by the specified value for the direct rotation of the motor, in degrees (**°**). Select of values from **-60°** to **60°**, in increments of **1°**. \\ | + | |
- | **Offset total bkwd** — shift all Halls sensors by the specified value for the reverse rotation of the motor., in degrees (**°**). Select of values from **-60°** to **60°**, in increments of **1°**. \\ | + | |
- | + | ||
- | To shift all the halls, you must press the right button of the On-board computer, enter the shift angle, press the right button again. The value will be reset and the angle of all halls will change to the specified value. You can change the angle of the hall shift in the opposite direction by setting a negative value. \\ | + | |
- | + | ||
- | **Reset angles** — reset of all Hall sensors angles. Select of values **On** and **Off**. \\ | + | |
- | **Integration threshold** — analogue of Hall angles for sensorless engine control mode, in volts (**V**). \\ | + | |
- | **Hall adjust Ki** — the meaning of the coefficient is to find the midpoint of the position of the Hall sensors when adjusting them. Values from **0.02** to **5.00**, in increments of **0.02**. If the value of the coefficient is too small, then the tuning process will end before the midpoint is determined. If the value of the coefficient is too large, then the setting will not be completed and will stop by timeout, because the midpoint will not be found due to the angles changing too often. | + | |
- | + | ||
- | === Hall table === | + | |
- | + | ||
- | The **Controller** > **Motor Setup** > **Hall table** menu section shows the Hall indices and Hall angles for the two directions of rotation of the electric motor. These indices are used for the internal operation of the Controller. \\ | + | |
- | + | ||
- | {{: | + | |
- | ~~CL~~ \\ | + | |
- | + | ||
- | === Advanced Hall sensor settings === | + | |
- | + | ||
- | Further in the menu section **Controller** > **Motor Setup** > **Position sensor** there are items for additional setting of Hall sensors. | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Sensor type** — currently, by default, only one type of **Hall** sensor is available. Additional types of supported sensors will be added in future updates. | + | |
- | + | ||
- | **Sensor mode** — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes: \\ | + | |
- | **Sensorless** — motor control using BEMF integration, | + | |
- | **Combined** — start the motor on Hall sensors, then switch to sensorless mode, the threshold is determined by the parameter radians per second (**rad/s**) in the **From hall to s-less** menu item. Select of values from **0.00 rad/s** to **2.00 rad/s** in increments of **0.05 rad/s**. To convert values keep in mind that 1 rad/s to RPM = 9.5493 RPM. \\ | + | |
- | **Sensors** — electric motor control only by signals from Hall sensors. \\ | + | |
- | **Freq** — frequency control. Do not use this mode for driving! \\ | + | |
- | + | ||
- | **Interpolate halls** — smooth change of the Hall sensors angle based on speed. Used for FOC mode. Select of values **On** and **Off**. \\ | + | |
- | + | ||
- | **Interpolation start** — the motor is always started from a discrete angle, if digital halls are used. After the specified speed, the angle starts to change smoothly. Select of values from **0 rad/s** to **100 rad/s**, in increments of **1 rad/s**. \\ | + | |
- | + | ||
- | **Frequency control** — a separate mode that can be used to power equipment through a transformer or to dry the varnish on the motor windings. Select of values from **10 HZ** to **200 HZ**, in increments of **1 HZ**. \\ | + | |
- | + | ||
- | **Hall filter** — enable or disable the filter in the direction of rotation, select the **Direction** and **OFF** values.\\ | + | |
- | + | ||
- | **State filter** — select the delay time, in seconds (sec). Selection of values from **0.000s** to **1.000s**, in increments of **0.002s**. This delay is used if the wrong value of the Hall sensors is received. All indicators that are less than the set value will be filtered out. \\ | + | |
- | + | ||
- | **Direction filter** — select the delay time for changing the direction of rotation of the electric motor (forward/ | + | |
- | + | ||
- | ==== Motor parameters ==== | + | |
- | + | ||
- | Items in the **Controller** > **Motor setup** menu section allow you to configure the parameters of the electric motor. | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Pole pair** — the number of pole pairs of the stator winding of the electric motor determines the speed at which the motor shaft will rotate. This parameter is used to calculate RPM and speed. For a more accurate autodetection of the Hall sensors angles, you must specify the correct value for the number of pole pairs for your motor. For the most popular motors, you can see this value in the table **[[en: | + | |
- | + | ||
- | **Spin direction** — this setting allows you to change the direction of rotation of the electric motor. Select of values **Forward** and **Invert**. Or you can swap two motor phases to change the direction of rotation.\\ | + | |
- | + | ||
- | **Integration thr.** — the analog of Hall sensors angles for sensorless motor control mode, in volts (**V**). \\ | + | |
- | + | ||
- | **Control mode** — this parameter is loaded at start-up and can be saved. At the moment, the Controller has the following motor control modes: \\ | + | |
- | **Off** — control mode is disabled.\\ | + | |
- | **Square** — outdated control method used only for motor detection. \\ | + | |
- | **FOC** — field-oriented control of the motor. \\ | + | |
- | **DC-DC** — charging mode when you use the controller in motor charging mode. \\ | + | |
- | + | ||
- | The control mode selected in this menu is the priority setting for the controller. If the Hall sensor mode is selected in the **Controller** > **Motor setup** > **Position sensor** menu, which does not correspond to the set operating mode of the electric motor, then this Hall sensor mode will be automatically replaced with a more suitable one. | + | |
- | + | ||
- | **Max motor U** — limits voltage supplied to the motor, in volts (**V**). In most cases, this parameter is not needed. Select of values from **0V** to **100V**, in increments of **1V**. \\ | + | |
- | + | ||
- | **kV** — motor parameter, electric revolutions per volt (**eRPM/ | + | |
- | + | ||
- | Next are the menu items for configuring the MTPA, this function allows you to introduce a negative id current to increase the torque on the IPM motors. | + | |
- | + | ||
- | **Phase resistance** — the result of measuring the phase resistance of the electric motor during auto-setup (menu item **Motor LR**), in Ohms (Ohm). \\ | + | |
- | + | ||
- | **Inductance d** — the result of measuring the inductance of the electric motor along the d axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The d-axis (" | + | |
- | + | ||
- | **Inductance q** — the result of measuring the inductance of the electric motor along the q axis during auto-setup (menu item **Motor LR**), in microHenry (µH). The q-axis (" | + | |
- | + | ||
- | **Flux linkage** — is the total magnetic flux permeating the electrical circuit, in Weber (Wb). \\ | + | |
- | + | ||
- | **# Square wave settings:** \\ | + | |
- | **Square offset** — additional shift for square wave mode, in degrees (°). Select of values from -30° to 30°, in increments of 1°. This item is similar to the same item in the menu **Controller** > **Motor setup** > **Position sensor** > **Manual angle setup**. \\ | + | |
- | **Boost square current** — in the sensorless or square mode, applies 100% PWM at the beginning of each winding switch. Starting from specified speed and minimum requested current. Select of values **On** and **Off**. \\ | + | |
- | **Boost current** — setting refers to the control mode **Square**, the minimum current from which the rapid current pumping in the windings is turned on, in amperes (**А**). Select of values from **0A** to **100A**, in increments of **1A**. \\ | + | |
- | **Boost speed** — setting refers to the control mode **Square**, the minimum speed after which the rapid pumping of current in the windings is turned on, in radians per second (**rad/ | + | |
- | + | ||
- | + | ||
- | ===== Battery ===== | + | |
- | + | ||
- | In the **Controller** > **Battery** menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V** to **90V**, this is **21S** for Lithium-ion (Li-ion) batteries and **25S** for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[en: | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Full charge** — delta voltage relative to the maximum, at which when the controller is turned on, will reset the watt-hour consumption, | + | |
- | + | ||
- | **Supply max** and **Supply min** — battery voltage range, in volts (**V**). Select values from **20.00V** to **95.00V**, in increments of **00.1V**. Also, these settings are used for the **Converter** mode. \\ | + | |
- | + | ||
- | For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**. \\ | + | |
- | For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**. \\ | + | |
- | + | ||
- | <WRAP center round important 60%> | + | |
- | We guarantee stable operation of the Controller at voltages up to **90V** inclusive. Using a battery over 90V may damage the Controller and void the warranty. | + | |
- | </ | + | |
- | + | ||
- | + | ||
- | **Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes (**А**). Select values from **1.0A** to **400.0А**, | + | |
- | + | ||
- | **Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** to **400.0А**, | + | |
- | + | ||
- | **Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** to **30000 W**, in increments of **100W**. | + | |
- | + | ||
- | **# DC voltage** — current supply voltage of the Controller, in volts (**V**). | + | |
- | + | ||
- | ===== Converter ===== | + | |
- | + | ||
- | In the menu section **Controller** > **Converter**, | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Enable** — turn on the converter mode and start charging. Select of values **On** and **Off**. \\ | + | |
- | + | ||
- | **Auto-enable** — allows the automatic start of charging when the charging PSU is connected to the controller. Select of values **On** and **Off**. \\ | + | |
- | + | ||
- | **Detection threshold** — minimum voltage on phases when charger mode activates, also disables motor control, in volts per phase (**Vph**). Select of values from **10Vph** to **80Vph**, in increments of **1Vph**. \\ | + | |
- | + | ||
- | **Battery max I** — maximum battery charge current, if no value is specified then battery settings are used, in amperes (**А**). Select of values from **0.0А** to **100.0A**, in increments of **0.5А**. \\ | + | |
- | + | ||
- | **Battery min I** — minimum charge current when current is decreased by voltage, in amperes (**А**). Select of values from **0.5А** to **10.0A**, in increments of **0.5А**. \\ | + | |
- | + | ||
- | **Undercharge** — voltage relative to maximum battery voltage setup, in volts (**V**). Let's decrease the full charge voltage. Select of values from **0.00V** to **10.0V**, in increments of **0.1V**. \\ | + | |
- | + | ||
- | **Current drop delta** — decreases charging current down to **Battery min I** as the battery reaches maximum voltage on specified voltage range, in volts (**dV**). Select of values from **0.0dV** to **20.0 dV** in increments of **0.5 dV**. | + | |
- | + | ||
- | **Supply max I** — maximum power supply current, in amperes (**А**). Select of values from **2.0 A** to **150.0 A**, in increments of **0.5 A**. | + | |
- | + | ||
- | **Supply drop U** — allowable voltage drop on wires or power supply, in volts (**V**). Select of values from **0.50 V** to **10.00 V**, in increments of **0.25 V**. \\ | + | |
- | + | ||
- | **Max motor t°** — setting the limitation of the heating temperature of the motor during charging, in degrees Celsius (**°C**). Select of values from **50°C** to **120°C**, in increments of **5°C**. \\ | + | |
- | + | ||
- | Below in the menu section, through the **#** sign, the real-time values of voltages and currents are shown: \\ | + | |
- | **# Battery I** \\ | + | |
- | **# Battery U** \\ | + | |
- | **# Supply I** \\ | + | |
- | **# Supply U** \\ | + | |
- | + | ||
- | After plugging in the power supply, the On-board Computer will display the battery charging process. | + | |
- | + | ||
- | {{{: | + | |
- | **-22.1A** — information line parameter, depending on the On-Board Computer settings. \\ | + | |
- | **0:0:58** — time elapsed since charging started, hours, minutes, seconds. \\ | + | |
- | **I24.9** — charging current, in Amperes (**A**). \\ | + | |
- | **U53.7** — charging voltage, in Volts (**V**). \\ | + | |
- | + | ||
- | **The indication in the middle** is the temperature of the motor and the controller, respectively, | + | |
- | + | ||
- | **Indication to the left:** \\ | + | |
- | **59.0V** — information line parameter, depending on the On-Board Computer settings. \\ | + | |
- | **15Wh** — the battery capacity in Watt hours (**Wh**). \\ | + | |
- | **100%** — the battery level, in percent (**%**). \\ | + | |
- | **I24.9** — the battery current, in Amperes (**A**). \\ | + | |
- | **U53.7** — the battery voltage, in Volts (**V**). \\ | + | |
- | + | ||
- | + | ||
- | ~~CL~~ \\ | + | |
- | + | ||
- | ===== I/O port configuration ===== | + | |
- | + | ||
- | In the **Controller** > **I/O configuration** menu section, you can configure the ports functions. The controller has eight digital ports that can be configured for different functions — **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M**. See section **[[en: | + | |
- | + | ||
- | Sixteen CAN ports are additionally available **CAN port 1** - **CAN port 16**, the signal source for which can be configured on the On-board computer or uLight. These are software values, there are fewer physical inputs on the boards, at the moment there are eight CAN ports **IO1** - **IO8** available in the On-board computer plus four Hotkeys (buttons on the On-board computer). In the future, six CAN ports ** I1 ** - ** I6 ** will be added to the uLight board. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | In the section **Controller** > **I/O configuration** > **Port state**, you can check input activation when contact shorted to GND. When a signal is applied, the value will change from **0** to **1**. Below in the menu items **# Throttle** and **# Brake** you can see the voltage on the throttle and brake levers, respectively. | + | |
- | ~~CL~~ \\ | + | |
- | + | ||
- | In the item ** Controller **> **I/O configuration** > **Speeds mode** you can select the method for switching additional modes **S1**, **S2**, **S3** for inputs in the Controller or CAN inputs - **Switch** or **Buttons**. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Available functions for the Controller ports **S1**, **S3**, **RV**, **CR**, **P1**, **P2**, **P**, **M** and CAN ports **CAN port 1** - **CAN port 16**: \\ | + | |
- | **OFF** — disable port. \\ | + | |
- | **RV** — reverse. \\ | + | |
- | **CRe** — enable cruise. \\ | + | |
- | **CR+** — increment cruise speed (when cruise is active). \\ | + | |
- | **CR-** — decrement cruise speed (when cruise is active). \\ | + | |
- | **CRr** — restore last saved cruise speed with button, activated only above min cruise speed. \\ | + | |
- | **BK** — brake button. \\ | + | |
- | **DM** — disable motor (disable throttle, brake and PAS). \\ | + | |
- | **DTH** — disable throttle. \\ | + | |
- | **DPAS** — disable PAS. \\ | + | |
- | **SWSNS** — input for Gearsensor to reduce motor torque (WIP). In development. \\ | + | |
- | **N** — activates the neutral mode forcibly, resets speed mode counter if used. If neutral is activated by default, you need to change speed mode again to exit neutral. \\ | + | |
- | **nBK** — inverted brake button input, activates the brake when the contact is opened. \\ | + | |
- | **S1** — speed 1. \\ | + | |
- | **S2** — speed 2. \\ | + | |
- | **S3** — speed 3. \\ | + | |
- | **S1of3** — speed 1 for 3-position switch. \\ | + | |
- | **S3of3** — speed 3 for 3-position switch. \\ | + | |
- | **Scyc** — cycle speed mode, sequential switching with one button. \\ | + | |
- | **S++** — increment speed, switching the speed from low to high with one button. \\ | + | |
- | **S--** — decrement speedи, switching the speed from high to low with one button. \\ | + | |
- | **SPSNS** — input for external speed sensor. \\ | + | |
- | **Spec.** — special port function (like PWM or PAS). \\ | + | |
- | + | ||
- | Further in the menu, there are items for configuring the PWM outputs. | + | |
- | ~~CL~~ \\ | + | |
- | ==== PWM output setup ==== | + | |
- | + | ||
- | To activate the **PWM P1** or **PWM P2** output, the **Controller** > **Port Setup** menu should be set to **Spec.** mode and **PAS** disabled. \\ | + | |
- | + | ||
- | **PWM freq** — selection of frequency of additional PWM output on ports **P1/P2**. Select of values PWM frequency — **100Hz**, **500Hz**, **1kHz**, **5kHz**, **10kHz**, **24kHz (FAN)**. For a conventional light bulb, large values are not needed. Select the frequency **100Hz**, this will be enough to avoid flickering. The high frequency marked ** FAN ** is used to control the fan, this is their standard frequency. \\ | + | |
- | + | ||
- | **PWM P1** and **PWM Р2** — selection of operating modes: \\ | + | |
- | * **Disabled** — mode not selected. \\ | + | |
- | * **Stop-light** — activated when the brake is pressed. \\ | + | |
- | * **Headlight** — activated when the controller is enabled. \\ | + | |
- | * **t°C motor** — activated beyond the two deltas of the motor temperature, | + | |
- | * **t°C controller** — activated from 40°С, maximum value at 80°С temperature of the Controller. \\ | + | |
- | + | ||
- | **PWM Pn Min** / **Max** — indicates the output range of the PWM (duty), select of values from **0%** to **100%**, in increments **1%**. \\ | + | |
- | **PWM Pn t° Min** / **t° Max** — selection of motor or controller temperature, | + | |
- | + | ||
- | ===== Extra parameters ===== | + | |
- | + | ||
- | In the menu section **Controller** > **Extra parameters** you can set up various additional settings of the Controller. | + | |
- | + | ||
- | ==== The power button and auto shutdown ==== | + | |
- | + | ||
- | The controller power button is located on the back of the On-Board Computer. In the **Controller** > **Extra parameters** > **Disable button** menu item, you can select the way to turn on/off the Controller, which turns on when it is powers-up or the button contacts are closed. In the off mode, the controller consumes about 100 μA, so if you reconnect the power supply without discharging the capacitors, the controller may not start. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Selecting modes for **Disable button**: \\ | + | |
- | **None** — the controller turns on when it is power-up up or when the power button is closed, does not turn off. \\ | + | |
- | **Switch** — the controller turns on when the power button is closed (when EN shorted to GND), turns off when it opens. \\ | + | |
- | **Button** — the controller turns on the button on the On-Board Computer, press it for 2 seconds, and release, to disable it, press and hold the button again. \\ | + | |
- | **CAN** — the controller turns on when it is powers-up or the button contacts shorts, disables only when another device on CAN bus will send a request to disable. This function is used when there are several controllers on a system, where one of them is set to button or switch mode, and the other in CAN mode. \\ | + | |
- | + | ||
- | **Auto shutdown** — activation of the controller shutdown function after a while if the motor does not spin. Select of values **On** and **Offл**. The shutdown time is set in item **Sleep time**. \\ | + | |
- | + | ||
- | **Sleep time** — selection of the controller shutdown time when the **Auto shutdown** function is activated, in seconds, (**s**). Select of values from **30s** to **1500s**, in increments of **5s**. \\ | + | |
- | + | ||
- | **Lock at turn-on** — the function locks controller inputs when enabled until the password is entered on the On-Board Computer, if there is no On-Board Computer, enabling this setting will permanently lock the controller. | + | |
- | + | ||
- | ==== Speedometer setup ==== | + | |
- | + | ||
- | The next block of settings in the menu section **Controller** > **Extra parameters** refers to the speed calculation setting. If you use an external speed sensor connected to the On-board computer, you need to configure it in menu **[[en: | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Speed calculation** — enabling speed calculation in the Controller. Useful for multi-motor configurations, | + | |
- | + | ||
- | **Circumference** — wheel circumference, | + | |
- | + | ||
- | **Motor sprocket** — this setting specifies the number of sprocket teeth on the motor (notional), which allows you to set the gear ratio from motor shaft to the wheel. Also, this setting can be used as a reduction ratio for gear motors. \\ | + | |
- | + | ||
- | **Wheel sprocket** — the number of teeth of the wheel sprocket, similar to the setting **Motor sprocket**. \\ | + | |
- | + | ||
- | If you have a wheel motor, then in the section **Controller** > **Motor setup** you need to specify the number of **Pole pair** (divide the number of magnets by two). For gear motors or mid-drives, it is recommended to install an external speed sensor that connects to the Onboard computer or to any of the controller ports. | + | |
- | + | ||
- | ==== Master-controller ==== | + | |
- | + | ||
- | {{: | + | |
- | In the menu section **Controller** > **Extra parameters** > **Master-controller** you can enable the function of controlling other controllers from the current one. This setting is suitable for multi-motor configurations where control (throttle, brake and etc.) is connected into one of the controllers directly. | + | |
- | ~~CL~~ \\ | + | |
- | + | ||
- | ==== Other settings ==== | + | |
- | + | ||
- | {{: | + | |
- | **Limit t° CPU** — limiting the temperature of the processor, in degrees Celsius (**°C**). When the specified threshold is reached, the phase current will be limited. Select of values from **60°C** to **105°C**, in increments of **5°C**. \\ | + | |
- | + | ||
- | **Device ID** — setting the Controller number in the CAN network. This number is displayed in the menu section **Settings** > **Devices** in front of each device that is connected to the network using the [[en: | + | |
- | + | ||
- | **Prefix 1** and **Prefix 2** — controller name setting for multi-motor configurations. Using the prefixes together or separately, you can specify where the electric motor that the Controller controls is located. The selectable values for each prefix are **None**, **Front**, **Rear**, **Left**, **Right**. To save the setting, go to the **Controller** > **Save settings** menu item and select **On**, then restart the controller. The prefix will now appear in front of the controller name in the **Devices** menu. \\ | + | |
- | + | ||
- | For example, you have a 2WD scooter and two 12F controllers, | + | |
- | + | ||
- | If you are using a 3WD drive or more, then both prefixes must be used for the controller name. For example, if the controller is driving a rear right motor, the setting will look like this: **Prefix 1** — **Rear**, **Prefix 2** — **Right**. \\ | + | |
- | + | ||
- | ===== PID regulators ===== | + | |
- | + | ||
- | In the **Controller** > **PID regulators** menu section, various signals of proportional-integral-derivative (PID) regulators are configured - devices in the control loop with feedback used in automatic control systems to generate a control signal in order to obtain the required accuracy and the quality of the transition process. **Settings for advanced users**. \\ | + | |
- | + | ||
- | {{: | + | |
- | Two or three coefficients are used for the settings of each regulator: \\ | + | |
- | **Ki** — integral coefficient. \\ | + | |
- | **Кp** — proportional coefficient. \\ | + | |
- | **Kd** — differentiating coefficient. \\ | + | |
- | + | ||
- | **Square Ki, Kp** — phase current regulator for a square wave. \\ | + | |
- | **FOC Ki, Kp** — phase current regulator for FOC mode. \\ | + | |
- | **FW Ki, Kp** — field weakening coefficients. \\ | + | |
- | **DCv Ki, Kp** — voltage regulator on the DC bus. \\ | + | |
- | **DCi Ki, Kp** — current regulator on the DC bus. \\ | + | |
- | **DCw Ki, Kp** — power calculator. \\ | + | |
- | **Speed Ki, Kp, Kd** — speed regulator for throttle control modes **Speed** and **Speed+torque**. \\ | + | |
- | **PLL Ki, Kp** — speed regulator for motor angle interpolation. \\ | + | |
- | **Acceleration Kp, Ki** — deceleration and acceleration regulator. | + | |
- | ~~CL~~ \\ | + | |
- | ===== Status flags ===== | + | |
- | + | ||
- | The **Controller** > **Status Flags** menu section displays errors that may occur during the operation of the Controller. If an error occurs, the parameter value changes to **On**.\\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Reset?** — reset all statuses. Values **On** and **Off**. \\ | + | |
- | **Max acceleration** — maximum acceleration, | + | |
- | **Min deceleration** — maximum deceleration, | + | |
- | **Overload current** — the last recorded current on the phases, in Amperes. \\ | + | |
- | **Overload** — exceeding the permissible current values. Values **On** and **Off**. \\ | + | |
- | **Over-Field weakening** — weakening error. Values **On** and **Off**. \\ | + | |
- | **Supply overvoltage** — too high supply voltage, the error will appear above 95V, but in general depends on the controller model. Values **On** and **Off**. \\ | + | |
- | **Supply undervoltage** — too low supply voltage, less than the minimum battery supply threshold. Values **On** and **Off**. \\ | + | |
- | **12V protection** — breaking down or error on the 12V power line. Values **On** and **Off**. \\ | + | |
- | **Brake error** — brake lever connection error. Values **On** and **Off**. \\ | + | |
- | **Throttle error** — throttle lever connection error. Values **On** and **Off**. \\ | + | |
- | **Hall error** — Hall sensor connection error. Values **On** and **Off**. \\ | + | |
- | **Code error** — error executing firmware code. Values **On** and **Off**. Let us know if this error occurs. \\ | + | |
- | **PAS protection** — PAS error. Values **On** and **Off**. \\ | + | |
- | **Controller overheat** — overheat protection of the controller. Values **On** and **Off**. \\ | + | |
- | **Motor overheat** — overheating protection of the electric motor. Values **On** and **Off**. \\ | + | |
- | **Protection fail** — hardware error, malfunction of all protection systems during controller self-test. If this error occurs, the operation of the Controller will be impossible. Values **On** and **Off**. \\ | + | |
- | **Voltage on phases** — overvoltage on phases. Values **On** and **Off**. \\ | + | |
- | **CAN: error** — CAN-bus errors. Values **On** and **Off**. Let us know if this error occurs. \\ | + | |
- | **LEC** — types of errors on the CAN bus. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **Stuff**, **Form**, **Acknowledgment**, | + | |
- | **Receive w/error** — CAN-bus errors on receiving. \\ | + | |
- | **Sent w/error** — CAN-bus errors on transmitting. \\ | + | |
- | **CAN state** — overloading buffers. If everything is alright you will see the value **Ok**. In case of errors, there will be values - **OVR0**, **OVR1**, **OVR01**. Tell us the code if this error occurs. \\ | + | |
- | **CPU Load** — current load of the central processor, in percentage (**%**). | + | |
- | + | ||
- | ===== Debug information ===== | + | |
- | + | ||
- | The menu section **Controller** > **Debug information** shows the main parameters of your Controller, electric motor, and the whole system - temperature, | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Temp FET** — temperature of the field-effect transistors (MOSFETs) of the Controller, in degrees Celsius (**°C**). \\ | + | |
- | **Temp Motor** — temperature of the electric motor, in degrees Celsius (**°C**). \\ | + | |
- | **DC current** — DC current, in amperes (**А**). \\ | + | |
- | **DC voltage** — DC voltage, in volts (**V**). \\ | + | |
- | **AC current** — AC current, in amperes (**А**). \\ | + | |
- | **AC voltage** — AC voltage, in volts (**V**). \\ | + | |
- | **Motor U0** — DC voltage on phases, in volts (**V**). \\ | + | |
- | **System 12V** — voltage on the CAN bus 12V, in volts (**V**). \\ | + | |
- | **System 5V** — voltage on the CAN bus 5V, in volts (**V**). \\ | + | |
- | **RPM** — motor speed, in RPM (**RPM**). \\ | + | |
- | **ERPM** — electric revolutions of the motor per minute (**ERPM**). \\ | + | |
- | **Hall input** — this parameter allows you to check the functionality of the Hall sensors. There are three digits in this item, each shows the signal level, if you rotate the motor slowly by hand, all three digits should change. If none of the digits change, check if the Hall connector is connected or the ground may be broken. If one of the digits does not change - there is no contact or the sensor wire is broken. To check the contacts in the controller, disconnect the Hall connector and measure the voltages on the controller connector. There should be about 4V on the signal lines of the Halls, 5V on the power supply, and about 3V on the temperature sensor line. \\ | + | |
- | **Hall index** — virtual position of the motor, digits from 1 to 6 (normal operation). \\ | + | |
- | **Throttle %** — the percentage of how much the throttle is pressed. \\ | + | |
- | **Brake %** — the percentage of how much the brake is pressed. \\ | + | |
- | **Speed request** — set point for the speed regulator, in eRPM. \\ | + | |
- | **Torque request** — phase current request, either positive throttle or a negative brake. \\ | + | |
- | **Torque limit** — current limit for this type of controller, taking into account overheating. \\ | + | |
- | **Temp CPU** — CPU temperature, | + | |
- | + | ||
- | Next in the menu are the sections **Debug FOC** and **Remote inputs**, which are described below. | + | |
- | + | ||
- | ==== Debug FOC ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Debug information** > **Debug FOC** \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **U Q** — Q-axis voltage, in volts (**V**). \\ | + | |
- | **U D** — D-axis voltage, in volts (**V**). \\ | + | |
- | **I Q** — Q-axis current, in amperes (**А**). \\ | + | |
- | **I D** — D-axis current, in amperes (**А**). \\ | + | |
- | **Ireqest Q** — Q-axis current request, in amperes (**А**). \\ | + | |
- | **Ireqest D** — D-axis current request, in amperes (**А**). | + | |
- | ~~CL~~ \\ | + | |
- | ==== Remote inputs ==== | + | |
- | + | ||
- | In the menu section **Controller** > **Debug information** > **Remote inputs** you can view the parameters of the throttle and brake levers connected to other devices connected to the CAN-bus (On-board computer or uLight). \\ | + | |
- | + | ||
- | {{: | + | |
- | **Throttle** — voltage on the throttle lever at a remote source (On-board computer or uLight), in volts (**V**). \\ | + | |
- | **Brake** — voltage at the brake lever at a remote source (On-board computer or uLight), in volts (**V**). \\ | + | |
- | **Throttle % **— the percentage of how much the throttle pressed at a remote source. \\ | + | |
- | **Brake %** — the percentage of how much the brake pressed at a remote source. | + | |
- | ~~CL~~ \\ | + | |
- | ===== Logger ===== | + | |
- | + | ||
- | In the **Controller ** > **Logger** menu section, you can enable and configure the data logging during the operation of the Controller. This functionality is experimental, | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Start logging** — to start recording, select **On** and press the right button of the On-board computer. After that, the **#State** menu item will change to **Waiting** status. The recording will start automatically after pressing the throttle grip. If an error occurs during the recording process, you will see its code in the ** # Error code ** menu item. In case of an error, firstly, check that the SD card has the FAT32 file system, and secondly, that there is free space on the SD card for recording. Additionally, | + | |
- | + | ||
- | **Stop logging** — stop recording, select **On** to end recording. | + | |
- | ~~CL~~ \\ | + | |
- | **Start mode** — selection of recording start mode: | + | |
- | * **Manual** — enable manual recording. | + | |
- | * **At start** — recording starts automatically when the Controller is turned on. | + | |
- | + | ||
- | **Log time** — two parameters of time for recording to choose from: | + | |
- | * **Time step** — delta of time since the previous record. | + | |
- | * **Sys time** — global time, which is incremented after the start of the controller. | + | |
- | + | ||
- | **Log rate** — delay between records of values. You can choose either the number of PWM cycles (**PWM1**, **PWM2**, **PWM5**, **PWM10**), either time (**1ms**, **10ms**, **20ms**, **100ms**, **1s**, **5s**, **10s**, **30s**). | + | |
- | + | ||
- | **Mode** — recording mode selection: | + | |
- | * **Buffered** — buffering and recording in segments. | + | |
- | * **Max rate** — continuous recording mode. | + | |
- | + | ||
- | **Data averaging** — using filters while recording: | + | |
- | * **None** | + | |
- | * **Fast** — slight averaging (smoothes values). | + | |
- | * **Slow** — large averaging. | + | |
- | + | ||
- | Next, in the **# Data to log** menu sections, you can select the set of parameters you want to record. Select **On** to enable parameter recording. | + | |
- | + | ||
- | {{: | + | |
- | **# Data to log**: \\ | + | |
- | **Battery Voltage** — battery voltage data logging. \\ | + | |
- | **Battery Current** — battery current data logging. \\ | + | |
- | **Motor Voltage** — motor voltage data logging. \\ | + | |
- | **Motor Current** — motor current data logging. \\ | + | |
- | **Wheel speed** — wheel speed data logging. \\ | + | |
- | **Motor rad/s** — data logging of the angular speed of the electric motor. \\ | + | |
- | **Motor RPM** — data logging of revolutions of an electric motor per minute. \\ | + | |
- | **Tmotor °C** — data logging of the electric motor temperature. \\ | + | |
- | **Tfet °C** — data logging the temperature of field-effect transistors. \\ | + | |
- | **Raw hall input** — data logging the input status from Hall sensors without filter. \\ | + | |
- | **Hall index** — virtual position of motor. \\ | + | |
- | **Throttle %** — throttle grip data logging. \\ | + | |
- | **Brake %** — brake lever data logging. \\ | + | |
- | **FOC Vq** — Q-axis voltage data logging. \\ | + | |
- | **FOC Vd** — D-axis voltage data logging. \\ | + | |
- | **FOC Iq** — Q-axis current data logging. \\ | + | |
- | **FOC Id** — D-axis current data logging. \\ | + | |
- | **FOC Iq request** — Q-axis current request data logging. \\ | + | |
- | **FOC Id request** — D-axis current request data logging. \\ | + | |
- | **Current phA** — data logging the current on the A phase of the electric motor. \\ | + | |
- | **Current phB** — data logging the current on the B phase of the electric motor. \\ | + | |
- | **Current phC** — data logging the current on the С phase of the electric motor. \\ | + | |
- | **PAS frequency RPM** — PAS frequency data logging. \\ | + | |
- | **PAS torque Nm** — PAS torque data logging. \\ | + | |
- | **PAS power W** — PAS power data logging. \\ | + | |
- | **Speed request** — speed request data logging. \\ | + | |
- | **Torque request** — torque request data logging.\\ | + | |
- | + | ||
- | ===== Statistics ===== | + | |
- | + | ||
- | In the menu section **Controller** > **Statistics** you can view the data on the Controller. These are trip statistics that will be automatically reset when the controller is powered off. If you have several Controllers in the system, then you can see the summary data for all controllers in the general statistics in the On-board computer. \\ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | **Wh used total** — total energy consumption (used plus regen), in Watt-hours (**Wh**). \\ | + | |
- | **Wh used** — energy consumption, | + | |
- | **Wh regen.** — energy gained during the recuperation process, in Watt-hours (**Wh**). \\ | + | |
- | **Regen. %** — the percentage of energy recovered during recuperation (**%**). \\ | + | |
- | **Ah used total** — total energy consumption (used plus regen), in Ampere hours (**Ah**). | + | |
- | **Ah used** | + | |
- | **Ah regen.** — energy gained during the recuperation process, in Ampere hours (**Ah**). \\ | + | |
- | + | ||
- | The values below are approximate! \\ | + | |
- | **Motor efficiency** — efficiency of the electric motor, in percent (**%**). \\ | + | |
- | **Eff. average** — average efficiency of the electric motor, in percent (**%**). \\ | + | |
- | **Torque** — current torque of the electric motor, in Newton-meters (**Nm**). \\ | + | |
- | **Power out** — the power that the electric motor delivers, in Watts (**W**). \\ | + | |
- | **Power in** — power supplied to the electric motor, in Watts (**W**). \\ | + | |
- | ===== Device information ===== | + | |
- | In the menu section | + | **Nucular |
- | {{: | ||
- | **Micro Nucular Controller** — device name depending on the type of Controller. \\ | ||
- | **Max supply** — 95V. The warranty covers supply voltages up to **90V** inclusive. \\ | ||
- | **Max current** — the value of the maximum phase current, depending on the type of Controller, in amperes (A). \\ | ||
- | **Firmware date** — firmware compilation date. \\ | ||
- | **Firmware ver.** — version of the installed firmware, you can check for updates in the section **[[en: | ||
- | **Loader date** — the data loader compilation date. \\ | ||
- | **Loader version** — data loader version. \\ | ||
- | **Worked** — operating time of the Controller in kilowatt-hours (kW*h). \\ | ||
- | **t° middle 100 h** — the average temperature of the Сontroller over the last 100 hours. \\ | ||
- | **t° middle** — the average temperature of the Сontroller over all time. \\ | ||
- | **Current protections** — the number of triggered overcurrent protections over all time of operation of the controller. \\ | ||
- | **Temperature protections** — the number of triggered temperature protections over all time of operation of the controller. \\ | ||
- | **Voltage protections** — the number of triggered voltage protections over all time of operation of the controller. \\ | ||
- | **Power cycle** — number of controller switching on. \\ | ||
- | **Power-on time** — total operating time of the Controller, minutes, hours, days. |