en:controller:setup [2026/04/20 10:44]
vasilisk [Status flags]
en:controller:setup [2026/09/03 07:35] (current)
vasilisk [Battery]
Line 502: Line 502:
 ===== Battery ===== ===== Battery =====
  
-In the **Controller**  > **Battery**  menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V**  to **90V**, this is **21S**  for Lithium-ion (Li-ion) batteries and **25S**  for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[:en:display:start#battery_capacity|settings]] of On-board Computer. If you use several batteries with different parameters on the same bike, you can save the configurations for each battery on the SD card and load them after replacing the battery. The SD card can be stored in the On-board computer.+In the **Controller** > **Battery** menu section you can set up the parameters of the battery connected to the Controller. The Nucular controllers support supply voltages from **20V** to **90V**, this is **21S** for Lithium-ion (Li-ion) batteries and **25S** for Lithium-iron-phosphate (LiFePO4) batteries. To configure the battery, you must specify the range of supply voltage and current. To correctly display the battery capacity on the On-board computer screen and correctly calculate the remaining charge, you must specify the battery capacity in [[:en:display:start#battery_capacity|settings]] of On-board Computer. If you use several batteries with different parameters on the same bike, you can save the configurations for each battery on the SD card and load them after replacing the battery. The SD card can be stored in the On-board computer.
  
-**#Quick voltage setup**  — feature to help you select the correct parameters for your battery. To automatically configure the items **Full charge****Supply max****Supply min**you need to select the type of battery chemistry from the following options: \\ **LiIon (3.6V)**  for li-ion battery\\ **LFP (3.2V)**  for lithium-iron-phosphate battery (LiFePO4). \\ **LTO (2.3V)**  for lithium-titanate battery (Li4Ti5O12).+<WRAP center round tip 60%> Controller estimates remaining battery charge from Wh consumption (energy drawn by the controller), not from battery voltageVoltage-based estimation is inaccurate — voltage fluctuates with loadtemperatureand chemistry in a non-linear waymaking it an unreliable indicator of actual remaining capacity. Because the percentage is calculated from cumulative Wh usage since the last full charge, it does not update upward during a partial chargeThe system recalibrates (resets to 100%only when the battery reaches 100% at the moment of power-on. If you charge from, say, 40% to 70%, the display will continue showing 40% until the next full charge and power cycle</WRAP>
  
-Next, select the **Cell count**, values from **8S**  to **28S**, in increments of **1S**. After thatin the **Apply setup**  item, select **Yes**. After saving the settings, you will see a window with new battery parametersIt is important to remember that we guarantee the operation of controllers with voltages up to 90VThe device is technically rated for 95V, but operating above 90V will void the warranty and you will be warned about this in a pop-up windowFor example, if you try to select 22S for lithium-ion battery. If the settings exceed 95V, the controller will also warn you that you are trying to set the voltage too high.+**#Quick voltage setup** — feature to help you select the correct parameters for your battery. To automatically configure the items **Full charge**, **Supply max**, **Supply min**, you need to select the type of battery chemistry from the following options:\\ 
 +**LiIon (3.6V)** for li-ion battery.\\ 
 +**LFP (3.2V)** for lithium-iron-phosphate battery (LiFePO4).\\ 
 +**LTO (2.3V)** for lithium-titanate battery (Li4Ti5O12).
  
-**#Limits:**  section \\ **Full charge**  — delta voltage relative to the maximum, at which when the controller is turned on, will reset the watt-hour consumption, in volts (**dV**)This setting resets the **From charge statistics**  when the Controller is turned on. Select values from **0.00 dV**  to **10.00 dV**, in increments of **0.3 dV**.+Next, select the **Cell count**, values from **8S** to **28S**, in increments of **1S**. After that, in the **Apply setup** item, select **Yes**. After saving the settings, you will see a window with new battery parameters. It is important to remember that we guarantee the operation of controllers with voltages up to 90VThe device is technically rated for 95Vbut operating above 90V will void the warranty and you will be warned about this in a pop-up windowFor example, if you try to select 22S for a lithium-ion battery. If the settings exceed 95V, the controller will also warn you that you are trying to set the voltage too high.
  
-**Supply max**  and **Supply min**  — battery voltage range, in volts (**V**). Select values from **20.00V**  to **95.00V**, in increments of **0.1V**. Also, these settings are used for the **Converter**  mode.+**#Limits:** section\\ 
 +**Full charge** — delta voltage relative to the maximum, at which when the controller is turned on, will reset the watt-hour consumption, in volts (**dV**). This setting resets the **From charge statistics** when the Controller is turned on. Select values from **0.00 dV** to **10.00 dV**, in increments of **0.3 dV**.
  
-For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**. \\ For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**.+**Supply max** and **Supply min** — battery voltage range, in volts (**V**). Select values from **20.00V** to **95.00V**, in increments of **0.1V**. Also, these settings are used for the **Converter** mode.
  
-<WRAP center round important 60%> We guarantee stable operation of the Controller at voltages up to **90V**  inclusive. Using a battery over 90V may damage the Controller and void the warranty</WRAP>+For lithium-ion (Li-ion) batteries, the minimum can be considered **2.8V*S**, the maximum **4.2V*S**.\\ 
 +For lithium-iron-phosphate (LiFePO4)-minimum **2.7V*S**, maximum **3.6V*S**.
  
-**Charge max**  — maximum battery charging current, during regeneration or in **Converter**  mode, in amperes (**А**). Select values from **1.0A**  to **400.0А**, in increments of **0.5А**.+<WRAP center round important 60%> We guarantee stable operation of the Controller at voltages up to **90V** inclusiveUsing a battery over 90V may damage the Controller and void the warranty</WRAP>
  
-**Discharge max**  — maximum continuous discharge current of the batterybut in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A**  to **400.0А**, in increments of **0.5А**.+**Charge max** — maximum battery charging current, during regeneration or in **Converter** mode, in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**.
  
-**Power max**  — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W**  to **30000 W**, in increments of **100W**.+**Discharge max** — maximum continuous discharge current of the battery, but in boost mode, it can be more, check (Throttle control mode setup.), in amperes (**А**). Select values from **1.0A** to **400.0А**, in increments of **0.5А**. 
 + 
 +**Power max** — maximum continuous discharge power, in watts (**W**). Set 0W to deactivate power limit. Select values from **0W** to **30000 W**, in increments of **100W**
 + 
 +**# DC voltage** — current supply voltage of the Controller, in volts (**V**).
  
-**# DC voltage**  — current supply voltage of the Controller, in volts (**V**). 
  
 ===== Converter ===== ===== Converter =====