meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
en:ulight [2022/04/18 10:05]
dmitry [Inputs configuration]
en:ulight [2022/04/18 10:12]
dmitry [Inputs configuration]
Line 54: Line 54:
 ~~CL~~ \\ ~~CL~~ \\
 ==== Inputs configuration ==== ==== Inputs configuration ====
-The functions of inputs **I1-I6 **  (see diagram above) are selected in the **Function setup**  section. Two temperature sensors can be connected to uLight. \\+The functions of inputs **I1-I6 **  (see diagram above) are selected in the **Function setup**  section. Two thermal sensors can be connected to uLight. \\
      
 {{:en:ulight_2en.jpg?nolink&241x142 |}} {{:en:ulight_2en.jpg?nolink&241x142 |}}
-**T-sensor T1 type** — selection of **NTC10K3950**  or **NTC10K3380**  temperature sensor. Select **Off**  if no sensor is connected. \\ +**T-sensor T1 type** — selection of **NTC10K3950**  or **NTC10K3380**  thermal sensor. Select **Off**  if no sensor is connected. \\ 
 **# T-sensor T1** — current temperature of the thermal sensor Т1 in degrees Celsius (°C). \\ **# T-sensor T1** — current temperature of the thermal sensor Т1 in degrees Celsius (°C). \\
-**T1 Threshold (port I7)** — I7 is a virtual port intended to function setup (see Function setup). Selectable values ​​from 0°C to 250°C, in 1°C increments. +**T1 Threshold (port I7)** — I7 is a virtual port intended to function setup (see Function setup). Values ​​from 0°C to 250°C, in 1°C increments. \\ 
-**T-sensor T1** — displays the temperature of the temperature sensor T1 in degrees Celsius (**°C**). \\  +**Т1 Threshold mode** — signal operation mode from the thermal sensor, selection of values ​​**Normal** (the signal state is first “off” when triggered is “on”and **Inverted** (the signal state is first “on”, when triggered is “off”). \\ 
-**T-sensor T2 type** — similar to the **T-sensor T1 type**  settings. \\  +The settings for Temperature sensor T2 are similar to those for Temperature sensor T1. \\ 
-**T-sensor T2** — similar to the settings for **T-sensor T1 type**. \\  +**CAN-Control** — this setting refers to the **THR**  (throttle), **BRK**  (brakes), **IO2**, and **IO3**  inputs on the uLight board and is used when the throttle, brakes and switches are connected directly to the uLight board. When you select the **On**  setting, control signals from the inputs will be transmitted via the CAN bus and you will be able to control the Controller from the uLight board using the throttle, brake and switch inputs. \\ 
-**CAN-Control** — this setting refers to the **THR**  (throttle), **BRK**  (brakes), **IO2**, and **IO3**  inputs on the uLight board and is used when the throttle, brakes and switches are connected directly to the uLight board. When you select the **On**  setting, control signals from the inputs will be transmitted via the CAN bus and you will be able to control the Controller from the uLight board using the throttle, brake and switch inputs.+**CAN ports** — redirecting inputs to groups of CAN ports for controlling the controller. Selectable values — **OFF**, **CAN 1-8** and **CAN 9-16**.
  
 ==== Function setup ==== ==== Function setup ====